Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 27, 2005 FBO #1370
MODIFICATION

66 -- Incubator (growth chamber)

Notice Date
8/25/2005
 
Notice Type
Modification
 
NAICS
339111 — Laboratory Apparatus and Furniture Manufacturing
 
Contracting Office
Department of Agriculture, Agricultural Research Service, Pacific West Area Office, 800 Buchanan Street, Albany, CA, 94710-1105
 
ZIP Code
94710-1105
 
Solicitation Number
5-5350-5-16
 
Response Due
8/25/2005
 
Archive Date
9/9/2005
 
Point of Contact
Carole Kneedler, Program Coordinator, Phone 509-664-2280, Fax 509-664-2287, - Carole Kneedler, Program Coordinator, Phone 509-664-2280, Fax 509-664-2287,
 
E-Mail Address
kneedler@tfrl.ars.usda.gov, kneedler@tfrl.ars.usda.gov
 
Description
Incubator with following requirements: Interior: 29 cubic ft; Interior: Stainless steel, 20 gauge or thicker; Shelves: 6 or more, 20 gauge stainless, adjustable heights; Construction: double wall; Insulation: foamed-in-place urethane, > or = 2 inch thick; Door with lighting: Triple thermo pane glass door containing 4 F40T12CW/HO fluorescent lamps, ballasts and tube axial fans for cooling of housing. Light output of approx. 17,200 lumens; Light controller: Adjustable 24 hr timer; Feet/Casters: 2 inch dia dual wheel, swivel type; Air flow: Horizontal, right to left or left to right, thru perforated duct sheets; Heaters: two 600 watt, 120 volt; Refrigeration: min. 1/4 hp, 115 volt, air cooled, hi-temp condensing unit, non-CFC R134A refrigerant, phenolic coated evaporator; Defrost: Hot gas with automatic timer; Temp. range: 0C to 60C, +/-0.5C uniformity in a 22C, 50% RH ambient; Humidity range at 0C: 50% to 95% RH, +/-5% control in a 22C, 50% RH ambient, calibrated at 12%; Humidity range at 60C: 9% to 80% RH, +/-5% control in a 22C, 50% RH ambient, calibrated at 12%; Electrical: 208-220VAC, 1 phase, 4 wire, 50HZ; Alarms: Over and under temp audible and visual; Safeties: Over and under temp thermostat; Humidity system: 1000 watt steam generator; Humidity controller: LED PID microprocessor programmable, 4 file/24 steps, auto-tuning, thin film sensor, 4 to 20 MA output, plus, regenerative heatless dryer to maintain 12% RH at 25C in a 22C and 50% RH ambient with no heavy moisture load. 2 each
 
Place of Performance
Address: 1104 N. WESTERN AVENUE, WENATCHEE, WA 98801,
Zip Code: 98801
Country: US
 
Record
SN00879121-W 20050827/050825211651 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.