Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 14, 2008 FBO #2484
SOLICITATION NOTICE

54 -- Mout Sites

Notice Date
9/12/2008
 
Notice Type
Modification/Amendment
 
Contracting Office
Department of the Army, Army Contracting Agency, South Region, ACA, Fort Hood, Bldg 1001, 761st Tank Bn Ave, Rm w113, Fort Hood, TX 76544
 
ZIP Code
76544
 
Solicitation Number
W90TKY82340016
 
Response Due
9/16/2008
 
Archive Date
3/15/2009
 
Point of Contact
Name: Leeann Burke, Title: Contracting Officer, Phone: 2542872434, Fax: 2542875506
 
E-Mail Address
leeann.burke@us.army.mil;
 
Small Business Set-Aside
Total Small Business
 
Description
AMENDMENT NOTICE: This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR 13.5, as applicable, and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation number is W90TKY82340016 and is issued as an invitation for bids (IFB), unless otherwise indicated herein. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular FAC 2005-26. The associated North American Industrial Classification System (NAICS) code for this procurement is 332311 with a small business size standard of 500 employees. This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2008-09-16 15:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be Multiple shipping information. The USA ACA Fort Hood requires the following items, Meet or Exceed, to the following: LI 001, - 2 STORY MOSQUE, Non-Live Fire Urban Training Unit Specifications: Base: 40L X 16W. 2 story. Four containerized units; two containers with reinforced roof on base level and two standard containers on second level. One 12 dome on roof to replicate Mosque. One standard door (36x80) and 4 windows (36x36). Ten reconfigurable interior walls (4x8) and four reconfigurable interior walls (8x8). Unit will contain one interior stairway and railing., 3, EA; LI 002, SINGLE, Non-Live Fire Urban Training Specifications: Base: 40L X 8W. 1 story. Unit will contain one container with reinforced roof. One standard door (36x80) and 4 windows (36x36). Four reconfigurable interior walls (4x8). Unit will contain one interior stairway and railing. Metal guard rail will surround the roof on the second story creating a balcony. Reconfigurable, mobile, modular training unit for non live fire urban training., 7, EA; LI 003, SINGLE UNIT Non-Live Fire Urban Training Unit Specifications: Base: 40L X 8W, 1 story. One standard door (36x80) and 4 windows (36x36). Four reconfigurable interior walls (4x8)., 77, EA; LI 004, SINGLE UNIT, Non-Live Fire Urban Training Unit Specifications: Base: 20L X 8W. 1 story. One standard door (36x80) and 2 windows (36x36). One reconfigurable interior wall (4x8)., 52, EA; LI 005, SINGLE UNIT, Non-Live Fire Urban Training UnitSpecifications: Base: 10L X 8W. 1 story. One standard door (36x80) and 2 windows (36x36)., 28, EA; LI 006, TWO STORY, Non-Live Fire Urban Training Unit Specifications: Base: 40L X 16W. Unit will contain three containers; base will be two containers wide (to include reinforced roof) and one standard container as a second story. Two standard doors (36x80) and 10 windows (36x36). Five reconfigurable interior walls (4x8). Metal guard rail will surround the remaining roof on the second story creating a balcony. Unit will contain one interior stairway and railing., 14, EA; LI 007, TWO-STORY, Non-Live Fire Urban Training Unit Specifications: Base: 120L X 8W. Unit will contain four containers; two containers with reinforced roof as base, placed side by side, and two containers as a second story. One standard door (36x80) and 8 windows (36x36). Eight reconfigurable interior walls (4x8). Unit will contain one interior stairway and railing., 1, EA; LI 008, RESIDENTIAL HOUSING HUT, Non-Live Fire Urban Training Unit Specifications: Base: 10L X 12W. One standard door (36x80) and 2 windows (36x36). Unit will contain an awning off of the front of the building to create a porch area., 30, EA; LI 009, TWO-STORY GUARD TOWER, Non-Live Fire Urban Training Unit Specifications: Base: 10L X 8W. Unit will contain two containers, creating a second story. One standard door (36x80) and 2 windows (36x36) in the base unit. Upper unit will be configured to represent a guard tower with maximum sized windows on each wall., 14, EA; LI 010, ONE-STORY MKTPLACE, Non-Live Fire Urban Training Unit Specifications: Base: 40L X 8W. Unit will be separated into 5 equal sized vendor stalls. Five roll-up doors (6Wx6H) and four reconfigurable interior walls (8x8)., 2, EA; LI 011, ONE-STORY MKTPLACE, Non-Live Fire Urban Training Unit Specifications: Base: 56L X 48W. Unit will consist of three containers, in a U-shaped configuration. Each container will be separated into 4 equal sized vendor stalls. Fifteen roll-up doors (6Wx6H) and twelve reconfigurable interior walls (8x8). Unit Reconfigurable, mobile, modular training site designed for non live fire urban training., 2, EA; LI 012, C SHAPED, SINGLE STORY, Non-Live Fire Urban Training Unit Specifications: Base: 96L X 48W. Unit will consist of 6 containers, in a C-shaped configuration to create a courtyard. The entire complete unit will consist of three standard doors (36x80), 22 windows (36x36) and twelve reconfigurable interior walls (4x8)., 2, EA; LI 013, ONE STORY, L SHAPED, Non-Live Fire Urban Training Unit Specifications: Base: 48L X 40W. Unit will consist of two containers placed in an L-shaped configuration. Each unit will contain one standard door (36x80), 4 windows (36x36) and two reconfigurable interior wall (4x8)., 5, EA; LI 014, MOLDED CONCRETE COURTYARD WALLS, NLF Urban Training Unit Specifications: Base: 5W. Courtyard Walls in sections of 8'Hx5'W, made of concrete., 252, EA; For this solicitation, USA ACA Fort Hood intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. USA ACA Fort Hood is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids. All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com. Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process. Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com. Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. In addition to providing pricing at www.FedBid.com for this solicitation, each Offeror must provide any required, NON-PRICING responses directly to clientservices@fedbid.com. Delivery will be at different sites in the training areas to be determined at time of award. CCR Requirement - Company must be registered on Central Contractor Registration (CCR) before an award could be made to them. If company is not registered in CCR, they may do so by going to CCR web site at http://www.ccr.gov. See attached applicable provisions and clauses. Response from vendors is required, if applicable, to the following: 52.209-5, 52.209-6, 52.212-3, 52.212-3 Alt1, 52.222-48 and 252.247-7022. Any applicable provisions and clauses must be provided electronically prior to the solicitation closing time and date by email to clientservices@fedbid.com. Proposed responders must submit any questions concerning this solicitation before 11 Sep 08, 1300 CST, to reasonably expect a response from the Government. Those questions not received within the prescribed date will not be considered. Contact ClientServices@FedBid.com or call 1-877-9FEDBID to address any questions or comments Bid MUST be good for 30 days after submission. FOB Destination CONUS (CONtinental U.S.)
 
Web Link
FedBizOpps Complete View
(https://www.fbo.gov/?s=opportunity&mode=form&id=0c8c8774b193fdb4907eef4280dabd26&tab=core&_cview=1)
 
Place of Performance
Address: Multiple shipping information.<br />
Zip Code: Multiple<br />
 
Record
SN01668850-W 20080914/080912222004-0c8c8774b193fdb4907eef4280dabd26 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.