Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 17, 2007 FBO #1909
SOLICITATION NOTICE

52 -- Videoprobe Measurement System

Notice Date
2/15/2007
 
Notice Type
Solicitation Notice
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
166 AW/LGC, 2600 Spruance Drive, Corporate Commons, New Castle, DE 19720-1615
 
ZIP Code
19720-1615
 
Solicitation Number
W912L5-07-T-0001
 
Response Due
3/5/2007
 
Archive Date
5/4/2007
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis solicitation for the purchase of commercial items, prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR13.5, as applicable and as supplemented with additional information included in this not ice. This announcement constitutes the only solicitation. Quotes are being requested and a written solicitation will be issued. Solicitation number W912l5-07-T-0001 is applicable and is issued as a request for quotations. The solicitation and incorpora ted provisions and clauses are those in effect through Federal Acquisition Circular. Requirement is 100% Unrestricted. The NAIC code is 334519, SIC code 3829. Brand Name or Equal is applicable. Destination pricing required. The location for delivery is the AASF, 33 Corporate Circle, New Castle, Delaware 19720. POC is James J. McDaniel. 302-326-7217. Award would be based on lowest price, technically acceptable. Delivery shall be made within 30days or less after receipt of order(ARO). If quoting an equ ivalent item, please email the description with specifications of the item you are quoting. The Contracting Officer will evaluate equal products on the basis of information furnished by the quote or identified in the quote and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the quote. The description of the commercial item is XGL3 Video probe Measurement with accessories. Clin 0001 Everest XLG3 Video P robe Measurement System or Equal l (1 ea). XLG3000 Base Unit, w/Digital Image and Video storage, I/O includes: (3) USB-2 ports, (2) PC card bus ports, S Video input and output, VGA output, audio input and output, AC input and output, DC input and output. Features include: Portable operation, optional DVD recorder, expandable internal memory, integrated insertion tube storage reel, handset docking point, carrying and tie down rings, 75 watt HID lamp, MPEG 2 VIDEO COMPRESSION, JPEG AND BITMAP STILL IMAGE F ORMATS. Video Output is switch able NTSC and Pal. Networking and Ethernet port operation are optional software features. Clin 0002 XLG3 Handset with integrated wide VGA 7inch color LCD (1 ea), single joystick for articulation and menu control, control b uttons, audio microphone. Includes 16:9, and 4:3 viewing. Accepts any XLG3 Probe. Handset cable is 2.4 meter (8 feet) long. Clin 0003 XLG3A512MIC Internal memory card for XLG3 CPU (1 ea). Contains XLG3 Operating System software and 100 MB user memory f or internal storage of still images and motion video. XLG3P6130 XLG3, XLG3 Probe Clin0004 6.1mm diameter, 3.0 meter length. Interchangeable probe, insertion tube for XLG3 system (1 ea). Head guard included. Optical Characteristics: 50mm to infinity de pth of field, 50 degree field of view. 150 degree minimum articulation. Includes probe case and tip case. Clin 0005 XLG3T61120FG, Optical Tip for 6.1mm probe (1ea.) Forward view. General purpose 120 degree FOV, 5mm 120mm DOF color code: black letteri ng: Clin 0006 XLG3T61120SG Optical Tip for 6.1mm probe. Side view. General Purpose 120 degree FOV, 4mm -100mm DOF color code: blue. Clin 0007 XLG3TM615050SG (1 ea), Side View Stereo Measurement tip for all XLG3 6.1mm probes. Optical characteristics: 2mm to 50mm depth of field, 50 x 50 degree field of view. Requires installation of XLG3SMEAS measure software in the XLG3000 Base Unit. Color Blue. Clin 0008, XLG3TM616060FG (1 ea), XLG3 Forward View Stereo Measurement Tip, forward view, stereo measur ement tip for all XLG3 6.1mm probes. Optical characteristics: 4mm to 80mm depth of field, 60 x 60 degree field of view. Clin 0009Requires installation of XLG3SMEAS measurement software in the XLG300 base unit. Color: Black. XLG3TM61VER (1 ea) Measurement Verification Block: Stereo and shadow measurement verification block. This NIST traceable tool contains verifiable m easurement targets used to check th e accuracy of XLG3 Video Probe measurement optics. Clin 0010, XLG3SMEAS (1ea) Measurement Software: Stereo, shadow, and comparison measurement software for the XLG3 system. Stereo measurement capabilities of: Distance, depth, area, point to line, and m ulti-segment line length. Shadow measurement capabilities of: Distance, depth, skew, point to line, area, and multi-segment line length. Saves images w/measurement data for enable re-measurement on XLG3, or pc based remeasurement applications. Clin 0011, GTR-603S (1ea) 30.5cm (12 inch rigidizer tube for 6mm probes: Includes XA118 gripper handle ridigizers turn a flexible Video Probe into a rigid. When used with tube grippers and access port couplers a ridgidizer allows for hands free probe positioning. Working section outer diameter 7.92mm (.312inch) Clin 0012 TRAINING Complimentary Product Training (1ea): To include: equipment set-up, maintenance, and proper handling training at no additional charge upon request after all equipment has been received, where appropriate.Clin 0013, IVIEWPC (1ea) Kit Version 5.0: Iview pc software allows the user to: Easily organize images using the thumbnail viewer. Re-measure using comparison technology; generate Microsoft word based inspection reports featuring capt ured images and measurement data. Kit contains: CD Rom and user's manual iview pc kit version 5.0: IVIEW PC software allows the user to: Easily organize images using the thumbnail viewer. Re-measure using either Stereo Probe, Shadow Probe or Comparison technology, generate Microsoft Word based inspection reports featuring captured images and measurement data, Kit contains: CD Rom & User's Manual IVIEW PC Kit Version 5.0: IVIEW PC software allows the user to: Easily organize images using the thumbnail view. Re-measure using either Stereo Probe, Shadow Probe or Comparison technology-Generate Microsoft Word based inspection reports featuring captured images and measurement data. Allows user to import and export from IVIEW PC directly to XLG3 via network ed or direct Ethernet connected IP address. Kit contains: CD Rom & User's Manual. Clin 0014, XLG3ALAMP HID Lamp (1 ea): 75 watt replacement high intensity discharge lamp for XLG3000 base unit. Rated for 1000 hours. Clin 0015 a Trade-In Allowance perc entage to be offered towards the trade in of fiberscope system and purchase of XLG3000 or equal. The following FAR clauses apply: 52.212-4, 52.212-5, 52.252-2, 52.252-6, 52.222-3, 52.222-19, 52.225-1, 52.233-3, 52.253-1, 252.204-7003, 252.204-7004 Alt A, 252.212-7001, 52.253-1, 52.232-36, 52.222-26, 52.233-3. The complete text of the Federal Acquisition Circulars, DFARS Change Notices, and Far DFARS clauses and provisions are available at the following internet site: http://farsite.hill.af.mil or http:// www.arnet.gov/far. All Quoters are to be registered through the Central Contractor Registration (www.ccr.gov)to be considered for selection. Quotes are to be submitted NLT 5 March, 2007, 12:00:00.0 Eastern Time. Solicitation W912L5-07-T-0001 will be avail able for viewing on 15 February 2006. The website is: http://www.nationalguardcontracting.org/ This is a combined synopsis/solicitation for the purchase of commercial items, prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR13.5, as applicable and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested and a written solicitation will be issued. Solicitation number W912l5-07-T-0001 is applicable and is issued as a request for quotations. The solicitation and incorporated pr ovisions and clauses are those in effect through Federal Acquisition Circular. Requirement Unrestricted. The NAIC code is 334519, SIC code 3829. Brand Name or Equal is applicable. Destination pricing required. Award would be based on lowest price, techn ically acceptable. Delivery shall be made within 30days o r less after receipt of order(ARO). If quoting an equivalent item, please email the description with specifications of the item you are quoting. The Contracting Officer will evaluate equal products on the basis of information furnished by the quote or ide ntified in the quote and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the quote. The description of the commercial item is XGL3 Video probe Measure ment w/ accessories. Clin 0001 Everest XLG3 Video Probe Measurement System or Equal l (1 ea). XLG3000 Base Unit, w/Digital Image and Video storage, I/O includes: (3) USB-2 ports, (2) PC card bus ports, S Video input and output, VGA output, audio input and output, AC input and output, DC input and output. Features include: Portable operation, optional DVD recorder, expandable internal memory, integrated insertion tube storage reel, handset docking point, carrying and tie down rings, 75 watt HID lamp, MPEG 2 VIDEO COMPRESSION, JPEG AND BITMAP STILL IMAGE FORMATS. Video Output is switch able NTSC and Pal. Networking and Ethernet port operation are optional software features. Clin 0002 XLG3 Handset with integrated wide VGA 7 inch color LCD (1 ea), single j oystick for articulation and menu control, control buttons, audio microphone. Includes 16:9, and 4:3 viewing. Accepts any XLG3 Probe. Handset cable is 2.4 meter (8 feet) long. Clin 0003 XLG3A512MIC Internal memory card for XLG3 CPU (1 ea). Contains XLG 3 Operating System software and 100 MB user memory for internal storage of still images and motion video. XLG3P6130 XLG3, XLG3 Probe Clin0004 6.1mm diameter, 3.0 meter length. Interchangeable probe, insertion tube for XLG3 system (1 ea). Head guard incl uded. Optical Characteristics: 50mm to infinity depth of field, 50 degree field of view. 150 degree minimum articulation. Includes probe case and tip case. Clin 0005 XLG3T61120FG, Optical Tip for 6.1mm probe (1ea.) Forward view. General purpose 120 degree FOV, 5mm 120mm DOF color code: black lettering: Clin 0006 XLG3T61120SG Optical Tip for 6.1mm probe. Side view. General Purpose 120 degree FOV, 4mm -100mm DOF color code: blue. Clin 0007 XLG3TM615050SG (1 ea), Side View Stereo Measurement tip for all XLG3 6.1mm probes. Optical characteristics: 2mm to 50mm depth of field, 50 x 50 degree field of view. Requires installation of XLG3SMEAS measure software in the XLG3000 Base Unit. Color Blue. Clin 0008, XLG3TM616060FG (1 ea), XLG3 Forward Vie w Stereo Measurement Tip, forward view, stereo measurement tip for all XLG3 6.1mm probes. Optical characteristics: 4mm to 80mm depth of field, 60 x 60 degree field of view. Clin 0009Requires installation of XLG3SMEAS measurement software in the XLG300 base unit. Color: Black. XLG3TM61VER (1 ea) Measurement Verification Block: Stereo and shadow measurement verification block. This NIST traceable tool contains verifiable m easurement targets used to check the accuracy of XLG3 Video Probe measurement optics. Clin 0010, XLG3SMEAS (1ea) Measurement Software: Stereo, shadow, and comparison measurement software for the XLG3 system. Stereo measurement capabilities of: Distance , depth, area, point to line, and multi-segment line length. Shadow measurement capabilities of: Distance, depth, skew, point to line, area, and multi-segment line length. Saves images w/measurement data for enable re-measurement on XLG3, or pc based rem easurement applications. Clin 0011, GTR-603S (1ea) 30.5cm (12 inch rigidizer tube for 6mm probes: Includes XA118 gripper handle ridigizers turn a flexible Video Probe into a rigid. When used with tube grippers and access port couplers a ridgidizer allow s for hands free probe positioning. Working section outer diameter 7.92mm (.312inch) Clin 0012 TRAINING Complimentary Product Training (1ea): To include: equipment set-up, maintenance, and proper handling training at no additional charg e upon request after all equipment has been received, where appropriate. Clin 0013, IVIEWPC (1ea) Kit Version 5.0: Iview pc software allows the user to: Easily organize images using the thumbnail viewer. Re-measure using comparison technology; generate Microsoft word based inspection reports featuring captured images and measurement data. Kit contains: CD Rom and user's manual iview pc kit version 5.0: IVIEW PC software allows the user to: Easily organize images using the thumbnail viewer. Re-measure using either Stereo Probe, Shadow Probe or Comparison technology, generate Microsoft Word based inspection reports featuring captured images and measurement data, Kit contains: CD Rom & User's Manual IVIEW PC Kit Version 5.0: IVIEW PC software allows the user to: Easily organize images using the thumbnail view. Re-measure using either Stereo Probe, Shadow Probe or Comparison technology-Generate Microsoft Word based inspection reports featuring captured images and measurement data. Allows user to import and export from IVIEW PC directly to XLG3 via networked or direct Ethernet connected IP address. Kit contains: CD Rom & User's Manual. Clin 0014, XLG3ALAMP HID Lamp (1 ea): 75 watt replacement high intensity discharge lamp for XLG3000 base unit. Rate d for 1000 hours. Clin 0015 a Trade-In Allowance percentage to be offered towards the trade in of fiberscope system and purchase of XLG3000 or equal. The following FAR clauses apply: 52.212-4, 52.212-5, 52.252-2, 52.252-6, 52.222-3, 52.222-19, 52.225-1, 52.233-3, 52.253-1, 252.204-7003, 252.204-7004 Alt A, 252.212-7001, 52.253-1, 52.232-36, 52.222-26, 52.233-3. The complete text of the Federal Acquisition Circulars, DFARS Change Notices, and Far DFARS clauses and provisions are available at the following internet site: http://farsite.hill.af.mil or http://www.arnet.gov/far. All Quoters are to be registered through the Central Contractor Registration (www.ccr.gov)to be considered for selection. Quotes are to be submitted NLT 5 March, 2007, 12:00:00.0 Eas tern Time. Solicitation W912L5-07-T-0001 will be available for viewing on 15 February 2006. The website is: http://www.nationalguardcontracting.org/. POC for the synopsis is Contracting Officer, Dana K. Danna 302-323-3546. All request for quotes are to be faxed at 302-323-3344 or emailed to dana.danna@denewc.ang.af.mil.
 
Place of Performance
Address: 166 AW/LGC 2600 Spruance Drive, Corporate Commons New Castle DE
Zip Code: 19720-1615
Country: US
 
Record
SN01233077-W 20070217/070215221306 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.