Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 21, 2008 FBO #2491
SOLICITATION NOTICE

71 -- Office Furniture

Notice Date
9/19/2008
 
Notice Type
Modification/Amendment
 
Contracting Office
Department of the Army, Army Contracting Agency, North Region, ACA, Fort Lewis, Bldg 2015 Box 339500, Ft Lewis, WA 98433
 
ZIP Code
98433
 
Solicitation Number
W68MX382315255
 
Response Due
9/27/2008
 
Archive Date
3/26/2009
 
Point of Contact
Name: Client Services, Title: Sourcing Agent, Phone: 1.877.9FEDBID, Fax: 703.442.7822
 
E-Mail Address
clientservices@fedbid.com;
 
Small Business Set-Aside
Total Small Business
 
Description
MODIFICATION NOTICE: Bids are being solicited under solicitation number W68MX382315255. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation is issued as an invitation for bids (IFB), unless otherwise indicated herein. If your company can provide the product/services listed on the solicitation and comply with all of the solicitation instructions, please respond to this notice. To view the specifications, please go to www.FedBid.com and reference Buy No. 93486_01. GSA Schedule Bids Only: Sellers bidding on this opportunity MUST have the items requested on an existing GSA Schedule. The Schedule must either be in the Seller's name or the Seller must be able to document its ability to act as an agent of a partner's Schedule. Sellers may offer Open Market items only in accordance with the approved Terms and Conditions of their respective GSA Schedule AND upon approval from the soliciting Contracting Officer. Information regarding GSA Schedules can be found at www.GSA.gov. This requirement is a [ Small Business ] set-aside and only qualified sellers may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2008-09-27 12:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be Tacoma, WA 98431 The USA ACA Fort Lewis requires the following items, Meet or Exceed, to the following: LI 001, G-57-2 DESCRIPTIONFree Standing Horseshoe shape work area with Peninsula : 8'6" x 13'6" x 8'Modular DesksQty148 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" footQty136 X 30 X 29Left and right upright should be transitional 24" footQty130 X 30 X 29Left and right upright should be transitional 24" footQty154 X 30 X 29Left upright should be transitional with a 24" foot /Right upright should be a full upright with a 30" footQty248 X 48 X 30 X 30 Curved Corner/ Left and right upright should be transitional 24" footQty148 X 24 Free standing peninsulaCHARACTERISTICS:Worksurface shall consist of complete steel base unit and high pressure laminate top.Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel).Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge.Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate.Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units.A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components.Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routing through abutting worksurfaces. Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel.Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires.Wire retention device must permit separation of data/voice transmissions from utility power cables.Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA; LI 002, G-57-2 DESCRIPTION:OrganizersQty136H X 48W OrganizerClosed Compartment, 36"H with shelf on top with 20" clearance Qty136H X 36WOrganizer with shelf, 20" clearanceQty136H X 30WOrganizer with shelf, 20" clearanceQty136H X 54WClosed Compartment, 36"H with shelf on top with 20" clearance Qty236H X48X48 Corner Organizer with curved shelf, 20" clearanceCHARACTERISTICSOverheads shall be self-supporting (not panel-hung) and capable of being readily relocatedThe overhead support structure shall be mechanically attached to the worksurface with no exposed worksurface.Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with.82" front radius.Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thicknessThe finish of the overhead system shall match the finish of all other workstation components.Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders.Flipper doors shall be operational from a seated positionFlipper doors and shelf units shall be of metal construction with radiused edges.Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws.Privacy panel shall be provided as required in height of 20".Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA; LI 003, G-57-2 DESCRIPTIONTask LightingCHARACTERISTICS24" Task Light For 30" +Task lights shall be standard components of the manufacturer's modular furniture products.Task lights shall have a finish to match other workstation componentsTask lights shall have a structurally sound mounting device which will prevent accidental removal butwhich can be easily removed and relocated,All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design.Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 4, EA; LI 004, G-57-2 DESCRIPTIONMobile PedestalsCHARACTERISTICS Box/Box/File Mobile PedestalPedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3-1989All file drawers shall have full extension ball-bearing suspensions or slides.All drawers shall operate smoothly but shall not open accidentally.Drawer front shall include a full width pull handle.Pedestal body shall of metal construction with seamless shell.Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools.Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must befurnished with internal counterbalance weights to prevent instability and tipping.Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 2, EA; LI 005, G-57-2 DESCRIPTIONPower 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS -Circuit breaker for overload protectionMounting Hardware15' power cord-420 Joule rating400 V clamping-40db ratingLess than 5 nano sec. response timeCircuit breaker for overload protection, 2, EA; LI 006, G-57-2-01 DESCRIPTIONFree Standing Horseshoe shape work area with Peninsula:8'6" x 13'6" x 8'Modular Desks:Qty248 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" footQty142 X 30 X 29Left and right upright should be transitional 24" footQty248 X 48 X 30 X 30 Curved Corner/ Left and right upright should be transitional 24" footCHARACTERISTICSWorksurface shall consist of complete steel base unit and high pressure laminate top.Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel).Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge.Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate.Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units.A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components.Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routing through abutting worksurfaces,.Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel.Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires.Wire retention device must permit separation of data/voice transmissions from utility power cables.Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wires from falling out of raceway area., 1, EA; LI 007, G-57-2-01 DESCRIPTIONOrganizersQty236H X 48W OrganizerClosed Compartment, 36"H with shelf on top with 20" clearance Qty136H X 42WOrganizer with shelf, 20" clearanceQty236H X48X48 Corner Organizer with curved shelf, 20" clearanceCHARACTERISTICSOverheads shall be self-supporting (not panel-hung) and capable of being readily relocatedThe overhead support structure shall be mechanically attached to the worksurface with no exposedworksurface.Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with.82" front radius.Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thicknessThe finish of the overhead system shall match the finish of all other workstation components.Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders.Flipper doors shall be operational from a seated positionFlipper doors and shelf units shall be of metal construction with radiused edges.Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws.Privacy panel shall be provided as required in height of 20".Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA; LI 008, G-57-2-01 DESCRIPTIONTask Lighting24" Task Light For 30" +CHARACTERISTICSTask lights shall be standard components of the manufacturer's modular furniture products.Task lights shall have a finish to match other workstation componentsTask lights shall have a structurally sound mounting device which will prevent accidental removal butwhich can be easily removed and relocated,All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design.Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 3, EA; LI 009, G-57-2-01 DESCRIPTIONMobile PedestalsCHARACTERISTICSBox/Box/File Mobile PedestalPedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3-All file drawers shall have full extension ball-bearing suspensions or slides.All drawers shall operate smoothly but shall not open accidentally.Drawer front shall include a full width pull handle.Pedestal body shall of metal construction with seamless shell.Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools.Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must befurnished with internal counterbalance weights to prevent instability and tipping.Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 2, EA; LI 010, G-57-2-01 DESCRIPTION Power 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS-Circuit breaker for overload protectionMounting Hardware15' power cord-420 Joule rating400 V clamping-40db ratingLess than 5 nano sec. response timeCircuit breaker for overload protection, 2, EA; LI 011, G-57-ADESCRIPTIONFree Standing Work area Modular DesksQty172 X 30 X 29 Left upright should be a full upright with a 30" foot/Right upright should be transitional with a 24" foot including full modesty panel142 X 30 X 29Left upright should be transitional 24" foot /Right 19" footWorksurface shall consist of complete steel base unit and high pressure laminate top.Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel).Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge.Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate.Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units.A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components.Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routingthrough abutting worksurfaces,.Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel.Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalent non-conductive material to organize and retain cable and wires.Wire retention device must permit separation of data/voice transmissions from utility power cables.Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA; LI 012, G-57-ADESCRIPTION OrganizersCHARACTERISTICS36H X 42WOrganizer closed compartment and upper shelf 20" clearanceOverheads shall be self-supporting (not panel-hung) and capable of being readily relocatedThe overhead support structure shall be mechanically attached to the worksurface with no exposedworksurface.Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with.82" front radius.Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thicknessThe finish of the overhead system shall match the finish of all other workstation components.Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders.Flipper doors shall be operational from a seated positionFlipper doors and shelf units shall be of metal construction with radiused edges.Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws.Privacy panel shall be provided as required in height of 20".Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA; LI 013, G-57-A DESCRIPTION Task LightingCHARACTERISTICS24" Task Light For 30" +Task lights shall be standard components of the manufacturer's modular furniture products.Task lights shall have a finish to match other workstation componentsTask lights shall have a structurally sound mounting device which will prevent accidental removal butwhich can be easily removed and relocated,All fixture diffusers, grilles, or other covering shall be easily removable to permit cleaning and replacing. Includes T8 lamp (1" diameter). Fixture diffuser shall be of prismatic design.Each fixture shall include a nine foot factory installed electrical cord set with a grounded plug. Cord set must match finish of fixture., 1, EA; LI 014, G-57-A DESCRIPTION Mobile PedestalsCHARACTERISTICSBox/Box/File Mobile PedestalPedestals shall be available mobile Pedestals shall be tested in accordance with the requirements of ANSI/BIFMA X5.3-1989All file drawers shall have full extension ball-bearing suspensions or slides.All drawers shall operate smoothly but shall not open accidentally.Drawer front shall include a full width pull handle.Pedestal body shall of metal construction with seamless shell.Mobile pedestal shall include two (2) locking and two (2) non-locking casters that can be easily installed without tools.Drawers shall be of metal construction with a textured or smooth finish. Mobile pedestals must befurnished with internal counterbalance weights to prevent instability and tipping.Box drawer requirements include one (1) pencil or convenience tray and minimum of two (2) dividers. All file drawers shall come with hardware to accommodate legal or letter size hanging file folders., 1, EA; LI 015, G-57-A DESCRIPTION Power 15 Amp Under-Surface Mounted Power Strip W/ Surge ProtectorCHARACTERISTICS-Circuit breaker for overload protectionMounting Hardware15' power cord-420 Joule rating400 V clamping-40db ratingLess than 5 nano sec. response timeCircuit breaker for overload protection, 1, EA; LI 016, J-57-7 DESCRIPTION Free Standing Work area --- Modular DesksQty436 X 24 X 29 Left upright should be a full upright with a 24" foot/Right upright should be transitional with a 19" foot including full modesty panelQty230 X 24 X 29Left and right upright 19"footQty336 X 36 X 24 X 24 Curved Corner, Left upright should be transitional 19" foot /Right 19" footCHARACTERISTICSWorksurface shall consist of complete steel base unit and high pressure laminate top.Worksurface shall be available as a self-supporting unit (freestanding) which includes two (2) uprights (legs) with tubular feet and a 12", 26 or 32 modesty panel (back panel).Uprights shall be constructed of 16 and 20 gauge steel with fully radiused leading edge.Modesty panel shall be constructed of 20 gauge steel and includes cable access ports which correspond to cable access ports located in the desktop laminate.Partial modesty panel shall be available to provide minimum clearance of 16" (applicable to 29" high worksurface) to allow for ventilation, base plate or raceway accommodation. Corner Worksurfaces and transition connectors shall be available as freestanding units.A full depth leg design and full height modesty panel design shall be available to address privacy and aesthetic requirements and shall be available as specified options. Options must maintain same construction specifications as standard components.Standard modesty panel and full height modesty panel shall include fully welded integrated horizontal raceway to manage power cord sets, cables, voice and data lines and must permit continuous cable routingthrough abutting worksurfaces,.Fully welded steel horizontal raceway shall provide a cable management area 6"h x 1.7" deep and run the entire perimeter of worksurface modesty panel.Worksurface shall include Power Rings- wire retention devices constructed of nylon or equivalentnon-conductive material to organize and retain cable and wires.Wire retention device must permit separation of data/voice transmissions from utility power cables.Modesty panel or raceway must accept multiple wire retention devices to prevent cables and wiresfrom falling out of raceway area., 1, EA; LI 017, J-57-7 DESCRIPTION OrganizersQty116H X 72WOrganizer with Reception surfaceQty136H X 36WOrganizer closed compartment and upper shelf 20" clearanceQty136H X 72WOrganizer closed compartment and upper shelf 20" clearanceCHARACTERISTICSOverheads shall be self-supporting (not panel-hung) and capable of being readily relocatedThe overhead support structure shall be mechanically attached to the worksurface with no exposed worksurface.Overhead units shall consist of two (2) vertical uprights and modular rear panel's) to create aself-supporting structure for privacy and workstation storage. Uprights shall be of 16 and 20 gauge steel construction with.82" front radius.Overhead design shall permit use with other manufacturer's laminate tops (1" minimum top thicknessThe finish of the overhead system shall match the finish of all other workstation components.Overhead compartments shelf depth shall be at least 13.5" deep to accommodate 3-ring binders.Flipper doors shall be operational from a seated positionFlipper doors and shelf units shall be of metal construction with radiused edges.Privacy panel shall be constructed of steel and include a fabric covered, tackable surface consisting ofa single piece of fabric and attached securely and continuously along the entire perimeter of the panel with no visible puckering or flaws.Privacy panel shall be provided as required in height of 20".Flipper door shall be available with textured steel front or fabric covered with a variety of fabric choices., 1, EA; LI 018, J-57-7 DESCRIPTIONTask LightingQty124" Task Light Qty148" Task Light CHARACTERISTICSTask lights shall be standard components of the manufacturer's modular furniture -- Please refer to FedBid for complete list of contract requirement(s) and terms and conditions.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=59b0ade808c34339f8906b8f60c5ee5c&tab=core&_cview=1)
 
Place of Performance
Address: Tacoma, WA 98431<br />
Zip Code: 98431<br />
 
Record
SN01676235-W 20080921/080919221033-59b0ade808c34339f8906b8f60c5ee5c (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.