Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 04, 2005 FBO #1439
SOLICITATION NOTICE

J -- Ultrasonic Side Scan for USCGC Monhegan (WPB-1305)

Notice Date
11/2/2005
 
Notice Type
Solicitation Notice
 
NAICS
336611 — Ship Building and Repairing
 
Contracting Office
DHS - Direct Reports, United States Coast Guard (USCG), Commanding Officer (vpl), USCG Maintenance and Logistics Command - Atlantic, 300 East Main Street Suite 600, Norfolk, VA, 23510-9102
 
ZIP Code
23510-9102
 
Solicitation Number
HSCG80-006-Q-3FA392
 
Response Due
11/15/2005
 
Archive Date
11/2/2006
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. Solicitation HSCG80-06-Q-3FA392 is being issued as a Request for Quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 05-06. The NAICS code is 336611 with a small business size standard of 1000 employees. This is a small business set-aside. Commercial contractor to conduct Scanning Crawler Automated Test for ship hull corrosion inspection onboard USCGC Monhegan (WPB-1305)that is to be dry-docked at Savannah, GA. The REQUIREMENT is as follows: (a) Provide a crew to operate all side scan equipment (b) Provide an ASNT Level III Analyst. The level III must be on site. (c) Must complete the scan within 10 calendar days starting on or about November 28 to December 2, 2005.(d) Provide a daily update to MLCLANT or designated representative on all areas inspected and potential issues or schedule changes. This daily report must identify all bad metal areas found (e) Hand held UT reading must be taken to verify bad metal areas found with the side scan equipment. All readings must be provided to the CG representative and the lowest reading must be marked on the hull at the bad metal location. (f) Any Scanning Parameter or Scope of work changes must be signed off by the designated onsite representative. SCANNING PARAMETERS: The following Parameters will be used during the course of this inspection: (a) Scanning resolution will be set to (.5x .5). (b) Scan data indicating wastage greater than or equal to 15% nominal plate thickness will be highlighted in RED and designated a repair area. (c) Scan data indicating wastage greater than or equal to 10% to 14% of nominal plate thickness will be highlighted in YELLOW. (d) Scan data indicating wastage less than 10% of nominal plate thickness will be highlighted in GREEN. (e) The inspection area is defined as the Port, Starboard, and Transom exterior shell plate below the water line but shall EXCLUDE: Areas under and within 6-inches of blocks and side blocks. (Areas that are accessible, 6 inches from blocks and side blocks, must be hand scanned. Up to 6-inches around any obstacle on the hull including sea suctions, discharges, rudderposts, knuckle, bow stem, stabilizer tubes, and stern tubes. Inverted curve area below the Spray Rail. Bow section forward of plates P-P, R-R, and U-U. Any areas blocked by immovable scaffolding or shipyard activity. Stainless Steel Inserts. Areas that are accessible but cannot be scanned by scanning equipment will be hand-scanned. Any Repair areas found during the hand scan will be marked on the ships hull and their approximate positions will be recorded on the plate drawings and report summary. USCG SUPPLIED ITEMS: (a) Shell Plate Expansion drawing that provides plate numbers. thickness, and location on hull. (b) Two circuits of 15 amps 120 volts single phase within 50 ft of vessel. (c) .5GPM of fresh water within 50 ft of vessel with hose adapter fitting. (d) Approved scaffolding or man lift to bring inspection personnel within 1ft of all inspection areas that are 5ft above ground level. (e) Surface prep shell plate with an ultra high-pressure water spray or grit blast to bare metal and primer skim coat (3 to 5 mil) to prevent flash rust. REPORTS: Provide final report within 7 working days after the inspection is completed. (a) A copy of all repair areas must be summarized and submitted to the CG representative prior to departing job site. Final report will be required within 7 working days after the side scan is completed. (b) All areas failing the Scanning criteria (RED data) will be designated as repair areas and these areas will clearly marked on the hull with white or yellow marking paint. (c) Two hard copies of the report with two CD?s containing the electronic (raw) data. Reports shall include: Inspection overview: 1-2 data sheets per plate depending on plate size Mosaic of scanned data overlain on the Shell Plate Expansion Drawing Digital photos of all designated repair areas. All designated repair areas be blocked in a blue outline on the data sheets. CD?s will contain a complete copy of the report, interactive data files, and digital pictures. All electronic files are compatible with standard UCSG workstation operating software. Electronic files format must be such that the CG has the capability to change the percent of wastage (format conditioning) per plate. Electronic files may be opened using MS Word, Ms Excel, PDF software. Digital picture are recorded in JPEG format. Quotes are due on or before November 15, 2005 1600 EST via email at bgarner@mlca.uscg.mil or by fax to (757) 628-4676. Questions or requests for additional information may be referred to Beverly Garner via email, phone 757-628-4663, or at U.S. Coast Guard, MLCA, vpl-2, 300 East Main Street, Suite 600, Norfolk, VA 23510-9102.
 
Place of Performance
Address: 301 North Lathrop Avenue, Savannah, GA
Zip Code: 31415
Country: US
 
Record
SN00924831-W 20051104/051102211537 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.