Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 08, 2007 FBO #2173
SOLICITATION NOTICE

N -- Install safety devices in 3 boilers

Notice Date
11/6/2007
 
Notice Type
Solicitation Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Veterans Affairs;Lebanon VA Medical Center, Room 117;1700 South Lincoln Ave, Bldg 18;Lebanon PA 17042
 
ZIP Code
17042
 
Solicitation Number
VA-244-08-RQ-0038
 
Response Due
11/20/2007
 
Archive Date
1/19/2008
 
Point of Contact
Rodney Hackman, Utility Plant Supervisor 717-272-6621 ext. 4707
 
E-Mail Address
Email your questions to Contract Specialist
(sally.bentz@med.va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Provide all labor, materials, equipment, supervision, and quality assurance necessary to install safety devices on 3 boilers located in utility plant building 10 in order to comply with the Department of Veterans Affairs (VA) directive 2003-050 and to comply with VA central office contracted inspection firm Boiler Efficiency Institute's recommendations, in accordance with the following specifications: 1. Performance of the following work; a. modify piping of low water cut out LWCO) to allow auxiliary LWCO to have separate connection at vessel; b. rewire limit string to assure the only automatic recycling interlock is the operating pressure control. All other interlocks shall create a lockout; c. modify gas trains to include lockable test cocks, which includes: (1) adding a low gas pressure switch to pilot line; (2) adding lockable shutoff valves to nitrous oxide vent lines; (3) changing main gas safety shutoff valves to incorporate proof of closure switches; d. modify oil lines, which includes: (1) adding oil pressure switches; (2) adding atomizing differential pressure (DP) switches; (3) adding proof of closure switches on main oil valves; e. relocate combustion air switch sensing line from wind box to burner register; f. furnish and install combustion air DP switch and two separate sensing points; g. furnish and install current relays to forced draft (FD) fan interlock circuit; h. furnish and install micro-switch to create physical interlock at air linkage damper; i. furnish and install new low furnace pressure interlock switch; 2. all work is to be in accordance with the National Electric Code/any other applicable codes; 3. dispose all debris caused by this work off station; 4. perform thorough cleaning of any area affected by this work when work has been completed. Patch/repair/paint as necessary any building components/equipment/furniture damaged due to this work; 5. coordinate work with Rodney Hackman, Utility Plant Supervisor @ 717-272-6621 x4707
 
Place of Performance
Address: VA Medical Center;1700 S. Lincoln Avenue;Lebanon, PA
Zip Code: 17042
Country: USA
 
Record
SN01447365-W 20071108/071106223635 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers