Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 02, 2007 FBO #2014
SOURCES SOUGHT

Y -- P-806C Hurricane Relief-Diagnostic Imaging Center Radiation Oncology Clinic, Keesler Air Force Base, Biloxi, MS

Notice Date
5/31/2007
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC Southeast, South, 2155 Eagle Drive, North Charleston, SC, 29406, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-N69450-IPTGC-RE2
 
Response Due
6/13/2007
 
Archive Date
6/28/2007
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE IS NO SOLICITATION; SPECIFICATION, OR DRAWING AVAILABLE for this project at this time. The Reference Number for this announcement is N69450-IPTGC-RE2. The Government will use responses to this Sources Sought Market Survey to make an appropriate acquisition decision. CONTRACT TYPES www.wbdg.org-The Government anticipates awarding a 100% Plans and Specification Construction Contract for P-806C Hurricane Relief-Diagnostic Imaging Center Radiation Oncology Clinic, Keesler Air Force Base, MS within the next several months. EVALUATION CRITERIA ? Provide information on your firm?s experience, past performance and financial strength to handle this contract. Also provide information on your staffing plan and work approach that will give the Government a high level of confidence that the work will be completed within project completion time, within budget constraints, and at the same time meet the Governments quality expectations. The estimated cost for this construction project is between $11,000,000 and $12,000,000. Indicate your firms capability in the type work listed below: PROJECT DESCRIPTION: The project includes a 12,863 SF clinic, a 1,682 SF (approximately 121 foot long) connector to the existing hospital, and a 1,596 SF Entry/Drop-off. This project will provide an elevated one-story steel frame and concrete addition on pile foundations, with a concrete slab, concrete and glass exterior, a modified bitumen roof, and all mechanical and electrical systems. It will be an adequately sized, efficient, modern, hurricane-protected Diagnostic Imaging Center for the Radiation Oncology Clinic to serve the eligible beneficiaries in the Biloxi/Gulfport MS area. The project also includes two linear accelerator vaults, a simulator room, exam rooms, physician offices, physicists' work areas and offices with support spaces. With greater building heights being required by the linear accelerators with their vault shielding requirements, floor to floor heights are separate and independent of the existing hospital building. An enclosed connector corridor ties the new addition back to the hospital's outpatient clinic through a vertical circulation element of the existing hospital. Expressly list the following as technical requirements demonstrated on similar type projects completed in the last 3 years. The vaults require specialized high-density concrete varying from 3.5 to 8 feet thick, placed at walls and roof. The vaults require special shielded doors, containing lead plate and borated panels, weighing between 3000 and 5000 pounds each. The doors are electrically operated. The Simulator Room will contain a CT scanner, which requires specialized shielding in the walls. The Lin Acc?s require special power conditioning gear (electrical) for the power supply. High-end finishes to compete with private sector radiation oncology facilities. This has resulted in the selection of several unusual finish systems and decorative items/devices. The building directly connects to a working hospital. Systems are all tied to the hospital systems (plumbing, med gas, elect, chilled water, steam, comm. and fire alarm/mass notification. The construction duration will be less than or equal to 545 calendar days from date of contract award. EVALUATION CRITERIA - Provide information on your firm?s experience, past performance and financial strength to handle this contract including any Joint venture or mentor-prot?g? relationships. Also provide information on your logistics plan, staffing plan, and work approach that will give the Government a high level of confidence that the work will be completed within project time and budget constraints and will meet the Government?s quality expectations. A. Provide information concerning your Experience on similar projects and how well you Performed on those projects: ? Up to three similar Medical Facility projects with one being completed within the last 3-years- to include a description of the project, construction cost, completion date, information demonstrating satisfactory performance, and contact information for references. ? Describe your firms overall construction experience on Medical Facilities. B. Provide the following Financial information: ? Letter from your surety indicating your bonding capacity for a single project and total aggregate bonding capacity. ? Letter from your bank specifying the amount of your line of credit and amount available under this line. ? Provide the first page of your Central Contractor Registration (CCR) profile from www.ccr.gov. ? Identify business category: large or small (if small indicate which if any of the following Federal government sub-categories apply to your firm; Veteran Owned Small Business, Service Disabled Veteran-Owned Small Business, HUBZone Small Business, Small Disadvantaged Small Business, 8(a) certified Small Business or Woman Owned Small Business). C. Provide narrative of a Logistics Plan that addresses the following: ? Identify major materials, including likely sources and storage locations for equipment that will require long lead time and large volumes. ? Identify the strategy for berthing and meal provisions of the entire workforce. D. Provide a Staffing Plan that addresses the following: ? Organizational Chart that identifies the key personnel and individuals on the construction team that show clear lines of authority, responsibility, and communication between corporate staff, key on-site staff, and subcontractor interface o Provide resumes of key personnel. ? Identify work that will be typically self performed as well as necessary subcontractors ? Indicate relationship that exists with the subcontractors or the means in which others will be established ? Provide evidence that you can provide an appropriate workforce (skilled & unskilled) in this market. Provide narrative of a Work Approach that addresses the following: ? Familiarity with the difficulties, uncertainties and risks associated with the work and identify risk mitigation strategies (i.e., long lead items, etc.) ? Management techniques that have been used for early detection/resolution of issues concerning differing site conditions, customer requested changes, etc. ? Provide techniques that may be used to minimize time growth. THE CLOSING DATE FOR SUBMITTING THE ABOVE CRITERIA IS TUESDAY, 13 June 2007 AT 2:00 p.m. (EDT). The number of submittals required is one original and two copies. Electronic submissions will not be accepted. The address for submitting your package in regards to this Sources Sought Market Survey is? NAVAL FACILITIES ENGINEERING COMMAND, SOUTHEAST, ATTN: MS RHONDA EARNEY, CODE IPTGC/REE, P. O. BOX 190010 N. CHARLESTON, S.C. 29419-9010. FOR FEDERAL EXPRESS PURPOSES 2155 EAGLE DRIVE, N. CHARLESTON, S. C. 29406. POINT OF CONTACT MS RHONDA EARNEY, Contract Specialist, telephone 843-820-5618. FAX NULL, EMAIL Rhonda.earney@navy.mil. Ms. Shirley Shumer, Program Management Assistant, phone 843-820-5923, EMAIL: Shirley.shumer@navy.mil
 
Place of Performance
Address: Keesler Air Force Base, Biloxi, MS
Zip Code: 39534
Country: UNITED STATES
 
Record
SN01306729-W 20070602/070531221438 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.