Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 24, 2008 FBO #2281
MODIFICATION

54 -- HAZARDOUS MATERIAL STORAGE BUILDINGS

Notice Date
2/22/2008
 
Notice Type
Modification
 
Contracting Office
976 William H. Wilson Ave., Ste 100, Bldg. 621, Fort Stewart, GA 31314
 
ZIP Code
31314
 
Solicitation Number
W81BYT73330602
 
Response Due
2/22/2008
 
Archive Date
8/20/2008
 
Point of Contact
Name: Monteene Wampler, Title: Purchasing Agent/Contract Specialist, Phone: 9127675278, Fax: 9127678437
 
E-Mail Address
monteene.wampler@stewart.army.mil;
 
Small Business Set-Aside
Total Small Business
 
Description
MODIFICATION NOTICE: Bids are being solicited under solicitation number W81BYT73330602. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued. The solicitation is issued as an invitation for bids (IFB), unless otherwise indicated herein. If your company can provide the product/services listed on the solicitation and comply with all of the solicitation instructions, please respond to this notice. To view the specifications, please go to www.FedBid.com and reference Buy No. 61991. GSA Schedule Bids Preferred, But Not Required: Sellers may either provide a GSA Schedule or an Open Market bid. If bidding with a GSA Schedule, the requested items must be on that Schedule. The Schedule must either be in the Seller's name or the Seller must be able to document its ability to act as an agent of a partner's Schedule. Sellers may offer Open Market items only in accordance with the approved Terms and Conditions of their respective GSA Schedule AND upon approval from the soliciting Contracting Officer. Information regarding GSA Schedules can be found at www.GSA.gov. This requirement is a [ Small Business ] set-aside and only qualified sellers may submit bids. The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2008-02-22 14:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com. FOB Destination shall be HUNTER ARMY AIRFIELD, GA 31409 The USA ACA Ft. Stewart requires the following items, Brand Name or Equal, to the following: LI 001, MOTORPOOL #1 BUILDING: HAZARDOUS MATERIAL STORAGE BUILDING, FOUR HOUR FIRE RATED, SIZE: 7'6" X 6'6" X 9'0" HIGH, STANDARD EQUIPMENT. TWO PART CHEMICAL RESISTANT EPOXY PAINT INTERIOR AND EXTERIOR. POLYURETHANE TOP COAT ON EXTERIOR. SIX AIR CHANGES PER HOUR NATURAL VENTILATION. EXTERIOR GROUND CONNECTION. CORRISION RESISTANT EPOXY COATED STEEL GRATE FLOORING, FORKLIFT POCKETS, DOOR EQUIPPED WITH UL LISTED SELF-CLOSING DEVICE, KEYED LOCK AND INTERIOR SAFETY RELEASE. ALL VENTS EQUIPPED WITH UL LISTED 3 HOUR FUSIBLE LINK DAMPERS. SEISMIC TIE DOWN PADS, ONE SET OF 6'0"W X 6'8"H DOUBLE DOORS, 3 HOUR FIRE RATED TO INCLUDE INSULATION IN WALLS (R11). SELF CONTAINED EYEWASH STATION, ADJUSTABLE SHELVING 16"D X 2"LIP 4 ROWS ALL WALLS (SHELVING). EXPLOSION VENTING SKYLIGHT PANELS (EVP-SKY), DRY CHEMICAL FIRE SUPPRESSION SYSTEM WITH ALARM BELL (DC), 1, EA; LI 002, MOTORPOOL #1 BUILDING: INSULATION IN WALLS AND CEILING, ITEM #R11, 42, EA; LI 003, MOTORPOOL #1 BUILDING: SELF CONTAINED EYE WASH, ITEM NO: EW-SC, 1, EA; LI 004, MOTORPOOL #1 BUILDING: ADJUSTABLE SHELVING: SIZE: 16"D X 2"LIP, 4 ROWS ALL WALLS., 60, EA; LI 005, MOTORPOOL #1 BUILDING: EXPLOSION VENTING PANELS, ITEM #EVP-SKY, 1, EA; LI 006, MOTORPOOL #1 BUILDING: DRY CHEMICAL FIRE SUPPRESSION SYSTEM WITH ALARM BELL, ITEM #DC, 1, EA; LI 007, MOTORPOOL #2 BUILDING: HAZARDOUS MATERIAL STORAGE BUILDING, FOUR HOUR FIRE RATED, SIZE: 7'6" X 6'6" X 9'0" HIGH, STANDARD EQUIPMENT. TWO PART CHEMICAL RESISTANT EPOXY PAINT INTERIOR AND EXTERIOR. POLYURETHANE TOP COAT ON EXTERIOR. SIX AIR CHANGES PER HOUR NATURAL VENTILATION. EXTERIOR GROUND CONNECTION. CORRISION RESISTANT EPOXY COATED STEEL GRATE FLOORING, FORKLIFT POCKETS, DOOR EQUIPPED WITH UL LISTED SELF-CLOSING DEVICE, KEYED LOCK AND INTERIOR SAFETY RELEASE. ALL VENTS EQUIPPED WITH UL LISTED 3 HOUR FUSIBLE LINK DAMPERS. SEISMIC TIE DOWN PADS, ONE SET OF 6'0"W X 6'8"H DOUBLE DOORS, 3 HOUR FIRE RATED. MODEL NO: LFR48, 1, EA; LI 008, MOTORPOOL #2 BUILDING: INSULATION IN WALLS AND CEILING, ITEM NO: R11, 192, EA; LI 009, MOTORPOOL #2 BUILDING: ADUSTABLE SHELVING, SIZE: 16"D X 2"LIP, 3 ROWS BOTH END WALLS., 48, EA; LI 010, MOTORPOOL #2 BUILDING: EXPLOSION VENTING SKYLIGHT PANELS, ITEM #EVP-SKY, 3, EA; LI 011, MOTORPOOL #2 BUILDING: SELF CONTAINED EYE WASH STATION, ITEM #EW-SC, 1, EA; LI 012, MOTORPOOL #2 BUILDING: DRY CHEMICAL FIRE SUPPRESSION SYSTEM, ITEM #DC, 1, EA; LI 013, MOTORPOOL #2 BUILDING: DIAMOND PLATE STEEL LOADING RAMP, SIZE: 4' X 7' LONG, ITEM #LR, 1, EA; LI 014, FLIGHTLINE BUILDING: HAZARDOUS MATERIAL STORAGE BUILDING, FOUR HOUR FIRE RATED, SIZE: 24'6" X 8'6" X 9'0" HIGH, STANDARD EQUIPMENT. TWO PART CHEMICAL RESISTANT EPOXY PAINT INTERIOR AND EXTERIOR. POLYURETHANE TOP COAT ON EXTERIOR. SIX AIR CHANGES PER HOUR NATURAL VENTILATION. EXTERIOR GROUND CONNECTION. CORRISION RESISTANT EPOXY COATED STEEL GRATE FLOORING, FORKLIFT POCKETS, DOOR EQUIPPED WITH UL LISTED SELF-CLOSING DEVICE, KEYED LOCK AND INTERIOR SAFETY RELEASE. ALL VENTS EQUIPPED WITH UL LISTED 3 HOUR FUSIBLE LINK DAMPERS. SEISMIC TIE DOWN PADS, ONE SET OF 6'0"W X 6'8"H DOUBLE DOORS, 3 HOUR FIRE RATED. MODEL NO: LFR48, 1, EA; LI 015, FLIGHTLINE BUILDING: INSULATION IN WALLS AND CEILING, ITEM #R11, 192, EA; LI 016, FLIGHTLINE BUILDING: ADJUSTABLE SHELVING, SIZE: 16"D X 2"LIP, 3 ROWS BOTH END WALLS, 48, EA; LI 017, FLIGHTLINE BUILDING: EXPLOSION VENTING SKYLIGHT PANELS, ITEM #EVP-SKY, 3, EA; LI 018, FLIGHTLINE BUILDING: SELF CONTAINED EYE WASH STATION, ITEM #EW-SC, 1, EA; LI 019, FLIGHTLINE BUILDING: DRY CHEMICAL FIRE SUPPRESSION SYSTEM WITH ALARM BELL, ITEM #DC/AB, 1, EA; LI 020, FLIGHTLINE BUILDING: DIAMOND PLATE STEEL LOADING RAMP, SIZE: 4' X 7' LONG, ITEM #LR, 1, EA; LI 021, FLIGHTLINE BUILDING: ELECTRICAL INTERLOCK SYSTEM, ITEM #EIS, 1, EA; LI 022, FLIGHTLINE BUILDING: HAZARDOUS LOCATION INTERIOR LLIGHTS, ITEM #IL, 2, EA; LI 023, FLIGHTLINE BUILDING: 19,000 BTU HAZARDOUS LOCATION A/C UNIT, ITEM #A/C, 1, EA; For this solicitation, USA ACA Ft. Stewart intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. A Seller may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. USA ACA Ft. Stewart is taking this action in an effort to improve both seller access and awareness of requests and the agency's ability to gather multiple, completed, real-time bids. All responsible Sellers that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com. Sellers that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Sellers that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Sellers may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process. Should Sellers require additional clarification, contact FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com. Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Buyers and Sellers understand that FedBid ranks all bids by price; however, pursuant to applicable acquisition regulations and/or departmental guidelines, Buyers may use criteria other than price to evaluate offers. Accordingly, please note that, unless otherwise specified herein below, to the extent required by applicable regulations and/or guidelines, award will be made to the responsible Seller whose offer conforming to the solicitation will be most advantageous to the Buyer on the basis of price, technical capability, delivery, and past performance. Contact ClientServices@FedBid.com or call 1-877-9FEDBID to address any questions or comments New equipment ONLY, NO remanufactured products Bid MUST be good for 30 calendar days after submission FOB Destination CONUS (CONtinental U.S.) No partial shipments unless otherwise specified Seller must register with the Central Contractor Registry (CCR) prior to receipt of order. Information can be found at www.ccr.gov
 
Web Link
www.fedbid.com (b-61991, n-10694)
(http://www.fedbid.com)
 
Place of Performance
Address: HUNTER ARMY AIRFIELD, GA 31409
Zip Code: 31409
Country: US
 
Record
SN01514914-W 20080224/080222224605 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.