Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 02, 2006 FBO #1529
SOLICITATION NOTICE

Y -- DESIGN, FABRICATE AND ERECT POTABLE AND FIRE WATER SYSTEMS

Notice Date
1/31/2006
 
Notice Type
Solicitation Notice
 
NAICS
541330 — Engineering Services
 
Contracting Office
Department of Energy, Bechtel SAIC Company, LLC (DOE Contractor), Yucca Mountain Project, 1180 Town Center Drive, Las Vegas, NV, 89114
 
ZIP Code
89114
 
Solicitation Number
ENG-06-001
 
Response Due
2/10/2006
 
Archive Date
2/25/2006
 
Description
Bechtel SAIC Company, LLC (BSC) is soliciting expressions of interest and requesting information on design and installing of a Potable Water System and a Fire Water System. The two (2) systems will supply both potable water and fire water to four (4) one-story buildings that are expected to have a total occupancy of approximately 700 personnel. Attached are conceptual drawings of the potable water supply distribution system and the fire water system. The following information is preliminary and is not guaranteed to represent the final design. - Raw water will be supplied from an existing 8" PVC line. The water pressure will be approximately 60 psi and the flow rate approximately 260 gpm at the tie-in point. The raw water chemistry is contained in the attached analysis. All below ground piping is suggested to be PVC. - The Potable Water System will be fed from the existing raw water main, shall be required to be treated, and shall be stored prior to distribution. Potable water shall be treated to remove arsenic to the current EPA requirements and shall be chlorinated. After treatment, the potable water shall be stored in a steel potable water tank with an approximate capacity of 170,000 gallons. The potable water distribution system shall supply potable water at a peak flow rate of 350 gpm and an average flow rate of 110 gpm. The minimum required potable water pressure into each of the four buildings is 65-75 psi. The potable water system shall meet the requirements of Nevada Division of Environmental Protection, Administrative Code, NAC 445A, Water Controls. Potable water piping shall terminate approximately ten (10) feet from the site boundary of the Potable Water System location. A predetermined termination point for future tie-in to the Potable Water System will be identified. Connection to tie-in will be performed by others. - The Fire Water System will be fed from the existing raw water main and required to be stored prior to being pressurized through the fire water loop. The fire water shall be stored in a steel fire water tank with an approximate capacity of 300,000 gallons and then pressurized via a 150 hp diesel fire water pump with associated jockey pump prior to entry to the four buildings. The fire water piping shall terminate approximately ten (10) feet from the site boundary of the Fire Water System location. A predetermined termination point for future tie-in to the Fire Water System will be identified. Connection to tie-in will be performed by others. Provide your interest in receiving a Request for Proposal (RFP) for the design and installation of the two above described systems consisting site preparation, two steel field erected tanks, a 150 hp diesel fire water pump with associated jockey pump, potable water treatment and repressurization system, enclosures for both systems, and all interconnecting piping with freeze protection. Respondent is requested to provide the following information: 1) Estimated procurement lead times from time of award to delivery at the jobsite of each major piece of equipment and materials required for field erection. 2) Estimated construction time for the field erected tanks, enclosures, piping, etc.. 3) Recommendations for design optimization, design alternatives or other suggested recommendations. Regards, Larry G. Bannister ATTACHMENTS: (documents can be found in the complete solicitation posted on the Internet at http://bscupdate.com/supplier_subcontractor/activerfi.pdf 1. Water Chemistry 2. Potable Water P&ID 3. Fire Water P&ID RESPONSE SUBMITTAL: This is not a solicitation for Proposal and providing the requested information will not guarantee an award of Contract. All questions concerning this RFI may be faxed to (702) 295-0019. Responses are to be sent via E-mail to: Larry_Bannister@ymp.gov on/or before February 10, 2006. Respondent must include the name, title, address, telephone number, facsimile telephone number, and email address of the responsible person to whom future communications regarding the RFI should be addressed. Bechtel SAIC Company, LLC 1180 Town Center Drive Las Vegas, Nevada 89144 Attention: Project Procurement Department
 
Place of Performance
Address: Subcontractor's office and job site
Country: United States
 
Record
SN00977224-W 20060202/060131213815 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.