Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 17, 2004 FBO #1026
SOLICITATION NOTICE

61 -- BOM Modular Housing Project Completion

Notice Date
9/15/2004
 
Notice Type
Solicitation Notice
 
NAICS
423610 — Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
 
Contracting Office
US Army Engineer District, Philadelphia, 100 Penn Square East, Wanamaker Bldg (RM 643), Philadelphia, PA 19107-3390
 
ZIP Code
19107-3390
 
Solicitation Number
W912BU-04-T-0107
 
Response Due
9/20/2004
 
Archive Date
11/19/2004
 
Small Business Set-Aside
Total Small Business
 
Description
The U.S. Army Corp of Engineers, Philadelphia District, is issuing a Request for Quote (RFQ) to acquire electrical BOM for the completion of the Modular Housing Project at Kandahar Airfield, Afghanistan. Request for Quote (RFQ) Number W912BU-04-T-01 07 has been assigned. The NAICS Code is 423610, with a size standard of 500 employees. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.603, as supplemented with additional information in cluded in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. The solicitation document and incorporated provisions and clauses are those in effect through Federal Ac quisition Circular, 2001-20. The following is a list of line items: a. 10 EA 500 kva 4160 Volt: Transformer, pad mount: 500 kVA 4160 volt delta primary, 208/120; volt wye secondary, 60 Hz, type OA, 65 degree C rise, 60kV BIL, Bay-o-net primary fuse, Primary taps plus/minus 2-1/2%, Dead front with six 200 amp wells & load break inserts, drain valve, ANSI four hole low voltage spade, liquid level gauge, sample valve, 4 position T blade sectionalizing HV switch (loop/radial), tabs to allow bolted mounting to pad, LO bonded to transformer case. b. 10,000 lf ( 4 X 2,500 lf rolls), 500 MCM LV cable, RHH/RHW USE- c. 44 ea Panel enclosure, NEMA 3R, Square D, #HC3264WP, no substitutions d. 44 ea 400A Interior, I-Line, Square D, #HCM14644M, no substitutions e. 200 ea 225 Amp Circuit Breaker, I-Line, 3 pole, Square D, #KA3640035, no substitutions f. 100 ea Ground bar kit, Square D, PK32DGTA, no substitutions g. 44 ea Neutral bars, Square D, #HC4SN, no substitutions h. 100ea Blank Fillers, Square D, #HNM4BL, no substitutions i. 100 ea 500 MCM, Mechanical Lug, Burndy, #KA34-U, or equal j. 50 ea 500 MCM, Mechanical Lug, Thomas & Betts, #ADR60-21, or equal, or equal k. 50 ea Transformer locks, Wilson Bohannan Co., lock type 65310 1 62773 A, or equal l. 150 ea Grounding Clamp, Thomas & Betts, #JAB34H, or equal m. 30ea 2/0 Inline Splice Kit, Thomas & Betts, 15PCJ1-H-2250-TS, or equal n. 2 ea 100ft X 1 inch (or smaller)Rolls, Sand paper, 120 Grit. Delivery is required FOB Destination to Kandahar, Afghanistan within 30 calendar days after receipt of order. The provision at FAR 52.212-2, Evaluation Commercial Items applies. The evaluation factors are price and delivery with delivery more important t han price. The provision at FAR 52.212-3, Offeror Representative and Certifications- Commercial Items, must be completed and returned with the offer. The provisions at 52.212-1, 52.212-4 and 52.212-5 apply. Standard commercial warranties are acceptable for all items. The above provisions are available for download at http://farsite.hill.af.mil/. This action is set aside for small business. All responsible sources may submit a quote that shall be considered. The Government will not pay for information received. Bonding is not required. All contractors are required to be registered in the DODs Central Contract Register (CCR) before award as required by DFARS 204.7300. Information on getting registered may be obtained by phoning 1-888-227-2423 or by a ccessing the following Internet website: http://www.ccr.gov. Also, contractors who receive a federal contract of $25,000.00 or more are required by legislation to submit an annual VETS-100 Report on your employment of targeted veterans. Information on subm itting your report may be obtained by calling 703-461-2460 or by accessing the following Internet web site: http://vets100.cudenver.edu. This procurement is restricted for small business. Award will be made in the aggregate and not split. Please fax resp onses to (Attn: K. Johnson) at (215) 656-6798.
 
Place of Performance
Address: US Army Engineer District, Philadelphia 100 Penn Square East, Wanamaker Bldg (RM 643) Philadelphia PA
Zip Code: 19107-3390
Country: US
 
Record
SN00674188-W 20040917/040915212624 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice