Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 02, 2007 FBO #1922
SOLICITATION NOTICE

42 -- Fire Door Certification Wilford Hall Medical Center

Notice Date
2/28/2007
 
Notice Type
Solicitation Notice
 
NAICS
541690 — Other Scientific and Technical Consulting Services
 
Contracting Office
Department of the Air Force, Air Education and Training Command, Lackland AFB - 37th Contracting Squadron, 1655 Selfridge Avenue, Lackland AFB, TX, 78236-5253, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
F2MTW56319A100
 
Response Due
3/7/2007
 
Archive Date
3/15/2007
 
Point of Contact
Richard Webster, Contract Specialist, Phone (210)671-0792, Fax 210-671-0674, - Tracy Harris, Contract Specialist, Phone (210)671-6085, Fax (210)671-3179,
 
E-Mail Address
richard.webster@lackland.af.mil, tracy.harris@lackland.af.mil
 
Description
The 37 Contracting Squadron intends to award a contract to evaluate and certify the Fire Doors and Frames at Wilford Hall Medical Center. Work will be in accordance with the Statement of Work and commence on or about 19 March through 19 May 2007.This is a combined synopsis/solicitation for commercial service prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation, F2MTW56319A100, is being issued as a Request for Quotation (RFQ), however, to qualify you must have participated in the site visit done on 22 Feb 07. Vendors must be licensed and certified to evaluate and certify Fire Doors in IAW NFPA 80: Standard of Fire Doors and Other Opening Protectives; NFPA101: Life Safety Code; NFPA 252: Standard Methods of Fire Tests of Door Assemblies. Proof of licensing and certification will be required and should be submitted with your quotation. The North American Industry Classification System (NAICS) code is 541690. All prospective offerors interested in submitting a quote must be registered with the Central Contractor Registration (CCR) and have a commercial and government entity code (CAGE Code). All responsive offerors will be considered by the agency. Paper copies will not be available. Once the solicitation is posted, it is incumbent upon the interested parties to review this site frequently for any updates/amendments to any and all documents. STATEMENT OF WORK Fire Door Inspection, Testing and Labeling GENERAL The Contractor shall provide all personnel equipment, tools, materials, supplies, and labor supervision necessary to inspect, test and re-label existing fire doors and fire assemblies at Building 4550 at Lackland AFB as defined by this Statement of Work. REFERENCES: NFPA 80: Standard for Fire Doors and Other Opening Protectives; NFPA 101: Life Safety Code (2000); NFPA 252: Standard Methods of Fire Tests of Door Assemblies (or UL 10C); 1.1 SPECIFIC REQUIREMENT 1.1.1 Evaluate existing conditions of all fire doors and frames along fire and smoke partitions as well as stairwell doors as identified on government provided floor plans. Determine if doors and frames are in compliance with NFPA 80. Remove paint that is covering any door or frame label to bring doors into compliance. 1.1.2 Provide summary report of fire doors and frames. At a minimum, report shall include the following (if available)1.1.2.1 Door # (i.e. 1E07); 1.1.2.2 Type of Door (i.e. Hollow Metal, Solid Core Wood, etc), Type Frame 1.1.2.3 Manufacturer 1.1.2.4 Label missing from door (Y/N), frame (Y/N) 1.1.2.5 Required Fire Rating of Door and Frame based on NFPA 80 and NFPA 101 1.1.2.6 Identify whether door or frame with missing label can have a fire rating determined by comparison of doors with proper labels (same construction), nondestructive testing, and/or representative destructive testing (requires coordination and approval by Government before proceeding with any testing). 1.1.2.7 Identify if repairs needed to door or frame to make NFPA compliant; 1.1.2.7.1 If door or frame not compliant,list all discrepancies and recommendations on how to correct 1.1.3 Upon approval of the summary report in para 1.1.2 perform testing necessary to determine fire rating of door and frames with missing labels. 1.1.3.1 Provide summary report of fire doors and frames test results used to determine fire rating 1.1.4 Provide and install new labels to doors and frames that are missing labels and are determined to be in compliance with NFPA. Labels shall be from a nationally recognized fire testing laboratory. 1.1.5 Remove paint from labels painted over without damaging the label. Mechanical methods of removing paint can be used on embossed labels. Non-embossed labels should have paint removed with chemical method. 1.1.6 Perform secondary evaluation of all doors and frames determined to be non compliant with NFPA after discrepancies have been corrected. 1.1.6.1 Provide and install new labels to doors and frames determined to be NFPA 80 compliant after secondary evaluation. The provision FAR 52.212-2, Evaluation-Commercial Items, is applicable to this solicitation and the blanks in section (a) are completed as follows: Price considerations. Offerors shall include with their quotes, a completed copy of Offeror Representations and Certifications--Commercial Items from on-line at https://www.bpn.gov,. FAR 52.212-4, Contract Terms and Conditions--Commercial Items, 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders--Commercials Items, 252.232-7003,Electronic Submission of Payment Request, and 252.204-7004,Required Central Contractor Registration, are applicable to this acquisition. The full text of these clauses may be accessed electronically at this address: http://FARSITE.HILL.AF.MIL.VFFARA.HTML. Responses to this RFQ must be received via fax or e-mail to Mr Richard Webster Ph#: (210) 671-0792; fax#:210-671-0674; email: richard.webster@lackland.af.mil by 28 Feb 07 no later than 3:00PM Central Standard Time at the 37th Contracting Squadron, 1655 Selfridge Ave., Lackland AFB, TX 78236-5253. Vendors not registered in the Central Contractor Registration (CCR) database prior to award will be ineligible for award.
 
Place of Performance
Address: Wilford Hall Medical Center, 2200 Bergquist Dr.; Lackland AFB, Texas, POC: Richard Anaya, Facilities Director; 292-6575
Zip Code: 78236
Country: UNITED STATES
 
Record
SN01240729-W 20070302/070228220734 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.