FBO DAILY ISSUE OF SEPTEMBER 14, 2008 FBO #2484
SOLICITATION NOTICE

Z -- Sandy Hook, NJ - Glycol System Conversion

Notice Date
9/12/2008
 
Notice Type
Presolicitation
 
Contracting Office
Department of the Interior, National Park Service, NPS - All Offices, NER - GATE Gateway National Recreation Area 210 New York Avenue Staten Island NY 10305
 
ZIP Code
10305
 
Solicitation Number
Q1775080117
 
Response Due
9/22/2008
 
Archive Date
9/12/2009
 
Point of Contact
Marvin Newman Contracting Officer 7183544610 Marvin_Newman@nps.gov;<br />
 
Small Business Set-Aside
Very Small Business
 
Description
The solicitation will be available at http://ideasec.nbc.gov on or about September 12, 2008. PAPER COPIES OF THIS SOLICITATION WILL NOT BE ISSUED AND TELEPHONE REQUESTS OR FAX REQUESTS FOR THIS SOLICITATION WILL NOT BE ACCEPTED. Solicitation Number Q1775080117. Description: The National Park Service is seeking a qualified contractor for the conversion of the existing wet sprinkler system to a "glycol" system Project Scope General purpose: The project consists of the conversion of the existing wet and dry sprinkler system in existing building 102 at Sandy Hook Gateway National Recreation Area, Monmouth County New Jersey. Specific purpose: To convert the existing wet and dry fire suppression system to a freeze resistant automatic fire sprinkler system in building 102 where the heating system will be disabled for the winter. Required Services: The services to be provided will be the investigation of the existing building and install the most appropriate system which includes but is not limited to the conversion of the existing system to a glycol based system, the removal of the valve and pressure switch from the dry portion ( in the attic) and replace with a pipe and flow switch. The installation of an anti freeze loop in the water control room with a new main flow switch. Bleed the system of air, install signage at appropriate location as per NFPA guidelines. Activate the system. The system shall meet the requirements of NFPA and any other codes having jurisdiction. Warranty Contractor shall warranty system from failure to a minus 20 degrees F, for a period of 1 year. Extended warranty The contractor shall provide a price quote to extend the warranty for a period of 3 years past initial warranty. Period of performance The successful bidder shall have 60 days from notice to proceed to complete the installation and testing. Submission requirements Those responding to this announcement shall fully address their capabilities, capacity and qualifications, indicating similar projects completed. LOCATION: The work will occur at the Building 102, at the Sandy Hook Unit of Gateway National Recreation Area, Sandy Hook, NJ.. The NAICS code for this project is 238220 and the small business size standard is $14.0 million. This contract is set-aside for Emerging Small Business which is equaled to 50% of the small business size. Contract duration is 60 days following notice to proceed. In accordance with FAR Subpart 36.204, the price range for this contract is between $10,000 and $25,000. The National Park Service encourages the participation of disadvantaged and women-owned business enterprises. A site visit can be arranged by contacting Brian Forseth at (732) 872-5921. Responses are due by 5:00 PM on September 22, 2008. Search by referencing the solicitation number (above), Department of the Interior, National Park Service. Individual requests for solicitation packages will NOT be accepted. The point of contact for this solicitation is Marvin Newman, Contracting Officer, National Park Service, 210 New York Ave, Staten Island, NY 10305. Email address is Marvin_Newman@nps.gov and the voice telephone is (718) 354-4610. In order to download a copy of the solicitation, vendors will be asked to register their company with the electronic commerce website. Be prepared with your company's DUNS number, available from Dun and Bradstreet at 1-888-546-0024, and your Federal Tax Identification Number (TIN). All vendors should pre-register to save time, by logging onto the Central Contractor Registry (CCR) at the Internet site at http://www.ccr.gov and by registering Representations, Certifications and Other Statements of Offerors at http://www.orca.bpn.gov. Available files to download will be in one, or a combination, of the following formats: HTML, Microsoft Word, Microsoft Excel, Portable Document Format (PDF), or TIF. Responses from Bidders will be accepted at the address listed in Block 5a of the solicitation in hard copy with the manual signature of the authorized company official. Facsimile offers shall NOT be accepted. The Government reserves the right to cancel this solicitation. The announcement does not constitute the solicitation. End of Announcement.
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=2d1d9724e38ed62d83b86fccc0788137&tab=core&_cview=1)
 
Place of Performance
Address: Gateway National Recreation Area, Sandy Hook, NJ<br />
Zip Code: 07732<br />
 
Record
SN01669537-W 20080914/080912223703-40ae51935310e92260066d6b4db3e5bc (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.