FBO DAILY ISSUE OF APRIL 02, 2009 FBO #2684
SOURCES SOUGHT

Z -- Design Build VA SPD Suite & Kitchen Expansion - Sources Sought Response Form

Notice Date
3/31/2009
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Army, U.S. Army Corps of Engineers, U.S. Army Corps of Engineers, Detroit, 477 Michigan Avenue, Detroit, Michigan, 48226
 
ZIP Code
48226
 
Solicitation Number
W911XK-VA-SPD-Suite-FtWayneIN
 
Archive Date
4/10/2009
 
Point of Contact
Michael Freestone,, Phone: 313-226-2797
 
E-Mail Address
michael.d.freestone@usace.army.mil
 
Small Business Set-Aside
N/A
 
Description
Sources Sought Response Form This is a SOURCES SOUGHT notice. The U.S. Army Corps of Engineers, Detroit District, is seeking potential firms that have the capability to provide Design Build services as part of a construction project that shall include, but not be limited to the expansion of the Supply, Processing, and Distribution (SPD) Suite and Kitchen Modification at the Department of Veterans Affairs, Northern Indiana Health Care System - Fort Wayne Campus, Fort Wayne Indiana. Required work involves space planning, design and renovation work to expand the SPD Suite into the existing Kitchen area. Project will include installation of steam and gas sterilizers, instrument washer, ultrasonic washer, Steris I Machines, dryer, and high pressure point of use boilers (supply sterilizers). Contractor will relocate and/or provide new systems, as needed, for electrical, HVAC, plumbing, lighting and ceiling. SPD Layout shall be designed according to VA Design guides and Space planning criteria, which includes: proper mechanical rooms and exhaust routes for support equipment, HAC room to serve infection control needs of decontamination area, pass through window from decontamination area to Sterile prep area, water still, staff locker rooms with showers on both sterile and decontamination areas, proper flow for materials to be moved from pre-decontamination to post sterilization per VA Design guide and Space Planning criteria, and all support equipment. Design will expand SPD into the Kitchen area. Kitchen modifications shall be developed to keep the Kitchen functional, to include: relocating the dish machine, relocating 3 compartment sinks, removing an old refrigerator and installing new roll-in type refrigerator, preparing area to support two (2) bulk Re-Therm units, storage to support daily use and 7-day back-up food supplies, cart washer area, and other functions required to keep kitchen functional. The contract will have 12 month completion requirement. The estimated award date of the contract is 15 July 2009. The estimated cost of construction is between $ 1,000,000 and $ 5,000,000. The North American Industrial Classification System (NAICS) code is 236220, which has a size standard of $33,500,000 in average annual receipts. The project requires knowledge of "Design Build" hospital construction special needs and in particular the functions of the supply, processing, and distribution (SPD) and kitchen suites. This is NOT a request for proposal. This announcement is for planning purposes only. In order to determine the extent of industry interest and experience in the requirement, interested contractors shall present the following information: a brief overview of the firm's capabilities and experience on "Design Build" projects similar in scope and cost magnitude to this program; and any socio-economic classification(s) (e.g., large business, small business, small disadvantaged business, etc.) as they relate to NAICS code 236220. Firms must submit a letter from their bonding company related to their bonding capacity for individual projects along with their letter of interest. Qualified companies are encouraged to respond. The response to this notice shall be in summary format and shall not exceed two (2) pages. Do NOT send a SF 330. No basis for claim against the Government shall arise as a result of a response to this sources sought or Government use of any information provided. The Government will not pay for information or comments provided and will not recognize any costs associated with submission of comments. Companies or individuals interested in responding are invited to submit their information via email only to Contracting at LRE-Quotes@usace.army.mil All attachments must be provided in either Microsoft Word or Adobe Acrobat PDF format. Please send responses by no later than 2:00 PM local prevailing time at Detroit, MI on 9 Apr 09. PLEASE REFERENCE "SOURCES SOUGHT: VA Fort Wayne Hospital, FY 09 Design Build SPD Suite Expansion and Kitchen Modification in the subject line. Respondents will not be contacted regarding their submission or information gathered as a result of this Sources Sought notice. The formal solicitation, will be issued at a later date by a separate announcement. Offerors MUST be registered in www.ccr.gov under the NAICS code 236220 to be considered. Contracting Office Address: 477 Michigan Ave, 7 th Floor Detroit, MI 48226-4523
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=fd4116c29c16a75ad4fade79fb541da7&tab=core&_cview=1)
 
Place of Performance
Address: Dept of Veterans Affairs, Northern Indiana Health Care System, Ft. Wayne Campus, Ft. Wayne, Indiana, Ft Wayne, Indiana, United States
 
Record
SN01781682-W 20090402/090331221023-fd4116c29c16a75ad4fade79fb541da7 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.