SOLICITATION NOTICE
29 -- Connector,Throttle Wire
- Notice Date
- 1/14/2009
- Notice Type
- Presolicitation
- NAICS
- 336312
— Gasoline Engine and Engine Parts Manufacturing
- Contracting Office
- Defense Logistics Agency, DLA Acquisition Locations, Defense Supply Center Columbus BSM, P O Box 3990, Columbus, Ohio, 43216-5000
- ZIP Code
- 43216-5000
- Solicitation Number
- SPM7L5-09-R-0030
- Archive Date
- 3/17/2009
- Point of Contact
- William E Cain,, Phone: 614-692-2686
- E-Mail Address
-
william.e.cain@dla.mil
- Small Business Set-Aside
- Total Small Business
- Description
- CONNECTOR,THROTTLE WIRE EXCEPTIONS TO DWG 7539184: IN LIEU OF QQ-Z-325 FOR ZINC PLATE, USE ASTM B633 CLASS FE/ZN 5, SC1, TYPE II OR III; 1018 STEEL PER ASTM A108 IS AN ACCEPTABLE ALTERNATE MATERIAL. ILO QQ-P-416 USE AMS-QQ-P-416. "FINAL INSPECTION AND ACCEPTANCE OF THE ITEM SHALL BE AT THE ACTUAL MANUFACTURING FACILITY. TECHNICAL INSPECTION IS REQUIRED. THE CONTRACTOR SHALL MAKE DRAWINGS AND TECHNICAL INFORMATION AVAILABLE TO VERIFY THAT THE ITEM MEETS ALL TECHNICAL REQUIREMENTS. COUNT, KIND, AND CONDITION INSPECTIONS ARE NOT ACCEPTABLE. THIS NOTE TAKES PRECEDENCE OVER MASTER SOLICITATION PART ONE PROVISIONS, NOTE 6, QUOTATIONS BY NON-MANUFACTURERS (APR 1984, DCSC 52.217-9C01). FINAL INSPECTION OF PACKAGING, IF REQUIRED, MAY BE CONDUCTED ELSEWHERE." THE INTERNATIONAL ORGANIZATION FOR STANDARDIZATION (ISO) 9002 OR A "TAILORED" PROGRAM MEETING THE FOLLOWING ISO 9002 PARAGRAPHS APPLIES: 4.5, DOCUMENT CONTROL: LIMITED TO INSPECTION AND TESTING AS WELL AS APPLICABLE DRAWINGS, SPECIFICATIONS AND INSTRUCTIONS REQUIRED BY CONTRACT 4.6, PURCHASING: 4.6.1 AND LIMITED TO 4.6.2 A) AND 4.6.4.2, ALL OTHER PARTS OF PARAGRAPH ARE HEREBY DELETED 4.7, CUSTOMER-SUPPLIED PRODUCT: 4.8, PRODUCT IDENTIFICATION & TRACEABILITY: 4.10, INSPECTION & TESTING: 4.11, INSPECTION, MEASURING & TEST EQUIPMENT: 4.12, INSPECTION AND TEST STATUS: 4.13, CONTROL OF NONCONFORMING PRODUCT: 4.14, CORRECTIVE AND PREVENTIVE ACTION: PARAGRAPH 4.14.3 APPLY TO PRODUCT ONLY 4.16, QUALITY RECORDS: FAR CLAUSE 52.246-11 APPLIES "CLASS I OZONE DEPLETING CHEMICALS ARE NOT TO BE USED NOR INCORPORATED IN ANY ITEMS TO BE DELIVERED UNDER THIS CONTRACT. THIS PROHIBITION SUPERSEDES ALL SPECIFICATION REQUIREMENTS BUT DOES NOT ALLEVIATE ANY PRODUCT REQUIREMENTS. SUBSTITUTE CHEMICALS MUST BE SUBMITTED FOR APPROVAL UNLESS THEY ARE AUTHORIZED BY THE SPECIFICATION REQUIREMENTS." DLAD CLAUSE 52.246-9004, PRODUCT VERIFICATION TESTING, IS HEREBY INCORPORATED, AND MAY BE INVOKED AT THE DISCRETION OF THE PROCUREMENT ACTIVITY. IF AQLS ARE LISTED IN THE SPECIFICATION(S) OR DRAWING(S) THEY MAY BE USED TO ESTABLISH THE AUTHORIZED SAMPLE SIZE, HOWEVER, THE ACCEPTANCE NUMBER FOR THIS CONTRACT IS ZERO; I.E., THIS CONTRACT REQUIRES A SAMPLING PLAN THAT ACCEPTS ON ZERO DEFECTS AND REJECTS ON ONE OR MORE DEFECT(S). CRITICAL APPLICATION ITEM I/A/W DRAWING NR 19207 7539184 BASIC AMEND NR C DTD 89 AUG 02 TYPE NUMBER:
- Web Link
-
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=d51d3e87bba4f989e73fe969ddc2ea12&tab=core&_cview=1)
- Record
- SN01732326-W 20090116/090114215829-d51d3e87bba4f989e73fe969ddc2ea12 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |