Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 12, 2006 FBO #1567
SOLICITATION NOTICE

C -- Indefinite Quantity Contract for Mechanical and Electrical Engineering and Design Services for Various Projects and Marine Corps Base, Camp Lejeune, North Carolina

Notice Date
3/10/2006
 
Notice Type
Solicitation Notice
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC Atlantic, ROICC Camp Lejeune, Department of the Navy, Naval Facilities Engineering Command, Mid-Atlantic 1005 Michael Road, Camp Lejeune, NC, 28547-2521
 
ZIP Code
28547-2521
 
Solicitation Number
N40085-06-R-4412
 
Response Due
4/11/2006
 
Archive Date
7/15/2006
 
Description
Three firms will be contracted by this announcement. Solicitation includes, design and engineering services for preparation of construction documents including plans, specifications, cost estimates, record drawings, and review of shop drawings. Projects will require the ability to design demolition, repair, replacement, extension and modification of steam and condensate lines, HVAC systems, plumbing, piping, motors, controls, electrical systems, fire protection systems including fire suppression and reporting systems, medium voltage electrical distribution systems including distribution transformers and switchgear, and electrical utilization services; interior and exterior mechanical and electrical renovations; and bringing buildings up to code compliance. Projects will also require the ability to design repair and replacement of various size boilers, controls and all associated equipment. Projects may also require the ability to convert coal fired and oil fired boilers into natural gas fired boilers and provide computational fluid dynamic modeling. The contract scope may require air permit modifications and submission to regulatory agencies. The contract scope may require evaluation and definition of asbestos materials, lead paint containing materials and toxic waste disposition and/or pollution control work as related to each project. The firm must demonstrate qualifications (with respect to the evaluation factors stated herein) to perform design of the projects listed above. Firms must be prepared to accept the aforementioned as a part of their contract responsibility. Three contract awards will be made from this synopsis; N40085-06-D-4412, N40085-06-D-4413 and N40085-06-D-4414. The contract will be of the Firm Fixed Price - Indefinite Quantity type. The duration of the contract will be for one (1) year from the date of the initial contract award. The proposed contract includes four (4) one year Government options for the same basic professional skills. The total A&E fee that may be paid under this contract will not exceed $4,000,000.00. The minimum guarantee for the entire contract term (including option years) will be satisfied by the award of the initial Task Order. The options may be exercised within the time frame specified in the resultant contract at the sole discretion of the Government subject to workload and/or satisfaction of the A&E performance under the subject contract. There will be no dollar limit per task order and no dollar limit per year. No other general notification to firms for other similar projects performed under this contract will be made. The A-E must demonstrate his and each key consultant's qualifications with respect to the published evaluation factors for design and all option services. Evaluation factors (1) through (6) are of equal importance; factors (7) and (8) are of lesser importance than factors (1) through (6). Specific evaluation factors include: (1) Professional qualifications of firm and staff proposed demonstrating the ability to design the repair and replacement of various size boilers, controls and all associated equipment and design the demolition, repair, replacement, extension and modification of steam and condensate lines, HVAC systems, plumbing, piping, motors, controls, electrical systems, fire protection systems including fire suppression and reporting systems, medium voltage electrical distribution systems including distribution transformers and switchgear, and electrical utilization services; interior and exterior mechanical and electrical renovations; and bring buildings up to code. Projects will also require the ability to design the repair and replacement of various size boilers, controls and all associated equipment. Project will also require the ability to convert coal fired and oil fired boilers into natural gas fired boilers and provide computational fluid dynamic modeling. The contract scope will also require air permit modifications and submission to regulatory agencies. The contract scope may require evaluation and definition of asbestos materials, lead paint containing materials and toxic waste disposition and/or pollution control work as related to each project. Firms will be evaluated in terms of the design staff's following qualifications: (a) active professional registration in the state in which the design services will be performed; and (b) experience (with present and other firms) and roles of staff members, specifically on the projects listed in the SF330. Each project should clearly indicate the personnel involved and those personnel should be listed by each project. (2) Specialized recent experience demonstrating the technical competence of particular staff members to design the projects addressed in evaluation factor number one. Each project listed should indicate key staff members involved. Firms will also be evaluated upon: (a) specific knowledge of the construction materials and practices of Eastern North Carolina; and the Federal and State of North Carolina laws, regulations, codes, and permits applicable to projects of this nature; (b) project experience as listed in the SF330 (provide design schedule, estimate vs. bid amount, and design team for each). (3) Capacity of the proposed design team to accomplish the following schedules: Submission of proposal 15 days following RFP. Final design submittal within 120 days of contract award. Project design schedules should be given for the same projects listed above for evaluation factors 1 and 2. (4) Past performance on the same projects listed above with Government agencies and private industry in terms of the following: (a) cost control techniques employed by the firm as demonstrated by the ability to establish an accurate project construction budget and design to this budget as evidenced by the low bid amount; (b) quality of work as demonstrated by the history of design related change orders issued during construction; (c) demonstrated long term business relationships and repeat business with Government and private customers; and (d) demonstrated compliance with performance schedules. Project information for this evaluation factor should be for the same projects listed above for evaluation factors 1 and 2. (5) Specific internal quality control procedures proposed for projects of this nature. Firm will be evaluated on the acceptability of their internal quality control program used to ensure technical accuracy and discipline coordination of plans and specifications. (6) Knowledge in prescribing the use of recovered materials and achieving waste reduction and energy efficiency in facility design. (7) Location in the general geographical area of the project. (8) The volume of work previously awarded to the firm by the Department of Defense shall also be considered, with the object of effecting an equitable distribution of Department of Defense architect-engineer firms, including small and small disadvantaged business firms, and firms that have not had Department of Defense contracts. All contractors are advised that registration in the DOD Central Contractor Registration (CCR) Database is required prior to award of a contract. Failure to register in the DOD CCR Database may render your firm ineligible for award. For more information, check the DOD CCR Website: http://www.ccr.gov. Architect-Engineer (A-E) firms which meet the requirements described in this announcement are invited to submit complete, updated Standard Form 330, Architect-Engineer Qualifications to the office shown above. If the SF 254/SF 255 is submitted for this solicitation, it will not be reviewed or considered. The SF 330 should be typed and one sided. As an attachment, provide an organization chart of the proposed team showing the names and roles of all key personnel listed in Section E with the associated firm as listed in Section C. Please include your DUNS, CAGE, and TIN numbers in Block 30 of the SF 330. Provide evidence that your firm is permitted by law to practice the professions of architecture or engineering, i.e., State registration number. These proposed contracts are being solicited on an unrestricted basis. In the event a large business is short-listed, the firm will be required to submit a subcontracting plan for approval before contract award. The small business size standard classification is NAICS 541330 ($4,500,000.00). Those firms that submit Standard Form 330 will only have to submit one copy to be considered for all three contracts. Clearly show the office location where work will be done and the experience of those that will do the work and their locations. The closing date for this announcement is April 11, 2006. Firms must submit forms to this office by 4:00 p.m. EST on the closing date. Late responses will be handled in accordance with FAR 52.215-1. Electronic (Email, facsimile, etc.) submissions are not authorized. The successful Offerors must have the capability of receiving and submitting all documents in an electronic format. Also, successful Offerors must have Internet access for browsing and receipt of electronic documents via Email. Submitted electronic documents must be in PDF (Portable Document Format). This is not a request for proposal, and there is no solicitation document or package or plans and specifications to be issued as a result of this announcement or a planholders/bidders list.
 
Place of Performance
Address: Department of the Navy, Naval Facilities Engineering Command, NAVFAC Atlantic, ROICC Camp Lejeune, Department of the Navy, Naval Facilities Engineering Command, Mid-Atlantic 1005 Michael Road, Camp Lejeune, NC, 28547-2521
Zip Code: 28547
Country: USA
 
Record
SN01004438-W 20060312/060310212803 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |