49 -- UPGRADE HEATING INDUCTION UNIT

Notice Date
10/20/2004
 
Notice Type
Solicitation Notice
 
NAICS
334512 — Automatic Environmental Control Manufacturing for Residential, Commercial, and Appliance Use
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC, Norfolk Naval Shipyard Annex, Building 1500 Code 530, 2nd Floor, Portsmouth, VA, 23709-5000
 
ZIP Code
23709-5000
 
Solicitation Number
N00181-05-Q-0009
 
Response Due
10/27/2004
 
Archive Date
11/10/2004
 
Description
This is a combined synopsis/solicitation prepared in accordance with FAR 13 with the format as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a separate written solicitation will not be issued. Solicitation number N00181-05-Q-0009 is issued as a Request for Quotation and Request for Quotations are being requested. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 01-11 and the Defense Federal Acquisition Regulations Supplement 1998 Ed. The NAICS classification is 334512 with a business size standard of 500 employees. Fleet Industrial Supply Center, Norfolk Naval Shipyard Annex intends to make award for a turn-key installation for the following Services: Provide material and services to upgrade existing Miller Induction Heating Unit for wireless temperature monitoring. Material provided shall include a wireless temperature transmitter panel and a wireless temperature receiving panel. The temperature transmitter panel shall include the following: (1) One each, 12 inches x 14 inches fiberglass enclosure with shaft connection straps. (2) Three each, thermocouple to 4-20MA converters. (3) One each, four channel, 4-20MA analog input module. (4) One each, wireless transmitter. (5) Two each, 12 hour rechargeable batteries. (6) One each, battery charger. (7) One each, ?wireless link ok? indicator light. (8) One each, ?battery ok? indicator light. (9) One each, On/Off switch. The Temperature Receiver Panel shall include the following: (1) One each 12 inches x 14 inches fiberglass enclosure. (2) One each, four channel, 4-20MA analog output module. (3) One each, wireless receiver. Services provided shall include the following: (1) Create Autocad documentation to include component layout of diagram schematics for the transmitter panels, receiver panels and the interface between the receiver panel and existing equipment. (2) Determine interface wiring requirements between Norfolk Naval Shipyard?s existing Miller Induction Heating Equipment and wireless temperature receiver panel. (3) Install and connect wireless temperature receiver panels to existing Miller Induction Heating equipment at Norfolk Naval Shipyard. (4) Perform system operation checks at Norfolk Naval Shipyard after installation to demonstrate acceptable system operation (5) Train shipyard personnel on monitoring system operation. Inspection and Acceptance at Destination. FAR clauses 52.212-1, 52.212-3, 52.212-4, 52..212-5 incorporating 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.232.33 as applicable. ADDENDA: 252.212-7001 incorporating 252.225-7001, DFAR 242.204-7004 REQUIRED CENTRAL REGISTRATION. LACK OF REGISTRATION IN THE CCR DATABASE WILL MAKE AN OFFEROR INELIGIBLE FOR AWARD. All responses must include a completed cop of the certifications and representations set forth in FAR 52.212-3. Parties responding to this Request for Quotations may submit their quote in accordance with their standard commercial practices (e.g. company letterhead, formal form quote, etc.) but must include the following information: (1) Complete mailing address address/remittance address; (2) Prompt payment discount; (3) anticipated delivery; (4) Taxpayer ID number TIN; (5) All completed certifications as required herein. All responses must be received by 2:00 P.M. local time, October 27, 2004. Questions/responses relative to this Request for Quotations may be faxed to (757)396-8277; email: Barneses@nnsy.navy.mil or mailed to: FISC, Norfolk Naval Shipyard Annex, Attn: Ernestine Barnes, Code 532.2F, Bldg 1500, 2nd Floor, Portsmouth, VA 23709-5000. Telephone requests will not be accepted. Text of clauses may be found at the following websites: FAR www.arnet.gov/far; DFAR www.dtic.mil/dfar. Information releative to CCR may be obtained via 1-888-227-2423 or http://www.ccr.gov. This is a combined synopsis/solicitation prepared in accordance with FAR 13 with the format as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a separate written solicitation will not be issued. Solicitation number N00181-04-Q-0669 is issued as a Request for Quotation and quotes are being requested. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 01-11 and the Defense Federal Acquisition Regulations Supplement 1998 Ed. The NAICS classification is 334512 with a business size standard of 500 employees. Fleet Industrial Supply Center, Norfolk Naval Shipyard Annex intends to make award for the following Services: Provide material and services to upgrade existing Miller Induction Heating Unit for wireless temperature monitoring. Material provided shall include a wireless temperature transmitter panel and a wireless temperature receiving panel. The temperature transmitter panel shall include the following: (1) One each, 12 inches x 14 inches fiberglass enclosure with shaft connection straps. (2) Three each, thermocouple to 4-20MA converters. (3) One each, four channel, 4-20MA analog input module. (4) One each, wireless transmitter. (5) Two each, 12 hour rechargeable batteries. (6) One each, battery charger. (7) One each, ?wireless link ok? indicator light. (8) One each, ?battery ok? indicator light. (9) One each, On/Off switch. The Temperature Receiver Panel shall include the following: (1) One each 12 inches x 14 inches fiberglass enclosure. (2) One each, four channel, 4-20MA analog output module. (3) One each, wireless receiver. Services provided shall include the following: (1) Design and manufacture of wireless transmitter and receiver panels. (2) Create autocad documentation. (3) Determine interface wiring requirements between Norfolk Naval Shipyard?s existing Miller Induction Heating Equipment and wireless temperature receiver panel. (4) Install and connect wireless temperature receiver panels to existing Miller Induction Heating equipment at Norfolk Naval Shipyard. (5) Perform system operation checks at Norfolk Naval Shipyard. (6) Train shipyard personnel on monitoring system operation
 
Place of Performance
Address: Norfolk Naval Shipyard, Portsmouth, VA
Zip Code: 23709-5000
 
Record
SN00696892-W 20041022/041020212150 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.