SOLICITATION NOTICE

66 -- Closed Cycle Refrigerator

Notice Date
4/10/2007
 
Notice Type
Solicitation Notice
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, 96th Contracting Squadron (Eglin AFB), 96th Contracting Squadron 205 West D Ave., Suite 541, Eglin AFB, FL, 32542-6862, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-F1TBAP7086A001
 
Response Due
4/19/2007
 
Archive Date
6/6/2007
 
Small Business Set-Aside
Total Small Business
 
Description
The 96th Contracting Squadron, Eglin AFB, Florida intends to award a Firm-Fixed Price (FFP) contract for the purchase of 1 each, 4 Kelvin Closed-Cycle Refrigerator in support of the Air Force Research Laboratory (AFRL) for its Helium Nanodroplet project. This is a 100% Small-Business setaside combined synopsis/solicitation for commercial items and this procurement is prepared and conducted in accordance with Far Part 12.6 and 13.5 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The announcement number is F1TBAP7086A001. This solicitation is issued as a Request for Quotation (RFQ). The North American Industry Classification Systems (NAICS) code for this acquisition is 333415, with a small business size standard of 750. Please identify/confirm your business size in your response based upon this standard. This purchase request shall meet the following specifications/requirements: (1) Basic Requirement: A 4 Kelvin, closed-cycle refrigerator. This refrigerator system shall be complete and include the cold head, compressor, hoses, and cabling. (2) Coldhead Specifications: A two-stage coldhead is required for the refrigerator system and the second stage must have a cooling power of at least 1.5 Watts at 4.2 Kelvin. The cool down time from room temperature to 4.2 K for the second stage shall be less than 75 minutes. (3) Compressor Specifications: A water cooled compressor capable of driving the cold head is required. The compressor shall consume 3 phase 220 VAC at 60 Hz. (4) Serviceability and Warranty: Vendor will clearly describe which parts are covered under the standard Warranty, the duration of the standard Warranty. Vendor is invited to propose as an option an extended Warranty plan which will cover all parts, labor, and travel charges for a limited time period. (5) Vendor will provide all interconnection hoses/cables and power cables required for operation. The length of such hoses and cables must be at least 5 meters in length and shall not exceed 20 meters in length. (6) Delivery is required ARO no later than 1 June 2007. The following incorporated provisions and clauses are incorporated in this notice and are those in effect through Federal Acquisition Circular 2005-16, effective 22 March 2007; FAR 52.212-1, Instructions to Offerors-Commercial Items-(Sep 2006), and any addenda to the provision as listed in this notice; 52.212-2, Evaluation-Commercial Items-(Jan 1999), evaluation will be based on the following factor: Lowest Price Technically Acceptable (LPTA); 52.212-3, Offeror Representations and Certifications-Commercial Items-(Nov 2006), Offerors must submit a complete copy with their offers. To obtain an electronic copy of 52.212-3, visit the following website: http://farsite.af.mil, or contact Mike DeNamur at the below email address); 52.212-4, Contract Terms and Conditions-Commercial Items-(Feb 2007), and any addenda to the provision as listed in this notice; 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items-(Mar 2007); 52.232-33, Mandatory Information for Electronic Funds Transfer Payments-(Oct 2003); 52.247-34, F.O.B. Destination-(Nov 1991); 52.252-2, Clauses Incorporated by Reference-(Feb 1998); DFARS 252.225-7001, Buy American Act and Balance of Payments Program-(Jun 2005); 252.204-7004, Required Central Contractor Registration (CCR)-(Nov 2003); 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders applicable to Defense Acquisitions of Commercial Items-(Mar 2007). To view the provisions and clauses in full text, visit the website: http://farsite.af.mil. Vendors MUST be registered in Central Contractor Registration (www.ccr.gov) before an award can be made. The quote format is at the discretion of the offeror. All responses must be received No Later Than (NLT) 4:00 P.M., Central Standard Time (CST) on 19 April 2007. Send all quotations to Mike DeNamur (Primary at phone 850-882-0339), 205 West D Avenue, Suite 542, Eglin AFB FL, 32542-6864, or by facsimile to 850-882-1680, or by email at michael.denamur@eglin.af.mil.
 
Place of Performance
Address: AFRL/MNME (HERD FACILITY) - F1TBAP, 2306 PERIMETER ROAD, HERD FACILITY, EGLIN AFB, FLORIDA
Zip Code: 32542
Country: UNITED STATES
 
Record
SN01269934-W 20070412/070410220645 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.