Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 16, 2007 FBO #1936
SOLICITATION NOTICE

H -- clean test adjust,calibrate electrial apparatus.

Notice Date
3/14/2007
 
Notice Type
Solicitation Notice
 
NAICS
423610 — Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
 
Contracting Office
Department of Veteran Affairs;VA Northern Indiana;1700 E 38th Street;Marion IN 46953
 
ZIP Code
46953
 
Solicitation Number
VA-251-07-RQ-0018
 
Response Due
3/23/2007
 
Archive Date
4/22/2007
 
Small Business Set-Aside
Total Small Business
 
Description
the Veterans Administration at VANIHCS at 1700 East 38th Street Marion, In., 46953,and VANIHCS at 2121 Lake Avenue, Fort Wayne, In 46895,are seeking to award a single contract for electrical testing involving cleaning, testing, adjust, calibrate and inspect electrical distribution apparatus. including, but not limited to, power transformers, switchgear, motor control centers, distribution centers, panel boards at the distribution centers, air circuit breaker, vacuum circuit breakers and loop switches at each campus.. Over-current testing apparatus shall be limited to over-current relays for each 15KV and 5KV circuit breaker. Megger voltage shall not exceed IEEE standards. No high pot voltage to be applied to feeder wires. All equipment will be isolated from panel and feeders during testing for proper data reading. NO VARIANCE. Contractor will be responsible to reinstall equipment to original cndition; verifying voltage, phasing and rotation. Any damage to equipment due to neglect is the contractor's financial responsibility. Two assistants and apprentices may be assigned to each campus's project as assistants to certified technicians at a ration not to exceed two (2) certified to one (1) non certified assistant or apprentices. names and certification numbers of registered professional engineer supervising the work and signing the test reports and the supervisiing field service engineer must be provided by the contractor and verified by the contracting officer, before contract award. After contract award similar data for all certified technicians who will be assigned to work on this project must also be submitted and approved before starting work on the contract. contractor will provide three (3) copies of listings to facility's Engineering Office of all devices tested and scanned including complete nameplate data, age, maximum loading in amperes, condition as found and as modified. Notification to facility's Engineering office shall be submitted in writing, describing any conditions, including recommendations for corrective action.. Critical conditions needing immediate correction shall be conveyed verbally to the COTR and included in the final report Separate report shall be provided for each campus **all bidders must visit both sites prior to bidding to familiarize themselves with the equipment to be tested and inspected. Bidders shall also obtain the necessary technical information in the field that may be required to submit a complete bid** all work shall be completed at both campuses and written reports submitted by April 27,2007 or within 30 days from contract award. Contractor can work simutaneously at both campuses.
 
Place of Performance
Address: VA Northern Indiana Healthcare System;1700 E 38th Street and 2121 Lake Avenue;Marion, IN 45953 and Fort Wayne IN 46805
Zip Code: 46953
Country: us
 
Record
SN01250771-W 20070316/070314220738 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.