Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 23, 2006 FBO #1550
SOLICITATION NOTICE

66 -- Gas Analyzers

Notice Date
2/21/2006
 
Notice Type
Solicitation Notice
 
NAICS
334513 — Instruments and Related Products Manufacturing for Measuring, Displaying, and Controlling Industrial Process Variables
 
Contracting Office
Department of Justice, Bureau of Alcohol, Tobacco and Firearms (ATF), Acquisition and Property Management Division, 650 Massachusetts Avenue, N.W., Room 3290, Washington, DC, 20226
 
ZIP Code
20226
 
Solicitation Number
630100000024SQ
 
Response Due
2/27/2006
 
Archive Date
3/14/2006
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined solicitation synopsis. No other solicitation is available. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This requirement is a 100% small business set-aside. However, if the government does not receive responses from small businesses, other businesses will be considered. The Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF) requires, on a firm fixed-price basis, the following: Specifications are for four oxygen (02), carbon dioxide (C02) and carbon monoxide (CO) analyzers for gas species analysis during fires. These analyzers can be in a combined unit or separate units as long as the technical specifications provided below are met: Both Analyzers must be equipped with power: 120 VAC, 60 Hz Analog Output: 4 ? 20 mA Configuration: 19? rack mountable Connections: ?? tubing. ITEM 0001: Oxygen (O2) Analyzer Type: Paramagnetic Range: overall 0-22%, adjustable to a range of 15 ? 22%, 5% minimum measuring span Sample flow rate: 0.3 ? 1.01pm Response Time (t90): less than 4 seconds Pressure affects: less than 0.2% of range per 1% change in absolute pressure Linearity Error: less than 1% of full scale/span Repeatability: less than 1% of full scale/span Zero Drift: less than 0.5% of smallest range per month Measurement Drift: less than 0.5% of span per month Output resolution: 0.01% absolute or better (2 decimal place accuracy). ITEM 0002: Carbon Monoxide (CO2) and Carbon Monoxide (CO) Analyzer Type: NDIR Range: Adjustable 0 ?5% and 0 ? 25% Pressure affects: less than 0.2% of span per 1% change in absolute pressure Linearity Error: less than 1% of full scale Repeatability: less than 1% of smallest range Drift: less than 2.0% of smallest range per week Output resolution: 0.1% of span. Shipping must be FOB Destination to Beltsville, MD 20705. The following provisions are applicable to this commercial item acquisition: FAR 52.212-1, Instructions to Offerors-Commercial; FAR 52.212-3, Offeror Representations/ (Vendors must furnish Offeror Representations in writing); FAR 52.212-4, Contract Terms and Conditions-Commercial items; and FAR 52.212-5, Contract Terms and Conditions Required to Implement Status or Executive Orders- Commercial Items, and Justice Acquisitions Regulation 2852.211. Award will be made to the responsive, responsible vendor meeting all the requirements above at the lowest price on an All None Basis. Submit quotes to ATF 650 Massachusetts Avenue, Attn: Paula King Room 3290, Washington, DC 20226, and No Later Than February 27, 2006, 2:00 pm EST. Alternatively, vendors may fax quotes and questions concerning this procurement to Paula King, 202/927-8688 or Brian Wilkins or e-mail to Paula.King@atf.gov or Brian.Wilkins@atf.gov. Vendor must have registered in the Central Contractor Registration Database at www.ccr.gov to receive this award.
 
Place of Performance
Address: 6000 Ammendale Rd, Beltsville, MD
 
Record
SN00991607-W 20060223/060221211731 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.