48 -- 1. DELTECH REFRIGERATED AIR DRYER 2. DEL-MONOX AIR PURIFIER 3. DRAIN VALVE

Notice Date
8/18/2005
 
Notice Type
Solicitation Notice
 
Contracting Office
N00244 Naval Base 937 North Harbor Drive San Diego, CA
 
ZIP Code
00000
 
Solicitation Number
N0024405T0939
 
Response Due
8/22/2005
 
Archive Date
9/21/2005
 
Description
1. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes that a written solicitation will not be issued. PAPER COPY OF SOLICITATION NUMBER N00244-05-T-0939 IS AVAILABLE. It is the contractor's responsibility to be familiar with the applicable clauses and provisions. The clauses may be accessed in full text at these addresses: www.arnet.gov.far and www.dtic.mil.dfars. The RFQ and incorporated provisions and clauses are those in effect through FAC 2001-14 and class deviation 2002-00003. This solicitation is issued as RESTRICTED (100% Small business set-aside). NAICS Code 332911 and business size standard of 500 employees is applicable. The Fleet and Industrial Supply Center-San Diego (FISCSD N00244) is announcing a requirement for the following: Line Item 0001 NONCYCLING REFRIGERATED AIR DRYER FFP - DELTECH PYRAMID SERIES. PART NUMBER PYR1000. *4" 150# ANSI FLANGED CONNECTIONS. *MAXIMUM OPERATING PRESSURE 232 PSIG. *460 VOLT / 3 - PHASE / 60 HZ *DEW POINT +33*F TO +39*F CAPACITY 1000 SCFM @ 100 PSIG AIR INLET PRESSURE @ 100 * F AIR INLET TEMPERATURE @ 100% RELATIVE HUMIDITY @ 100*F AMBIENT AIR TEMPERATURE. *ENERGY SAVING 2-MODE OPERATION: MANUAL ON/OFF AND SCHEDULED ON/OFF > In schedule mode the dryer automatically turns on-And-off according to your schedule. *SERVICE REMINDER MONITOR REMINDS YOU WHEN SERVICE IS REQUIRED BASED ON YOUR NEEDS. *DRYER OPERATION MON! ITOR ALLERTS OPERATOR IF A FAULT CONDITION OCCURS, AND IDENTIFIES WHAT IS WRONG. *CONTROL PANEL FEATURES INCLUDE: >Manual on / off, Schedule on / off, and Drain Push-To-Test Buttons >Power - On And Compressor - On Lights >Operator Alert Light - Indicates that service is required or there is a refrigeration system or drain fault >Dew Point Temperature Indicator >Operator Interface with readouts for current time, operating status, time - to - service, and total operating hours >Information is available in five languages. >"No" & "NC" Alarm contacts; RS - 232 Connection allows remote ! monitoring of dryer operating status, Settings and Active Faults. >Control system is Volt and is Third Party Certified as not causing or being affected by Electromagnetic Interference Line Item 0002 DEL-MONOX BREATHING AIR PURIFIER FFP - PART NUMBER: 5913 >1-1/2" NPT INLET & 1-1/4" OUTLET CONNECTIONS. >MODEL 150 COALESCING PREFILTER. >MODEL C20 FINAL FILTER. >104 SCFM OUTLET AIR FLOW - 100 PSIG AIR INLETPRESSURE AND 100 DEGREE F AIR INLET TEMPERATURE. Line Item 0003 DRAIN VALVE FFP - PART NUMBER:ADV-1711. >1/4" NPT, 115V, CAT. #3065227 FAR Clause 52.211-5 Brand Name or Equal is applicable to this solicitation. DELIVERY LOCATION: NAVAIRSEAFAC, NAS NORTH ISLAND, BLDG.801,San Diego, CA 92135. THERE IS NO GOVERNMENT-FURNISHED MATERIAL (GFM). The delivery date is (10) days After Receipt Of Order or sooner. All material will be inspected and accepted at DESTINATION. Contractors are required to provide descriptive technical literature per FAR 52.212-1(b)(4). IMPORTANT NOTICE: DFARS 252.204-7004 ?Central Contractor Registration? (CCR) is required and applies to all solicitations issued on/after 6-1-98. Lack of registration in the CCR database will make an offeror/quoter ineligible for award of a contract/purchase order. Please ensure compliance with this regulation when submitting your quote. Utilize the CCR website at http://www.ccr.gov and/or call the CCR Assistance Center at 888-227-2423 for more information. THE FOLLOWING PROVISIONS AND CLAUSES ARE APPLICABLE AND ARE HEREBY INCORPORATED INTO THE SOLICITATION BY REFERENCE AND BY FULL TEXT. THE FULL TEXT OF THE CLAUSES/PROVISIONS FROM THE FAR AND DFARS CAN BE ACCESSED VIA THE INTERNET USING THE FOLLOWING WEB-SITE ADDRESS: www.arnet.gov or http://farsite.hill.af.mil FAR 52.213-4, Instructions to Offerors OTHER THAN Commercial Items NOTE: This provision must be reviewed completely. It contains the guidelines for submission of your quotation. Addendum to FAR 52.212-1, Instructions to Offerors - Commercial Items; 52.212-3 ALT I, OfferorRepresentations and Certifications - Commercial Items; 52.212-4, Contract Terms and Conditions - Commercial Items (List the clauses that apply; and 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items (list the clauses the apply). Quoters shall include and are reminded to include a completed copy of 52.212-3 ALT I with quotes. 252.212-7000,Offeror Representations and Certifications - Commercial Items and 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items including all clauses and provisions that may be applicable. End of Clauses/Provisions. Quotation information may be submitted electronically via e-mail or by fax. Submit quotations to: Fleet and Industrial Supply Center, Regional Contracts Dept., 937 N. Harbor Dr., Ste. 60, San Diego, CA 92132-0060 Attn: Constance Hayes, Contract Specialist, Code 240. Phone Number (619) 532-1123 Fax Number (619) 532-1088 E-mail: constance.hayes@navy.mil Reference solicitation number: N00244-05-T-0939 on all documents and requests for information. Quotes must be received no later than COB 22 AUGUST 2005 4:00 p.m. 52.212-2, Evaluation - Commercial Items is applicable to this procurement. While price will be a significant factor in the evaluation of offers, the final contract award will be based on a combination of factors - a combination of price and delivery; determination of responsibility; technically acceptable low bid and past performance. Addenda to FAR 52.212-1 is DFAR 252.204-7004 entitled "Required Central Contractor Registration (CCR). Quoters must be registered in the CCR Database to be considered for award. Registration is free and can be completed on-line at https://www.ccr.dlis.dla.mil/ccr/scripts/index.html All quotes shall include price(s), FOB Point, a point of contact, name and phone number, GSA contract number if applicable, business ! size, Cage code, and payment terms. Parties responding to this solicitation may submit their quote in accordance with their standard commercial practices (e.g. on company letterhead, formal quote form, etc.) but must include the following information: 1) Company's complete mailing and remittance addresses, discounts for prompt payment, if any (e.g. 1% 10 days), anticipated delivery; availability of product or period of performance for service; Company Cage Code, Dun and Bradstreet Number, and Taxpayer ID Number. In addition, if you are quoting on a comparable commercial item, product literature must be included. All FAR certifications and representations specified above must also accompany your quote. Quotes submitted as an attachment to an e-mail must be sent in Word Version 6.0 or higher. !
 
Web Link
click here to link to the FISC-SD website.
(http://www.sd.fisc.navy.mil)
 
Record
SN00874132-W 20050820/050818213344 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.