Z -- Remove and Replace Industrial Doors at Various Facilities, Lajes Field Azores

Notice Date
3/3/2005
 
Notice Type
Modification
 
NAICS
238290 — Other Building Equipment Contractors
 
Contracting Office
Department of the Air Force, United States Air Force Europe, 65 CONS, 65 CONS/LGC, Lajes Field, Azores APO, AE, 09720
 
ZIP Code
09720
 
Solicitation Number
FA4486-05-R-0005
 
Response Due
3/11/2005
 
Archive Date
3/26/2005
 
Description
Questions and answers pertaining to Solicitation FA4486-05-R-0005 1) T-572, can the door be put on the outside of the facility? Answer: YES. NOTE: If the door is to be installed on the inside exact, dimensions of existing door do not have to be met, would like to see submittals first. 2) T-606, Just to clarify, the minimum height of the only door being replaced must be 14' Confirmation: YES 3) B-572, there is no space to install the door on the inside of the building because there is a mezanine floor in the way. Should the contractor do the necessary modifications in order to accomodate the new door. Answer: YES, if the door is going on the outside. At this point it looks like outside installation is the preferable method. 4) Bldg T-216 has five roll-up doors. Scope of work states to remove and replace four doors. Please clarify and indicate which are to be removed. Answer: Only four doors, entry door, first door on left as you enter the building, both tire shop doors. 5) Bldg T-611, Two doors on the east side of the building have block glass windows located above the doors. Are the they to be replaced with CMU block? Answer: NEGATIVE. Just the one at T-606 6) We don't have any indication of where we're going to get power for the doors and the location of the panels. Answer: Power requirements are not available in T-611; therefore, use standard mechanical rolling doors instead. 7) Do we have to install a safety switch on each door. Answer: All roll-up doors must have safety switches and a manual chain as well 8) Which is the voltage and the Cycles. Answer: all electrical door motors will be 50Hz 9) In the existing panels, are there spare circuit breakers. Answer: T-715 existing electrical panel is located within 15ft of existing door and spare breakers are available. T-216 3 existing doors are all electrical operated and can be tied into the existing electrical panels. One (1) electrical door was replaced with a manual door, but was at one time electric. New conduit would have to be run and wire pulled to power this door and spare breaker is available.
 
Place of Performance
Address: 65th Civil Engineering Squadron, Lajes Field, Azores
Zip Code: 09720
Country: Portugal
 
Record
SN00761927-W 20050305/050303211946 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.