Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 05, 2006 FBO #1805
SOLICITATION NOTICE

J -- BOILER TREATMENT EQUIPMENT

Notice Date
11/21/2005
 
Notice Type
Solicitation Notice
 
NAICS
333415 — Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
 
Contracting Office
DHS - Direct Reports, United States Coast Guard (USCG), Commanding Officer (vpl), USCG Maintenance and Logistics Command - Atlantic, 300 East Main Street Suite 600, Norfolk, VA, 23510-9102
 
ZIP Code
23510-9102
 
Solicitation Number
HSCG80-06-Q-3FA402
 
Response Due
11/30/2005
 
Point of Contact
Sandra Martinez, Contract Specialist, Phone (757) 628-4591, Fax (757) 628-4676, - Vanessa Nemara, Supervisory Contract Specialist, Phone 757-628-4634, Fax 757-628-4676,
 
E-Mail Address
smartinez@mlca.uscg.mil, VNemara@MLCA.USCG.MIL
 
Description
The U.S. Coast Guard Maintenance and Logistics Command, Atlantic, intends to issue a sole source contract to Ashland Specialty Chemical Company to supply a Drew Marine Division - Sample Conditioning, Analysis and Chemical Feed System and associated spare parts in accordance with FAR 6.302-1. This system shall be installed on the USCGC GALLATIN with the option to install the identical system on the USCGC DALLAS. This notice of intent is not a request for competitive quotes. However, all quotes received within 5 days after the date of publication of this synopsis will be considered by the Government. The intent of this notice is to see if there are any other capable sources available to provide these services. Your firm must be able to provide a Sample Conditioning, Analysis and Chemical Feed System consisting of seven (07) major components. The components consist of the following (1) Sentry Model SL-200L Sample Conditioning Panel for controlling the temperature, pressure, and flow rate of the continuous boiler water sample to the adjacent analyzers. The panel shall include : (a) a automatic sample inlet valve to switch the sample source between the boilers 110 VAC, (b) sample cooler – Model TLF-44B5 with stainless steel cooling water inlet & outlet valves (c) the cooler tubing is inconel 625, (c) a 90/10 CuNi for use with seawater cooling service, (d)pressure reducing and flow control valve, (e) Sentry thermal shutoff valve with limit switch to protect analysis equipment and other components from damage, (f) total flow indicator, (g) back pressure/relief valve to maintain constant pressure (h) temperature indicator, (i) pressure relief waste from Back Pressure Relief Valve (j) Sample sink to collect grab sample, (k) flow indicator w/needle flow (0-580 cc/min) to set sample flow rate to flow cells, (l) 1 ph Probe, Thornton Model #303, and (m) 1 conductivity Cell, Thornton Model #240. (2) Analysis & Remote Control Panel consisting of: (a) panel component mounted in an electrical enclosure (approx 38” high X 30” wide), (b) dual channel analyzer, Thornton Model 6822 & 6322 (110 VAC), (c) 2 position selector switch and two indicator lights display selected operating mode, (d) 4 position selector switch to override automatic sampling system (e) remote control module (110 VAC) for remote of analyzer panel and control if the chemical feed pumps, (f) junction blocks for electrical interconnection with modules. (3) Chemical Feed Rack and it shall include (a) 2 chemical drums (25 liter each), 2 metering pumps, prominent model BT5a with two stage suction assy, 2 automatic 3 way pump discharge valves to selectively feed each boiler, (b) Junction Box for wiring pumps and valves (110 VAC), (4) Temperature Element and Temperature Transmitter Sending Unit and it shall include (a) 1 temperature probe 316 stainless steel. Range is 0-150 C . Probe housing, bushing type with ¾: NPT into the tank and ½” NPT for the probe, (b) 24 VDC Transmitter Model 81/82000 4-20 mA. (5) Blowdown Valves – this shall include – 2 Worcester Automatic Blowdown Control Valve VP-300., (6) Treatment Chemical and Manual Testing and recording equipment/software, (7) Remote Logging PC. The Information received will normally be considered solely for the purpose of determining whether to conduct a competitive procurement. NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (21-NOV-2005). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 03-NOV-2006, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/DHS/USCG/COUSCGMLCA/HSCG80-06-Q-3FA402/listing.html)
 
Place of Performance
Address: charleston, sc
 
Record
SN01176254-F 20061105/061103225158 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.