SOLICITATION NOTICE

39 -- Contractor shall furnish and deliver one (2) new draft tube man-rider air winch, Ingersoll-Rand model FA2i-Mr/05126 Force 5i Man-Rider Air Winch or equal,

Notice Date
2/28/2006
 
Notice Type
Solicitation Notice
 
NAICS
333923 — Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
 
Contracting Office
US Army Engineer District, Walla Walla, 201 N. Third Avenue, Walla Walla, WA 99362-1876
 
ZIP Code
99362-1876
 
Solicitation Number
W912EF-06-Q-0053
 
Response Due
3/10/2006
 
Archive Date
5/9/2006
 
Small Business Set-Aside
Total Small Business
 
Description
For PDF version of Solicitation Email: James.t.patchin@nww01.usace.army.mil Solicitation Number: W912EF-06-Q-0053 Posted Date: 2/28/2006 Response Date: 3/10/2006 Set-Aside: Total Small Business Contracting Office Address: U.S. Army Corps of Engineers, J. Todd Patchin, 509.527.7205, 201 North Third Street, Walla Walla Wa. 99362 Description: This is a combined synopsis/solicitation (# W912EF-06-Q-0053) for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the o nly solicitation. Quotes are being requested and a written solicitation will not be issued. This solicitation document and incorporated provisions and clauses are those in effect throughout Federal Acquisition Circular 05-03. This combined synopsis/solicit ation is set-aside 100% for small business. Governments decision will be based on best value. ALL LINE ITEMS MUST INCLUDE ALL CHARGES INCLUDING FOB DESTINATION SHIPPING. NAICS CODE 333923/423830 Sic 3531 BRAND NAME OR APPROVED EQUAL Man-Rider Winch BID ITEM LIST ITEM DESCRIPTION QUANTITY Price EA Total 01draft tube man-rider 2 $EA $____________ Air winch, Ingersoll-Rand Model FA2i-Mr/05126 Force 5i Man-Rider Air Winch or equal Total Price $__________ _________________________________________________________________________ BUSINESS SIZE___________________________-TAX ID #____________________________ DUNS #__________________________________-CAGE CODE #_________________________ BUSINESS NAME___________________________-BUSINESS POC________________________ BUSINESS ADDRESS________________________-BUSINESS PHONE______________________ BUSINESS E-MAIL_____________________________________________________________????_ SIGNED: _____________________________________________________________________ DATED: ????????______________________________________________________________________ Quotes must be in NLT 10:00 a.m. PST, March 10, 2006 or they will be considered late. BID SPECIFICATIONS FOR DRAFT TUBE MAN-RIDER AIR WINCH AT ICE HARBOR DAM SCOPE Contractor shall furnish and deliver one (2) new draft tube man-rider air winch, Ingersoll-Rand model FA2i-Mr/05126 Force 5i Man-Rider Air Winch or equal, to Ice Harbor Dam. Government personnel will install the new man-rider air winch. The contractor sh all also provide three (6) Operation and Maintenance Manuals describing the setup, parts, operation and annual maintenance for the draft tube man-rider air winch. The new draft tube man-rider air winch shall be warranted for materials and labor for a peri od of no less than one year. RATED CAPACITY The rated capacity for the new draft tube man-rider air winch shall be 3186 lbs for the top layer at an 8:1 man-rider safety factor. The rated capacity for the new draft tube man-rider air winch shall be 4400 lbs at a 5:1 safety factor for utility rating. LINE SPEED The new draft tube man-rider air winch shall have a line speed factory set at 75 fpm. The line speed of the new draft tube man-rider air winch shall have the ability to be reduced to 52 fpm at personnel rated loads and 55 fpm at utility rated loads. MOTORS The motor for the new draft tube man-rider winch shall be a radial piston. DRUM LENGTH The drum length for the new draft tube man-rider air winch shall be 8-inches. WIRE ROPE CAPACITY The new draft tube man-rider air winch shall have a wire rope capacity of 454-feet of 1/2 IWRC wire rope. The drum shall be grooved for 1/2 diameter wire rope. BRAKES The new draft tube man-rider air winch shall come with the following three (3) brakes: an automatic disc brake, an automatic drum brake and a manual drum brake. OPERATING PRESSURE The new draft tube man-rider air winch shall operate at 90psi and 335 cfm at the motor inlet. TESTING The new draft tube man-r ider air winch shall be tested in accordance with the attached testing certificate. LIMIT SWITCHES The new draft tube man-rider air winch shall come with an upper and lower rotary limit switches. PAINT The paint for the new draft tube man-rider air winch shall be a marine 812 top coat over sand blast and carbozinc. PILOT THROTTLE LEVER The throttle lever for the new draft tube man-rider air winch shall be remote on 6-feet of line. SCHEDULE Delivery shall commence no later than 60 days after award of contract. Contractor shall make prior arrangements with the Government Personnel at site to deliver and unload the equipment Normal working hours at Ice Harbor Dam is 6:30 a.m. to 5:00 p.m., Monday through Thursday. The draft tube man-rider air winch shall arrive between 7:00 a.m. and 2:00 p.m. during normal working days. This is to allow for unloading and inspection. The delive ry shall be made to the south side of the dam. The delivery address is as follows: Ice Harbor Dam 2763 Monument Drive Burbank, Washington 99323 Representations and Certifications - Commercial Items. FAR 52.212-4, Contract Terms and Conditions - Commercial Items, applies to this acquisition. The following FAR and DFARS clauses and provisions shall apply to this acquisition: 52.252-2, 52.211-6, 52.2 04-7, 52.232-33, 252.225-7000, 252.204-7004 Alternate A, 252.243-7001, 52.204-3, 52.219-1, 213-4. The Far Clause 52.214-21 Descriptive Literature shall apply to this acquisition: 52.222-3, 52.222-19, 52.222-21, 52.222-26, 52.219-6. The DFARS clause 252.212 -7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions, of Commercial Items (JAN 2005) paragraph (b), shall apply to this acquisition: 252.225-7001, 252.232-7003. As per 52.252-2, the full text of a FAR and DFAR clauses may be accessed electronically at http://farsite.hill.af.mil. CCR Requirement - Company must be registered on Central Contractor Registration (CCR) before an award will be made. If company is not registered in CCR, they may do so by going to CCR web site at http://www.ccr.gov. Submit quotes to--Todd Patchin--509.527.7205--509.527.7802 Fax--james.t.patchin@nww01.usace.army.mil
 
Place of Performance
Address: US Army Engineer District, Walla Walla 201 N. Third Avenue, Walla Walla WA
Zip Code: 99362-1876
Country: US
 
Record
SN00996284-W 20060302/060228213502 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.