Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 25, 2005 FBO #1307
MODIFICATION

35 -- FILTER BLOWER SYSTEM

Notice Date
6/23/2005
 
Notice Type
Modification
 
NAICS
333411 — Air Purification Equipment Manufacturing
 
Contracting Office
ACA, Dugway Proving Ground, Division of Contracting, Building 5330 Valdez Circle, Dugway, UT 84022-5000
 
ZIP Code
84022-5000
 
Solicitation Number
W911S6-05-T-0048
 
Response Due
6/29/2005
 
Archive Date
8/28/2005
 
Small Business Set-Aside
N/A
 
Description
AMENDMENT 0003 - The purpose of Amendment 0003 is to change the solicitation from sole source to full and open competition, extend the proposal due date and further clarify the combined synopsis. The following changes are incorporated in Amendment 0 003: (1) This solicitation is amended to reflect full and open competition vice sole source. (2) The proposal due date is extended to Wednesday, 29 June 2005 at 6:00 PM EST (4:00 PM Local). (3) The following responses to questions regarding the combined synopsis are provided: Q: Should the fans and VFDs be rated as specified (expecting a later change order)? Or should the spec be amended to reflect the properly sized blower and VFD set? A. The static pressure rating for the fan is inadequate for proper system operation, therefore the fan specification should be ammended to read 2000 CFM @ 6 Inch SP. Q: Can the Offeror assume that CWA are limited those that are readily adsorbed by non-impregnated activated carbon? And is the qualification for the adsorber still per IEST-RP-CC-008 (i.e. 3-log reduction against a Freon challenge)? A. The CWA encountered within this system is readily adsorbed by non-impregnated activated carbon. The qualification for the adsorber is IEST-RP-CC-008, three-log reduction against Freon challenge. Q: Should the fans and VFDs be rated as specified (expecting a later change order)? Or should the spec be amended to reflect the properly sized blower and VFD set? A. Amended to 2000 CFM @ 6 Inch static pressure. Q: Can the Offeror assume that CWA are limited those that are readily adsorbed by non-impregnated activated carbon? And is the qualification for the adsorber still per IEST-RP-CC-008 (i.e. 3-log reduction against a Freon challenge)? A. The CWA encountered within this system is readily adsorbed by non-impregnated activated carbon. The qualification for the adsorber is IEST-RP-CC-008, three-log reduction against Freon challenge. Q. If the operating voltage is 208 then why is the control transformer 460:120? A. The 460 volt reference is a typo, there is no requirement for 460 VAC service. Power supplied to the filter blower will be 208 VAC 3 phase, with control power step-down methods at the discretion of the vendor.
 
Place of Performance
Address: ACA, Dugway Proving Ground Division of Contracting, Building 5330 Valdez Circle Dugway UT
Zip Code: 84022-5000
Country: US
 
Record
SN00835352-W 20050625/050623220838 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.