Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 28, 2007 FBO #1948
MODIFICATION

41 -- Market Survey for 9,000 through 36,000 British Thermal Unit/Hour (BTU/H) Improved Environmental Control Units(IECUs) Response Date Extension and E-Mail Submission Changes

Notice Date
3/26/2007
 
Notice Type
Modification
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
US Army C-E LCMC, Acquisition Center - Washington, ATTN: AMSEL-AC-W, 2461 Eisenhower Avenue, Alexandria, VA 22331-0700
 
ZIP Code
22331-0700
 
Solicitation Number
W909MY-07-R-IECU
 
Response Due
4/16/2007
 
Archive Date
6/15/2007
 
Point of Contact
Maureen Parsons, 703-325-6093
 
E-Mail Address
Email your questions to US Army C-E LCMC, Acquisition Center - Washington
(maureen.parsons@cacw.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Please note the following e-mail changes for responding to Market Survey W909MY-07-R-IECU. The e-mail has changed from: maureen.parsons@cacw.army.mil to: maureen.parsons@us.army.mil Also, e-mail shall be limited to 14MB rather than 20MB. If response s are larger than 14MB, please separate files into two e-mails. The response date of 26 March 2007 is hereby extended through 16 April 2007. The following is the full Market Survey announcement which includes the above changes: The US Army Communications-Electronics Life Cycle Management Command, Acquisition Center Washington is performing a market survey on behalf of the US Armys Office of the Project Manager Mobile Electric Power to locate sources who have available, or capabi lities to develop, 9k 115/1/60, 18k 208/3/60, 18k 230/1/60, and 36k 208/3/60 Improved Environmental Control Units (IECUs) with the following characteristics: They all shall use R-410A refrigerant. Main performance values for the 9k 115/1/60 are as follows: Operating Temperature range for Cool mode is 0 to 125 degrees F, for Heat mode is minus 50 to plus 80 degrees F; Total Cooling Capacity is 9,000 Btu/hr and Sensible is 7,200 Btu/hr; Heating Capacity is 7,000 Btu/hr; Requird Weight is 180 lbs and Desired i s 160 lbs; External Dimensions are 24 inches (W) x 16 in (H) x 26.5 in (D); Required Maximum Power is 3.2 kW and Desired is 2.0 kW; Minimum Power Factor is 0.85; Maximum Current is 36.4 amps; Evaporator Airflow is 300 SCFM; Static Pressure is 0.125 in wate r gage; Fresh-Air Airflow is 35 SCFM. Main performance values for the 18k 208/3/60 are as follows: Operating Temperature range for Cool mode is 0 to 125 degrees F, for Heat mode is minus 50 to plus 80 degrees F; Total Cooling Capacity is 18,000 Btu/hr and Sensible is 14,400 Btu/hr; Heating Capacity is 13,000 Btu/hr; Required Weight is 250 lbs and Desired is 225 lbs; External Dimensions are 30 inches (W) x 20 in (H) x 28 in (D); Required Maximum Power is 5.0 kW and Desired is 3.8 kW; Minimum Power Factor is 0.85; Maximum Current is 18.2 amps; Evaporator Airflow is 590 SCFM; Static Pressure is 0.25 in water gage; Fresh-Air Airflow is 70 SCFM. Main performance values for the 18k 230/1/60 are as follows: Operating Temperature range for Cool mode is 0 to 125 degr ees F, for Heat mode is minus 50 to plus 80 degrees F; Total Cooling Capacityis 18,000 Btu/hr and Sensible is 14,400 Btu/hr; Heating Capacity is 13,000 Btu/hr; Required Weight is 250 lbs and Desired is 225 lbs; External Dimensions are 30 inches (W) x 20 in (H) x 28 in (D); Required Maximum Power is 5.0 kW and Desired is 3.8 kW; Minimum Power Factor is 0.85; Maximum Current is 28.4 amps; Evaporator Airflow is 590 SCFM; Static Pressure is 0.25 in water gage; Fresh-Air Airflow is 70 SCFM. Main performance valu es for the 36k 208/3/60 are as follows: Operating Temperature range for Cool mode is minus 25 to plus 125 degrees F, for Heat mode is minus 50 to plus 80 degrees F; Total Cooling Capacity is 36,000 Btu/hr and Sensible is 28,800 Btu/hr; Heating Capacity is 30,700 Btu/hr; Required Weight is 395 lbs and Desired is 350 lbs; External Dimensions are 38 inches (W) x 27 in (H) x 35.5 in (D); Required Maximum Power is 10.0 kW and Desired is 6.8 kW; Minimum Power Factor is 0.85; Maximum Current is 36.3 amps; Evaporat or Airflow is 1,250 SCFM; Static Pressure is 0.25 in water gage; Fresh-Air Airflow is 140 SCFM. Note: 9k 115/1/60 indicates 9,000-Btu/hr IECU capable of operating with 115-volt, single phase, and 60 Hz input power and the 18k 208/3/60 indicates 18,000-Btu/hr IECU capable of operating with 208-volt, three phase, and 60 Hz input power. IECUs shall meet EMI requirements and be compatible with chemical protection equipment and operation in contaminated areas. IECUs shall also be operable in sand and dust environment. They shall incorporate up-to-date technology and components, must be easily maintaina ble in the field and contain embedded diagnostics. They must contain safety circuit s and controls to prevent catastrophic damage and must conform to safety and human factors standards. Potential sources must be capable of producing significant quantities during follow on production. The sources should be highly experienced in the area of specialty environmental control, knowledgeable in the area of R-410A refrigerant and possess a proven track record of accomplishments an on-time delivery of specialty environmental control units. For technical questions please contact Mr. Dongik Lee, Phon e: 703-704-2639 and email: dongik.lee@us.army.mil, or Mr. Jeff Taylor, Phone: 703-704-3208 and email: jtaylor@belvoir.army.mil. All responsible sources are requested to submit a response to this market research not to exceed 15 pages, and should include descriptive literature of the product and contractors North American Industry Classification System (NAICS) small business size s tatus. The supporting literature must be in sufficient detail to enable the Government reviewer to determine if the vendor has the required product and production qualifications required for the effort. The small business size standard is 750 employees for the NAICS code 333415. The data received in response to this market survey is for information purposes only and does not mandate or impose requirements. This notice is not a request for proposal and the Government does not intend to pay for information su bmitted. Respondents will not be notified of the results of the evaluation of the information they provide. No contract award will be made on the basis of responses received; however, the information will be used in PM-MEPs assessment of capable sources. It is desirable that data be received with unlimited rights to the Government. However, we recognize that proprietary data may be included with the information provided. If so, clearly mark such proprietary information and clearly separate it from the unre stricted information as an addendum. Responses are to be submitted via e-mail to maureen.parsons@us.army.mil no later than 16 April 2007. Please use the EMAIL SUBJECT: Contractor Name 9 to 36K BTU/H IECU. E-mail shall be limited to 14MB.
 
Place of Performance
Address: US Army C-E LCMC, Acquisition Center - Washington ATTN: AMSEL-AC-W, 2461 Eisenhower Avenue Alexandria VA
Zip Code: 22331-0700
Country: US
 
Record
SN01259353-W 20070328/070326220740 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.