Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 09, 2005 FBO #1383
MODIFICATION

54 -- Dust Control Booth

Notice Date
9/7/2005
 
Notice Type
Modification
 
NAICS
333411 — Air Purification Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Special Operations Command, 16th CON - Hurlburt, 350 Tully Street, Hurlburt Field, FL, 32544-5810
 
ZIP Code
32544-5810
 
Solicitation Number
F2F2105230A200
 
Response Due
9/9/2005
 
Archive Date
9/24/2005
 
Point of Contact
James Summers, Contract Specialist, Phone (850)884-7794, Fax (850)884-5372, - Gloria Dulin, Contracting Officer, Phone 850 884-3262, Fax 850 884-5372,
 
E-Mail Address
james.summers@hurlburt.af.mil, Gloria.Dulin@hurlburt.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
Answers to questions: Typically, the air velocity inside a booth is 100 to 160 FPM. Based on some simple engineering calculations, the cross section of the booth is 24ft wide by 12ft high which equals a cross section area of 288 sq ft. The booth spec is rated at 24,000 CFM, however 24,000 CFM at 288 sq ft would only equal 83.3 FPM inside the booth. In order to achieve 400 FPM, you would need to take to 288 sq ft and multiply it by 400 which equals 115,200 cfm or 230,400 CFM for 800 FPM. My question is what FPM inside the booth are you looking for? ANSWER: Per Bio we have to have a minimum of 100 FPM inside the booth so we need whatever is req'd to make that happen. Do we need to provide electrical contracting services to connect the electrical control panel that will operate the booth to the existing 460V power or will electrical services be provided by others ANSWER: Yes we are going to need contracting services to connect the electrical control panel. Do we need to provide an air compressor for filter cleaning operation, or is compressed air available at the job site? If air line is available, how close to booth location? We will need 1" air line rated for 90-100 PSIG. ANSWER: There's already an airline in the area where the booth is going to go. Do we need to install fire sprinklers inside the booth? ANSWER: Yes we are going to need fire sprinklers in the booth. There is already a line in the room for them to tie into for the sprinklers though.
 
Place of Performance
Address: 16th EMS, 406 Tully Street, Hurlburt Field FL
Zip Code: 32544
Country: USA
 
Record
SN00889134-W 20050909/050908033657 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.