Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 21, 2008 FBO #2278
SOLICITATION NOTICE

41 -- HVAC SYSTEM

Notice Date
2/19/2008
 
Notice Type
Solicitation Notice
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Space Command, 45CONS (Bldg 423), 1201 Edward H White II St MS 7200, Patrick AFB, FL, 32925-3238, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
FA2521-08-T-0104
 
Response Due
3/3/2008
 
Archive Date
3/18/2008
 
Point of Contact
Bonnie Pruett, Contract Specialist, Phone 321-494-5990, Fax 321-494-5136, - Shelley Hall, Supervisory Contracting Officer, Phone 321-494-4394, Fax 321-494-5136
 
E-Mail Address
bonnie.pruett@patrick.af.mil, shelley.hall@patrick.af.mil
 
Description
This is a synopsis for a commercial acquisition using simplified acquisition procedures (Reference FAR Parts 12 and 13). THIS IS A SYNOPSIS AS REQUIRED BY FAR PART 5.2. THIS IS NOT A REQUEST FOR PROPOSAL (RFP). VENDORS SHOULD NOT SUBMIT FORMAL PROPOSALS UNTIL THE RFP IS POSTED TO THIS WEBSITE. 45 CONS/LGCB has a requirement for a 25 ton HVAC system complete with matching air handler and condenser, cooling 300,000 BTU/s, no heat, air handler with filters mixing box, consisting of outside dampers, return air dampers and a 2 in. filter to supply a constant 1800 CFM of outside air. Must have double wall construction to protect the 1.5 lbs. PSF density of insulation between the walls with 2in. filters before the return air dampers. DDC controller for variable air volume control between air handler and condensing unit. Cooling coil to have copper tube and aluminum fins with stainless steel coil casings and drain pan. Noise and vibration isolated supply fan and motor, condenser shall have suction service valves and electrical disconnect switch (non-fused) and DDC variable volume control, complete corrosion protection coating on condenser coils, 2 to 5 year compressor warranty, voltage for air handler and condensing unit to be 208/230 volts, 3 phase, 60 HZ. Must have separate motorized actuators on outside air and return dampers; quantity: 1 each. The requested delivery to Patrick Air Force Base, Florida will be approximately thirty (30) days after receipt of an award. The government intends to make a single award to the lowest priced, technically acceptable offeror. Solicitation No. FA2521-08-T-0104 is issued as a Request for Proposal. It is advertised with a Standard Industrial Code (SIC) of 3585, business size of 750 employees and a North American Industry Classification System (NAICS) code of 333415. The non-manufacturer rule applies to this requirement since the manufacturer for the referenced NAICS code is a large business. All responsible sources may submit a proposal, which shall be considered by the agency. The solicitation will be issued electronically on or about 26 February 2008 at www.fbo.gov. Proposals may be submitted via hard copy, fax (321-494-5136), or e-mail. NO HARD COPIES OF THE SOLICITATION WILL BE ISSUED FOR ANY REASON. Anticipated award date will be on or about 3 March 2008. The point of contact is Bonnie Pruett, 45 CONS/LGCBB, 1201 Edward H. White II, Street MS7200, Patrick AFB, FL 32925, (321) 494-5990, bonnie.pruett@patrick.af.mil.
 
Place of Performance
Address: PATRICK AIR FORCE BASE, FLORIDA
Zip Code: 32925
Country: UNITED STATES
 
Record
SN01511679-W 20080221/080219223757 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers