Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 27, 2006 FBO #1766
MODIFICATION

66 -- Temperature/Humidity Test Chamber

Notice Date
9/25/2006
 
Notice Type
Modification
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, CA, 93524-1185
 
ZIP Code
93524-1185
 
Solicitation Number
F1SBAA6179B004
 
Response Due
10/5/2006
 
Archive Date
10/20/2006
 
Point of Contact
Marc Venzon, Contract Specialist, Phone 661-277-2097, Fax 661-275-7871,
 
E-Mail Address
marc.venzon@edwards.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
THE PURPOSE OF THIS MODIFICATION IS TO CORRECT A TYPE ERROR FOR THE TEMPERATURE RANGE. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation is a request for a quote (RFQ). The solicitation document, incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-12 and DFARs Change Notice (DCN) 20060908. This acquisition is a set-aside for small businesses. NAICS code is 334519. Description: The Air Force Research Laboratory has a requirement for nine (9) test chambers with the following specifications. Solicitation is for the commercial purchase of nine test chambers: CLIN 0001 Temperature/Humidity Test Chamber Interior Dimensions: -48-in wide x 48-in deep x 48-in high -5 HP scroll compressor utilizing ?environmentally correct? refrigerant and a local air-cooled condenser -full opening front door, left-hand hinged -24-in x 24-in window in door -heavy duty shelf -solid-state relative humidity transmitter/sensor -ETL (UL STD 508A) approved main power panel -ICM400 (or equivalent) surge protector on main incoming power -set of two refrigeration gauges -interior light -4-in ID access port with silicone barrier port plug -controller interface for customer supplied and wired EuroTherm controller -set of electronic maintenance and installation manuals -13-in stainless-steel access port with silicone-barrier port plug -Barnstead humidity water demineralizer D4511 with E3450 indicator light and replaceable cartridge -replacement cartridge for Barnstead D4511 -distilled water reservoir-5 gallon -5 CFM dry air purge system (Supply Air 100 psig/ 0.375-in NPTF) -chamber door safety limit switch Exterior Dimensions: -74-in wide x 84-in deep x 101-in high CLIN 0002 Explosion Proof Chamber Interior Package -sheath heaters, blow-out port, Class 1 Div 1 Light and non sparkling fans CLIN 0003 Refrigeration Section Quiet Package -lower noise level to 72 dBA as measured 3 feet away at right angles CLIN 0004 Newport Temp Sentry digital high/low limit safety system CLIN 0005 Installation at Air Force Research Laboratory, Edwards AFB, CA Temperature Range: -40 degrees Celsius to + 177 degrees Celsius, +/- 1.1 degree Celsius control accuracy as measured at control sensor after stabilization has been reached. Stabilization has occurred after temperature of the chamber liner changes 2 degrees Celsius or less per hour. Humidity Range: 20% to 95% RH, +/- 5% RH as limited by a + 4.5 degrees Celsius (+40 degrees Fahrenheit) dew point temperature and a maximum dry bulb temperature of + 65 degrees Celsius. Heating & Cooling Performance: The chamber utilizing only mechanical refrigeration and electrical heating, is capable of average air temperature change rates, not linear rates of change, as measured at the control thermocouple. This solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. FAR 52.212-1, Instructions to Offerors-Commercial Items (addendum to paragraph (h): a single award will be made; FAR clause 52.212-2, Evaluation--Commercial Items, the following factors shall be used to evaluate offers: Best Value; FAR clause 52.212-3, Offeror Representations and Certifications - Offerors must include a completed copy of the provision with the offer via the ORCA website. Instructions for completing this requirement can be found by going to website http://orca.bpn.gov/ and http://orca.bpn.gov/help.aspx. In order to register via ORCA, vendor must also have an active DUNS Code (Dunn and Bradstreet - http://www.dnb.com/us/), be actively registered in the Central Contracting Registration (CCR - https://www.bpn.gov/CCR/scripts/index.html) system, and obtain a Marketing Partner Identification Number (MPIN -http://www.ccr.gov/mpin.asp). Offerors shall provide the information required in the clause; clause 52.212-4, Contract Terms and Conditions--Commercial Items; clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders--Commercial Items (to include: 52.222-26, Equal Opportunity; 52.222-35, Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-36, Affirmative Action for Workers With Disabilities; 52.222-37, Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans); clause 52.232-33 Payment by Electronic Funds Transfer--Central Contractor Registration. The following DFAR clauses apply to this acquisition: 252.212 7001, Contract Terms and Conditions Required to Implement Statutes Applicable to Defense Acquisitions of Commercial Items (including 252.225-7001 Buy American Act and Balance of Payment Program); and 252.211-7003 Item Identification and Valuation. Additional information: Technical point of contact is Mike Tinnirello, (661) 275-5506; E-mail: Michael.Tinnirello@edwards.af.mil. Contractual point of contact is Marc Venzon, (661) 277-2097, fax 661-275-7871, E-mail: marc.venzon@edwards.af.mil. Responses must be received no later than (NLT) 1:00 p.m., Pacific Daylight Time, 05 Oct 2006. Responses should be submitted to: Marc Venzon, Air Force Flight Test Center (AFFTC/PKTB), Directorate of Contracting, 5 South Wolfe Avenue, Edwards AFB, CA 93524. Telephone requests to be placed on a mailing list will not be honored. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (25-SEP-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USAF/AFMC/AFFTC/F1SBAA6179B004/listing.html)
 
Place of Performance
Address: EDWARDS AFB, CA
Zip Code: 93524
Country: UNITED STATES
 
Record
SN01154482-F 20060927/060925223324 (fbodaily.com)
 