Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 01, 2007 FBO #2105
SOLICITATION NOTICE

13 -- Burster Tube and Cap to include loading of Burster Tube for M98/M99 Grenade

Notice Date
8/30/2007
 
Notice Type
Solicitation Notice
 
Contracting Office
RDECOM Acquisition Center - Pine Bluff, ATTN: AMSSB-ACP, 10020 Kabrich Circle, Pine Bluff, AR 71602-9500
 
ZIP Code
71602-9500
 
Solicitation Number
W911RP-07-R-0032
 
Response Due
10/15/2007
 
Archive Date
12/14/2007
 
Small Business Set-Aside
N/A
 
Description
Burster Tube and Cap to include loading of Burster Tube, 158,400 each for theM98/M99 Grenade. The following drawings and specifications are applicable for the Burster Tube: Dwg 13-19-747; FED-STD-H28 and ASME Y14.5. The following drawings and speci fications are applicable for the Burster Cap: 13-19-746 and ASME Y14.5. The contractor shall also be responsible for loading the burster tube with flash mix (KCLO/AL, Dwg 12972326). The type of contract shall be firm fixed price. Solicitation shall con tain an option to purchase up to 100% of the initial quantity. The First Article (FA) Lot size shall consist of 100 each Burster Caps and 100 each of the Burster Tubes. All First Article lot samples shall be taken from a steady state normalized run, of w hich no FA lot samples may be taken during start-up or shut-down process operations. Further, the contractor is not to perform any special trimming and/or secondary operations to the FA sample which will not be performed on EVERY future production unit. The FA lot sample shall represent exactly what is to be expected of future production, and contractor will be held to same. From that FA lot, a random sample of 32 units each shall be sampled by the Government for verification purposes. The contractor is required to perform all required measurements for all components and assemblies and submit a FAT report detailing all of those measured inspections. Every requirement of every drawing and specification must be measured and reported. Also, all required Ma terial Certifications along with Certificates of Analysis are to be included in the FA report. All 64 FAT sample units and assemblies will be individually marked for identification purposes, and the accompanying FAT report will list each unit along with a ll required drawing and/or specification requirements. The FAT report along with the identified FA units will be presented to the Government for verification purposes at the time of the FAT. The FA Test for loading of the burster tubes shall be in accorda nce with Quality Assurance Provisions (QAP) dtd 11 Jul 2006. The government intends to visit the contractors facility to witness first-article testing. FOB Destination, Pine Bluff Arsenal, AR. Acquisition is being conducted utilizing full and open comp etition. All responsible sources may submit a proposal which shall be considered by the agency. The solicitation document contains information that has been designated as Militarily Critical Technical Data. Only businesses that have been certified by the Department of Defense, United States/Canada Joint Certification Office, and have a valid requirement may have a copy of the solicitation documents. All requests for copies of the solicitation document must include a certified copy of DD Form 2345, Militari ly Critical Technical Data Agreement. To obtain certification, contact: Commander, Defense Logistics Information Service (DLIS), ATTN: U.S./Canada Joint Certification Office, 74 Washington Avenue North, Battle Creek, MI 49017-3084 or call the DLIS at (800) -352-3572. The DLIS Unites States/Canada Joint Certification Lookup service is available via the Internet at: http://www.dlis.dla.mil/jcp/. Solicitation will issue on or after 13 Sep 2007 with a closing date on or after 15 October 2007. Requests for the solicitation package must be in writing, via facsimile to 870/540-3730 or via e-mail to pam.burton@us.army.mil . Ensure solicitation number W911RP-07-R-0032 is listed in the subject line on all solicitation requests and provide required DD 2345. Additio nally, companies full mailing address, telephone and fax numbers, and email addresses where available should be listed on all requests. Email request that do not contain the solicitation number in the subject line will be deleted without review. Electro nic Proposals are not acceptable; proposals shall be mailed to arrive by the time specified in the solicitation to the address specified in the solicitation. O fferors shall submit all technical questions regarding this solicitation to the Contracting Officer, in writing, no later than 15 days after issuance of this Request for Proposal. Questions may be sent via facsimile or email, again the solicitation number MUST BE referenced in the subject line on any correspondence. Verbal questions will not be addressed. Point of contact is Pamela J. Burton, Contract Specialist, 870-540-4074.
 
Place of Performance
Address: RDECOM Acquisition Center - Pine Bluff ATTN: AMSSB-ACP, 10020 Kabrich Circle Pine Bluff AR
Zip Code: 71602-9500
Country: US
 
Record
SN01390912-W 20070901/070830222207 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.