Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 26, 2008 FBO #2496
DOCUMENT

42 -- Bldg 1332 AFFF Fire Supression - Revised Statement of Work - Floor Plans

Notice Date
9/24/2008
 
Notice Type
Floor Plans
 
NAICS
541990 — All Other Professional, Scientific, and Technical Services
 
Contracting Office
Department of the Air Force, Air Combat Command, 366 CONS, 366 Gunfighter Ave Ste 498, Mountain Home AFB, Idaho, 83648-5258
 
ZIP Code
83648-5258
 
Solicitation Number
F3F3CE8190A003
 
Point of Contact
Donovan A Wall,, Phone: 208-828-6485, Andrzej K Wojcicki, Phone: (208)828-3870
 
E-Mail Address
donovan.wall@mountainhome.af.mil, andrzej.wojcicki@mountainhome.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
Request for Information (i) Request for Information (RFI) (F3F3CE8190A003 Bldg 1332). All interested firms or individuals responding must be registered with the Central Contractor Registration (CCR). (ii) CLIN (0001) Performance of visual and hydrostatic testing of foam tanks, removal/ replacement of foam bladder, including all necessary related work for a complete testing/ maintenance process in order to ensure that the AFFF fire system is reliable in case of use. (iii) ***This requirement is currently UNFUNDED.*** The government does not presently intend to award a contract, but does want to obtain information in the event that funding is obtained. The government may or may not award a contract for some or all of the items in this request. The purpose of this sources sought notice is to identify the availability of qualified sources. The anticipated contract type will be firm fixed price. If your company is able to provide item(s) requested and are interested in this acquisition please submit the following: 1. Point of contact, including a phone number, physical and e-mail address 2. Size status and or SBA certification program of your company. 3. Cage Code for your company. 4. An estimated cost for item(s) requested that includes FOB shipping terms, and an estimated delivery date. ***FYI...366th Contracting Office will most likely be awarding contracts up until midnight on 30 September 08, for Fiscal Year End. Please inform us if your company, or a company representative, will be available to obtain firm quotes on that day.*** (iv) FOB-Destination for delivery to: 366 CES/CECO, Mountain Home AFB, ID 83648. Responsibility and Inspection: Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance of all inspection requirements and Quality Control (QC). must be emailed to Donovan Wall at donovan.wall@mountainhome.af.mil, or faxed to (208) 828-2658. STATEMENT OF WORK QYZH070033 - Repair AFFF Fire Suppression, Fac 1332 24 September 2008 Purpose: Inspect and test aqueous film forming foam (AFFF) system within Facility 1332 in accordance with UFC 3-600-02, Table 2.9. 1. Inspect and verify that all eleven Control Valves (unsupervised and unmonitored) function properly by operating valves through their entire travel distance and that they are returned to their proper (open) position. 2. Inspect the proportioning system for proper valve alignment and system condition. 3. Inspect and ensure blow down valve is closed. Clean and lubricate the stem. 4. Verify operability of manual actuators. 5. Inspect piping hangers, heads for obstuciton, piping for leaks, riser condition, and nozzles for condition and location. 6. Flush balancing valve to prevent concentrate build-up on diaphragm. Inspect the water supply strainer (1) and clean if necessary. 7. Ensure that panels are secured and indicator lamps functional, notification appliances are in place, manual stations (about 12) in place and unobstructed, and that sprinkler spares are available and undamaged. Control Panels consist of the following: • Monaco BT2-8 FSK Transceiver • Notifier AFP-200 - (AFFF Control Panel) • Notifier RP-1001 - (AFFF FACP OMN, Zones 1 & 2) • Notifier RP-1001 - (AFFF FACP OMN, Zones 3 & 4) • Notifier RP-1001 - (AFFF FACP OMN, Zones 5) • Notifier RP-1001 - (Preaction, Zone 6) • Notifier RP-1001 - (Preaction, Zone 7) 8. Drain AFFF from foam concentrate tank, flush foam tank. Remove foam tank bladder and perform internal inspection of tank for corrosion and cracks. Perform hydrostatic test on tank. Replace foam tank bladder with new bladder. (Tank is Part # CCS3-2000HA, manufactured by Arrow Tank and Engineering Company.) 9. Refill foam concentrate tank with 3% AFFF solution that meets MIL-F-0024385E(SH). (2000 gallon tank) 10. Conduct full AFFF flow test to ensure proper system function and AFFF solution mixing. Verify nozzle (head) coverage during the flow test. Adjust nozzle head position if coverage requirements are not met. Take test sample of discharged AFFF solution and have it tested to verify solution is not less than 3% AFFF. Refill foam concentrate tank with 3% AFFF solution to replace amount lost during test. The length of foam test critical in determining amount of foam necessary for replacement. Coordiante flow test time and duration with Fire Department (366 CES/CEF), Civil Engineering (366 CES/CEPM), Environmental Engineering (366 CES/CEAN), and Facility 1333 Building Manager a. Hangar 1332 has 21,768-ft² of AFFF coverage. The system sprays from ground mounted oscillating foam cannons in a pattern along the floor and has not been properly configured for F-15 aircraft. The foam system is believed to be still set up per drawings for underwing foam coverage of B-52's and needs adjustment to new aircraft usage. (see attached floor plan layout of F-15 aircraft) b. The building roof is at an angled slope and the height varies from 22-ft up to 48-ft. c. Hangar has trench drains in the center of the floor to capture the foam and pump it to a containment pond. d. There are test headers inside the hangar. e. It is suggested to prepare for the foam test and clean up by covering the support pillars, walls, and electrical boxes with plastic wrap to prevent water damage then use push brooms or squeegees and push the foam and water solution towards the drains. The foam can also be washed down using a regular garden hose and hand held nozzle. 11. Clean up area of hangar affected by AFFF discharge test. 12. Provide a list of all inspections, test results and corrective actions to Contracting Officer. END
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=40e71bbff3064ea838eece39b615dad2&tab=core&_cview=1)
 
Document(s)
Floor Plans
 
File Name: Revised Statement of Work for Fire Suppression System in Hangar 1332 (QYZH070033 - Repair AFFF Fire Suppression, Fac 1332 - SOW (24 Sep 08).doc.doc)
Link: https://www.fbo.gov//utils/view?id=94e9e8579e4130cc219e791e5b9bceb5
Bytes: 48.50 Kb
 
File Name: F-15 Floor Layout (F-15 floor layout.pdf)
Link: https://www.fbo.gov//utils/view?id=1a5b1bf2cc9271adf4a8f3e9ad5ebb3e
Bytes: 168.64 Kb
 
File Name: Piping and Wiring Diagram (MHAFB-DV-06071.tif)
Link: https://www.fbo.gov//utils/view?id=a875e5f712a3bbc886efd2b091327f0f
Bytes: 5,847.43 Kb
 
File Name: Piping Diagram - East Wing (MHAFB-DV-06072.tif)
Link: https://www.fbo.gov//utils/view?id=a87c6930676f13060341a181c3ccc60f
Bytes: 6,977.50 Kb
 
File Name: Piping Diagram - West Wing (MHAFB-DV-06073.tif)
Link: https://www.fbo.gov//utils/view?id=372178e94f39df77b2d677af09174d2c
Bytes: 6,748.61 Kb
 
File Name: Piping Diagram - Center Section (MHAFB-DV-06074.tif)
Link: https://www.fbo.gov//utils/view?id=1a5cc6e3f5156f42f8361db4690fca2b
Bytes: 7,243.85 Kb
 
File Name: Under Wing Nozzles - B-52 (MHAFB-DV-06075.tif)
Link: https://www.fbo.gov//utils/view?id=20bf2c616e5ee08965d04c927f054c21
Bytes: 6,802.24 Kb
 
File Name: Details (MHAFB-DV-06076.tif)
Link: https://www.fbo.gov//utils/view?id=ce899f3f8e9882b8c93364b896f0073d
Bytes: 5,304.86 Kb
 
File Name: Fire Protection Equipment Room (MHAFB-DV-06086.tif)
Link: https://www.fbo.gov//utils/view?id=4f138a599072d536b9c4113687ad41e5
Bytes: 4,876.89 Kb
 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Mountain Home AFB, Mountain Home, Idaho, 83648, United States
Zip Code: 83648
 
Record
SN01680250-W 20080926/080924222300-40e71bbff3064ea838eece39b615dad2 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.