Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 26, 2009 FBO #2649
DOCUMENT

66 -- Complementary metal-oxide-semiconductor (CMOS) - Technical Eval. Criteria

Notice Date
2/24/2009
 
Notice Type
Technical Eval. Criteria
 
NAICS
423410 — Photographic Equipment and Supplies Merchant Wholesalers
 
Contracting Office
Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, 5630 Fishers Lane, Room 2129, Rockville, Maryland, 20857-0001
 
ZIP Code
20857-0001
 
Solicitation Number
1052925
 
Point of Contact
Vida - Niles, Phone: 301-827-2476
 
E-Mail Address
vida.niles@fda.hhs.gov
 
Small Business Set-Aside
N/A
 
Description
Solicitation # 1052925 The Food and Drug Administration is seeking small businesses set aside that can provide offerors to submit quotes/proposals. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR 12.6, simplified acquisition procedures and the resultant purchase order will include all applicable provisions and clauses in effect through the Federal Acquisition Circular 05-24. This announcement constitutes the only solicitation and a written solicitation will not be issued. This synopsis, NAICS code 423410, is to notify contractors that the government intends to issue a Fixed Price Contract in accordance with FAR Part 13.106 for the following statement of work, under the simplified acquisition procedures. Prospective offerors are responsible for downloading the solicitation and any amendments. It is the offeror's responsibility to monitor the FedBizOpps website for the release of any amendments to this solicitation. Hard copies will be provided to individuals eligible under the Americans with Disabilities Act and Rehabilitation Act upon request. The Government reserves the right to award a contract without discussions if the Contracting Officer determines that the initial offer(s) is/are providing the Best Value and discussions are not necessary. Background: The “complementary metal-oxide-semiconductor” (CMOS) camera system shall be able to acquire high speed, high resolution, fluorescence images from cardiac tissue stained with a variety of fluorescence markers. The system shall include the CMOS camera as well as all necessary components to run the camera and acquire data to a controller PC. It is expected that a controller PC with the camera control hardware and acquisition software installed, as well as necessary cables shall be part of the system. System Requirements: The FDA requires a CMOS sensor which must contain at least 10,000 elements. They system shall be capable of acquiring 10,000 frames per second at full resolution with at least 14 bits without loss of data. The well-depth of each sensor must be at least 100,000,000 photo-electrons. The CMOS system shall allow both software and hardware triggering of the initiation of data capture. The system shall also allow for triggering capabilities to terminate a free-running data capture episode. The system must allow for continuous data acquisition to memory at 10,000 frames per second at full resolution for a minimum of 3 seconds. This corresponds to a minimum of 1 gigabyte of data memory. The system must provide an output signal (preferably TTL) signifying each frame acquisition. The system must have been shown to acquire fluorescence signals at 10,000 frames per second from excitable cardiac tissue stained with the voltage-sensitive dye di-4-ANEPPS or di-8-ANEPPS. Description: High-speed, large well size, CMOS camera system (at least 10,000 pixels that can be run at speeds up to 10 KHz full frame). The system should also be able to run at 1, 2, and 5kHz full frame. The system should include all hardware and software to record fluorescence signals and save them to a PC harddisk. QTY 1 Delivery: Time must be stated in the quote. Warranty: Warranty must be of the product explicitly stated. CCR: Vendors must be registered in the Central Contractor Register (CCR) prior to the award of a contract. You may register by going to www.ccr.gov. You will need your Tax ID, Duns Number, Bradstreet number and banking information. QUESTIONS DEADLINE: All questions are to be submitted via email to Vida.Niles@fda.hhs.gov, no later than March 5, 2009, 4:30 pm EST. QUOTATIONS DUE: All quotations are due to: Vida.Niles@fda.hhs.gov, no later than 4:30 pm, EST on Thursday, March 12, 2009. PROVISIONS and CLAUSES: The provision at FAR 52.212-1, Instructions to Offerors Commercial Items applies to this solicitation. The following agenda has been attached to this provision: None. The clause at FAR 52.212-4, Contract Terms and Conditions, Commercial Items applies to this acquisition. The following agenda has been attached to the clause: None. The clause at FAR 52.212-5 Contract Terms and Conditions Required to Implement Statues or Executive Orders, Commercial Items applies to this acquisition. The following FAR clauses cited are applicable: FAR 52.217-8, FAR 52.222-26, FAR 52.222-35, FAR 52.222-36, FAR 52.232-33, FAR 52.246-9 and FAR 52.246-18. Clauses and provisions are incorporated by reference and apply to this acquisition. Responses to this notice shall be sent via email to Vida.Niles@fda.hhs.gov, Telephone calls will not be accepted. We have the right to award without discussions.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=086762806dad4de2a7f90400d913a33d&tab=core&_cview=1)
 
Document(s)
Technical Eval. Criteria
 
File Name: Technical Evaluation Criteria (Technical Evaluation 1052925 (3).doc)
Link: https://www.fbo.gov//utils/view?id=15f77b6452efee98d02c2dbf6c502ead
Bytes: 23.50 Kb
 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: 10903 New Hampshire Avenune, Silver Spring, Maryland, 20993, United States
Zip Code: 20993
 
Record
SN01755838-W 20090226/090224220819-086762806dad4de2a7f90400d913a33d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.