J -- NAVAIR METCAL 5700AAN & 575725A Modules Exchange Program & Repair

Notice Date
6/6/2005
 
Notice Type
Solicitation Notice
 
NAICS
334515 — Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
 
Contracting Office
Department of the Navy, Naval Air Systems Command, Naval Air Warfare Center Aircraft Division Pax River, Building 441 21983 Bundy Road Unit 7, Patuxent River, MD, 20670
 
ZIP Code
20670
 
Solicitation Number
N00421-05-C-0111
 
Response Due
6/21/2005
 
Archive Date
7/6/2005
 
Description
The Laboratory Instruments and Standards Team (LIST) Code 492110A of the Research and Engineering Sciences Department Metrology Division of Naval Air Systems Command (NAVAIR), Patuxent River Maryland has been designated by the NAVAIR Metrology and Calibration (METCAL) Program to be the depot repair facility for the entire population of 5700AAN modules and 5725A modules in the METCAL Program inventory. LIST will ship modules directly to the repair facility. Modules returned are sometimes non-repairable because of physical damage to the 6 layer Printed Circuit Board (PCB). These modules will be replaced with new modules. Other modules sent will be repaired. Fluke Corporation has proprietary rights to the design of the 5700AAN and 5725A modules and the module Exchange Program Design. The Government intends to negotiate and establish a Sole Source Firm Fixed Price contract with Fluke Corporation, 6920 Seaway Blvd, Everett, WA 98203-5829 to perform the module repair and/or supply a new module to the Government. The total estimated dollar value of this procurement is estimated to be $185,762.50. THIS IS NOT A REQUEST FOR PROPOSAL. Interested parties should submit the following information describing their capabilities to Ms. Theresa Newton: a company pamphlet, brochure, or description of the company?s abilities/history with this type of service; a description of the equipment to be utilized including the methods of transporting modules; the name and telephone number of a company representative that can be contacted, and the company?s address. Once responses are received, interested parties may be requested to provide a presentation to further describe their capabilities. Written responses to this announcement can be submitted to: Ms. Theresa Newton NAVAIRSYSCOM NAVAIR Contracts 2.5.1.3.3.4 21983 Bundy Road Unit 7 Bldg 441 Patuxent River, MD 20670 theresa.newton@navy.mil ?THERE IS NO COMMITMENT BY THE GOVERNMENT TO ISSUE A SOLICITATION, MAKE AN AWARD OR BE RESPONSIBLE FOR ANY MONIES EXPENDED BY ANY INTERESTED PARTIES IN SUPPORT OF THE EFFORT MENTIONED ABOVE. INFORMATION PROVIDED HEREIN IS SUBJECT TO CHANGE AND IN NO WAY BINDS THE GOVERNMENT TO SOLICIT OR AWARD A CONTRACT?. STATEMENT OF WORK Item 0001 761346/A5 MODULE REPAIR Module repair or exchange services and new modules 761346 / A5 for S/N's 5465003, 5610014, 5455014, 5435016, 5485012 for the Depot Repair effort on 5700AAN multifunction calibrators QTY 5 Item 0002 775429/A14 MODULE REPAIR Module repair or exchange services and new modules 775429 / A14 for S/N's 5455014 for the Depot Repair effort on 5700AAN multifunction calibrators QTY1 Item 0003 761155 / A15 MODULE REPAIR Module repair or exchange services and new modules 761155 / A15 for S/N 5455014 for Depot Repair effort on 5700AAN multifunction calibrators QTY 1 Item 0004 761163 / A16 MODULE REPAIR Module repair or exchange services and new modules 761163 / A16 for S/N's 5610014, 5435016, 5465011, 5430016 for Depot Repair effort on 5700AAN multifunction calibrators QTY 4 Item 0005 761171 / A17 MODULE REPAIR Module repair or exchange services and new modules 761171 / A17 for S/N 5315012 for the Depot repair effort on 5700AAN multifunction calibrators QTY1 Item 0006 761189 / A18 MODULE REPAIR Module repair or exchange services and new modules 761189 / A18 for SN's 5610014, 5475019 for the Depot repair effort on 5700AAN multifunction calibrators QTY2 Item 0007 761098 / A6 MODULE REPAIR Module repair or exchange services and new modules 761098 / A6 for S/N 5485012 for Depot Repair effort on 5700AAN multifunction calibrators QTY1 Item 0008 764613 / A7 MODULE REPAIR Module repair or exchange services and new modules 764613 / A7 for S/N's 5465003, 5435017, 5610014, 5455014, 5435016, 5485012, 5315012, 5475019 for the Depot repair effort on 5700AAN multifunction calibrators QTY8 Item 0009 761106 / A8 MODULE REPAIR Module repair or exchange services and new modules 761106 / A8 for S/N's 5435017, 5610014, 5455014, 5435016, 5315012, 5475019 for the Depot repair effort on 5700AAN multifunction calibrators QTY6 Item 0010 761122 / A11 MODULE REPAIR Module repair or exchange services and new modules 761122 / A11 for S/N's 5435017, 5610014, 5455014, 5435016, 5465011, 5315012 for the Depot repair effort on 5700AAN multifunction calibrators QTY6 Item 0011 761130 / A12 MODULE REPAIR Module repair or exchange services and new modules 761130 / A12 for S/N's 5455014, 5435016, 5315012 for the Depot repair effort on 5700AAN multifunction calibrators QTY 3 Item 0012 761023 / A3 NEW MODULE New modules 761023 / A3 for S/N's 5435017, 5455014, 5315012, and 5530013 for the Depot repair effort on 5700AAN multifunction calibrators QTY7 ITEM 0013 760942 / A4 NEW MODULE New modules 760942 / A4 for S/N's 5435017, 5455014, and 5530013 for the Depot repair effort on 5700AAN multifunction calibrators QTY 3 Item 0014 761346 / A5 NEW MODULE New modules 761346 / A5 for S/N's 5465011, 5315012, 5475019 for the Depot repair effort on 5700AAN multifunction calibrators QTY6 Item 0015 761163 / A16 NEW MODULE New modules 761163 / A16 for S/N's 5475019, 5315012 for the Depot repair effort on 5700AAN multifunction calibrators QTY 2 Item 0016 868794 KNOB Part # 868794 for S/N's 5435017, 5610014, 5435016, and 5315012 for Depot repair on 5700AAN multifunction calibrators QTY 6 Item 0017 761049 / Keyboard (A1) (PART) QTY 1 Item 0018 761155 / High Voltage/High Current (A15) (NEW MODULE) QTY 2 Item 0019 761163 / Power Amplifier (A16) (NEW MODULE) QTY 3 Item 0020 761171 / Regulator/Guard Crossing (A17) (NEW MODULE) QTY 3 Item 0021 761189 / Filter/PA Supply (A18) (NEW MODULE) QTY 5 Item 0022 886366 / Binding Posts, Blue (PART) QTY 15 Item 0023 886374 / Binding Posts, Green (PART) QTY 15 Item 0024 831990 / 500 Milliamp Fuse (PART) QTY 30 Item 0025 843065 / Interconnect Board (A1) (NEW MODULE) QTY 1 Item 0026 843073 / Current Amplifier (A2) (NEW MODULE) QTY 2 Item 0027 843086 / High Voltage Amplifier (A3) (NEW MODULE) QTY 3 Item 0028 843078 / Power Supply (A4) (NEW MODULE) QTY 3 Item 0029 843081 / Digital (A5) (NEW MODULE) QTY 2 Item 0030 843060 / High Voltage Sense (A6) (NEW MODULE) QTY 2 Item 0031 860119 / Inductor (A30) (NEW MODULE) QTY 2 Item 0032 843029 / Fan Assembly (MP511) (PART) QTY 2 Item 0033 561506 / 8 Amp Fuse (F1) (PART) QTY 5 Item 0034 216846 / 4 Amp Fuse (F2) (PART) QTY 5 Item 0035 886341 / Handle (PART) QTY 20 Item 0036 886416 / Air Filter Housing (PART) QTY 2 Item 0037 761098 / Wideband Oscillator (A6) (NEW MODULE) QTY 2 Item 0038 764613 / Current / High-Resolution Oscillator (A7) (NEW MODULE) QTY 3 Item 0039 761106 / Switch Matrix (A8) (NEW MODULE) QTY 3 Item 0040 761122 / DAC (A11) (NEW MODULE) QTY 4 Item 0041 761130 / Oscillator Control (A12) (NEW MODULE) QTY 2 Item 0042 775429 / High Voltage Control (A14) (NEW MODULE) QTY 1 Item 0043 701979, Insulator Shaft (PART) QTY 10 Item 0044 217414, Rotary Function Switch (PART) QTY 1
 
Place of Performance
Address: Fluke Corporation, 6920 Seaway Blvd, Everett, WA
Zip Code: 98203-5829
Country: USA
 
Record
SN00823585-W 20050608/050606212307 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.