Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 01, 2008 FBO #2287
SOLICITATION NOTICE

Y -- UPGRADE HVAC

Notice Date
2/28/2008
 
Notice Type
Solicitation Notice
 
NAICS
491110 — Postal Service
 
Contracting Office
United States Postal Service, Facilities Purchasing, Eastern Facilities Service Office, PO Box 27497, Greensboro, NC, 27498-1103, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
362575-08-A-0022
 
Response Due
4/25/2008
 
Archive Date
6/10/2008
 
Point of Contact
Cindy Shepherd, Facilities Contract Specialist, Phone 336/605-3536
 
E-Mail Address
cindy.g.shepherd@usps.gov
 
Description
The Postal Service plans to issue a Fixed Price Contract to replace / upgrade the existing HVAC system serving the approximately 160,000 square foot Main Post Office at Mansfield, Ohio in accordance with USPS approved specifications and drawings. Base bid work includes replacing existing hot water pumps, expansion tanks, air separators, make-up water valves, and modify branch piping as noted. Replacing chilled water pump motors and convert existing chilled water system to variable speed system. Replacing Air Handlers AHU1-10, modifying distribution and balance. Installing new terminal units in office areas. Providing new diffusers as noted on drawings. Installing a new direct digital control backbone and front end. Providing energy metering for main domestic water, natural gas service and electric utilities. Patching finishing work, ceiling work as required and replace all ceiling tile and grid damaged during construction. Providing a York Microgateway to allow communication to the two (2) existing chillers. Provide BACnet DDC control system per design documents. BASC shall be responsible for interconnecting wiring, programming, etc. Fill, flush, test piping system; balance entire chilled water and heating hot water systems; balance all air distribution system. Reconfiguration of existing unit substation and motor control center, as required, allowing for connection of new loads. Demolition of existing motor control centers. Furnish and install new power distribution centers. Revisions to the existing fire alarm system, replacement of existing air handling unit duct detectors. Provide a carbon monoxide and nitrous oxide detection system to initiate the existing exhaust fan ventilation for the VMF. New AHUs to be rigged into the building through openings in roof. All roof cutting and patching are to be performed under a separate roofing contract. Contractor to coordinate with roofing contractor, for exact size and location of openings in roof. Openings are figured to be in-between joists with no cutting of joists allowed. Contractor to be responsible for disassembling existing units to remove and to bring new units into the building.
 
Place of Performance
Address: 200 N. Diamond Street, Mansfield, Ohio
Zip Code: 44901-9997
Country: UNITED STATES
 
Record
SN01520062-W 20080301/080228225415 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.