Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 19, 2004 FBO #0997
SOLICITATION NOTICE

41 -- fan, vaneaxial

Notice Date
8/17/2004
 
Notice Type
Solicitation Notice
 
NAICS
333412 — Industrial and Commercial Fan and Blower Manufacturing
 
Contracting Office
Defense Logistics Agency, Logistics Operations, Defense Supply Center Philadelphia - General & Industrial, 700 Robbins Avenue, Philadelphia, PA, 19111-5096
 
ZIP Code
19111-5096
 
Solicitation Number
SP0560-04-R-0297
 
Response Due
10/3/2004
 
Archive Date
10/18/2004
 
Point of Contact
William Zera, Contract Specialist, Phone 215-737-5163, Fax 215-737-5187, - Tiffanie Reed, Contract Specialist, Phone 215-737-5164, Fax 215-737-5187,
 
E-Mail Address
William.Zera@dla.mil, tiffanie.reed@dla.mil
 
Description
PR YPI04194001829 NSN 4140-00-516-5002 ITEM DESCRIPTION: FAN, VANEAXIAL 440 VOLTS AC,60 HZ,THREE PHASE IAW CUTSHEET MIL-F-18953B(SH), DATED 22 OCTOBER 1990 SHALL BE MODIFIED AS FOLLOWS: PARA 2.1.1 (PAGE 2) - CHANGE "TT-P-664 PRIMER COATING, ALKYD, CORROSION-INHIBITING, LEAD AND CHROMATE FREE, VOC - COMPLIANT" TO READ "TT-P-645 PRIMER, PAINT, ZINC-MOLYBDATE, ALKYD TYPE." PARA 2.1.2 (PAGE 3) - REVISE VANEAXIAL FAN DWG. "810-921784" TO READ "803-921784" AND DELETE "810-921984 PERFORMANCE CURVES, VANEAXIAL FANS." PARA 2.2 (PAGE 4) - DELETE ASTM D 2092. PARA 3.2, TABLE I (PAGE 5) - UNDER "SAND CASTINGS" AND COLUMN UNDER "REQUIREMENT" AFTER "OR 713.0" ADD "; OR 356-T6." PARA 3.2.1.1.A (PAGE 5) - AFTER "ASTM B633, SC4" DELETE REMAINDER OF SENTENCE AND SUBSTITUTE." TYPE 2, FOLLOWED BY TWO (2) COATS (1 MIL MINIMUM DRY FILM THICKNESS EACH) OF YELLOW PRIMER CONFORMING TO TT-P-645 WITH THE COLOR NUMBER BEING LEFT UP TO THE MANUFACTURER. ALL PARTS IN CONTACT WITH AIR STREAM ARE TO BE GIVEN A FINAL COAT (1 MIL MDFT) OF PHENOLIC VARNISH IN ACCORDANCE WITH TT-V-119, TO SEAL PRIMER IN THE AIR STREAM. TOTAL THICKNESS OF ALL COATS SHALL BE BETWEEN 3 TO 4 MILS DRY FILM THICKNESS." PARA 3.2.1.1.B (PAGE 5) - AFTER "ASTM A 123" INSERT "FOLLOWED BY TWO (2) COATS (1 MIL MDFT EACH) OF YELLOW PRIMER CONFORMING TO TT-P-645 WITH THE COLOR NUMBER BEING LEFT UP TO THE MANUFACTURER. ALL PARTS IN CONTACT WITH AIR STREAM ARE TO BE GIVEN A FINAL COAT (1 MIL MDFT) OF PHENOLIC VARNISH IN ACCORDANCE WITH TT-V-119, TO SEAL PRIMER IN THE AIR STREAM. TOTAL THICKNESS OF ALL COATS SHALL BE BETWEEN 3 TO 4 MILS DRY FILM THICKNESS." PARA 3.2.1.1.C (PAGE 5) - CHANGE THE PARAGRAPH TO READ AS FOLLOWS: "ONE (1) COAT (2 TO 3 MILS MDFT) OF EPOXY PRIMER CONFORMING TO MIL-P-24441, FORMULA 150, FOLLOWED BY TWO (2) COATS (1 MIL MDFT EACH) OF YELLOW PRIMER CONFORMING TO TT-P-645 WITH THE COLOR NUMBER BEING LEFT UP TO THE MANUFACTURER. ALL PARTS IN CONTACT WITH AIR STREAM ARE TO BE GIVEN A FINAL COAT (1 MIL MDFT) OF PHENOLIC VARNISH IN ACCORDANCE WITH TT-V-119, TO SEAL PRIMER IN THE AIR STREAM. TOTAL THICKNESS OF ALL COATS SHALL BE BETWEEN 5 TO 7 MILS DRY FILM THICKNESS." PARA 3.2.1.1.D (PAGE 5) - DELETE PARAGRAPH. PARA 3.2.2.1 (PAGE 6) - DELETE THE SECOND AND THIRD SENTENCES AND SUBSTITUTE, "THE FASTENER SHALL BE OF 300-SERIES CORROSION-RESISTANT STEEL COATED WITH ZINC-RICH ANTI-SEIZE COMPOUND PRIOR TO INSTALLATION. OTHERWISE, STEEL FASTENER WITH CERAMIC COATING TO MIL-C-81751 SHALL BE USED." PARA 3.2.3.2 (PAGE 6) - LAST SENTENCE AFTER "ASSEMBLY" ADD "TOTAL DRY FILM THICKNESS FOR EACH COATING IS 2 TO 3 MILS. TOTAL OF ALL COATS IS A NOMINAL 6 MILS DRY FILM THICKNESS." PARA 3.3.2.2 (PAGE 7) - LAST SENTENCE AFTER "CASING" ADD "DIAMETER,". PARA 3.3.2.6.4 (PAGE 9) - CHANGE THE FOURTH SENTENCE TO READ "FOR TYPE A AND X-A FANS, THE OUTSIDE DIAMETER (OD) OF THE IMPELLER RIM SHALL BE AT LEAST AS GREAT AS THE OD OF THE MOTOR MOUNTING FLANGE. FOR TYPE L AND X-L FANS, THE OD OF THE IMPELLER RIM SHALL BE NO GREATER THAN THE OD OF THE MOTOR MOUNTING FLANGE." PARA 3.3.2.7 TABLE III (PAGE 10) - REVISE MIN. FRAME COLUMN UNDER FAN TYPE L1 FROM "48" TO READ "48/SPECIAL". UNDER COLUMN LOCK ROTOR CURRENT, CHANGE "(56)1" TO READ "(48)1." UNDER FAN TYPES "L1/2" AND "L1" AND COLUMN "MOTOR EFF. (PERCENT)." DELETE "53" AND "46." PARA 3.3.2.7.1.B (PAGE 11) - AFTER "FOR SINGLE PHASE POWER -" ADD "EITHER SPLIT PERMANENT CAPACITOR OR." PARA 3.3.2.7.1.D (PAGE 11) - AFTER "INSULATION" DELETE THE PARAGRAPH AND INSERT "CLASS F SEALED INSULATION - MOTOR TEMPERATURE RISE NOT TO EXCEED 55 DEG C." PARA 3.3.2.7.2 (PAGE 11) - A. IN THE FIRST SENTENCE, AFTER "BALL BEARINGS CONFORMING TO" INSERT "FF-B-171 (ABEC-1) AS SPECIFIED IN 6.2.H." B. PARAGRAPH E. - AFTER "25 DEG C" ADD "FOR NUCLEAR APPLICATIONS, OR 35 DEG C FOR NON-NUCLEAR APPLICATIONS,". PARA 3.3.2.7.3 (PAGE 12) - INSERT BETWEEN THE THIRD AND FOURTH SENTENCES THE FOLLOWING: "FRACTIONAL HORSEPOWER MOTORS DO NOT NEED TO HAVE THE ROTOR TACK WELDED TO THE SHAFT IF THE INTERFERENCE FIT BETWEEN THE ROTOR AND SHAFT IS A MINIMUM OF .0008 INCH." DELETE "OD" IN THE FOURTH SENTENCE AND INSERT "OUTER DIAMETER." PARA 3.3.2.7.6 (PAGE 12) - DELETE SECOND AND THIRD SENTENCES AND ADD "FOR DRAINAGE IN THE HORIZONTAL POSITION, APPLICABLE TO INTEGRAL AND FRACTIONAL FRAME MOTORS, FOUR DRAINS IN ONE END OF THE FRAME OR ON THE PERIPHERY IN ONE BRACKET SHALL BE SPACED 90 DEGREES APART PLUS (+) OR MINUS (-) 20 DEGREES USING THE CONDUIT CENTERLINE OR STUFFING TUBE CONNECTION AS A REFERENCE POINT. PARA 3.3.3.1 (PAGE 13) - REVISE TO READ AS FOLLOWS: "3.3.3.1 AERODYNAMIC PERFORMANCE. THE DESIGN POINT FOR EACH SIZE VANEAXIAL FAN SHALL BE THE VOLUME-PRESSURE POINT AS SPECIFIED IN TABLE IV. THE VOLUME SHALL BE THE VOLUME AT THE FAN INLET AND THE PRESSURE SHALL BE THE TOTAL PRESSURE (PT) IN THE WATER GAUGE (WG) AT THE FAN DISCHARGE. THE VOLUMETRIC FLOW RATE SHALL NOT EXCEED A RANGE OF -2% TO +5% OF THE APPLICABLE BASE CURVE ON DRAWING 803-921784 AS MEASURED ON A SYSTEM LINE. THE UPPER AND LOWER BOUNDS OF THIS STABLE OPERATION REGION ARE AS INDICATED IN FIGURE 1. THROUGHOUT THIS REGION, THE FAN SHALL EXHIBIT STABLE OPERATION." PARA 3.3.3.3.4 (PAGE 14) - IN THIRD SENTENCE DELETE "DRAWING 810-921784" AND ADD "DRAWING 803-921784." PARA 3.3.4.1 (PAGE 16) - CHANGE THE THIRD SENTENCE TO READ "THE TP SHALL RISE CONTINUALLY FROM FREE DELIVERY THROUGH THE DESIGN POINT TO 85% OF THE DESIGN VOLUME AS SPECIFIED IN TABLE VI. REVISE DWG. NO. "803-921784" TO READ "810-925368." AFTER LAST SENTENCE ADD "SEE FIGURE 1." PARA 3.6.1 (PAGE 19) - UNDER "SYMBOL SEQUENCE 5 (LETTER)" AND COLUMN UNDER "MEANING" DELETE "SUBMERSIBLE - 15 FOOT" AND ADD "WATERTIGHT." QPL APPLIES TECH DATA AVAILABILITY: CRITICAL APPLICATION ITEM I/A/W SPEC NR MIL-F-18953B BASIC DTD 90 OCT 22 AMEND NR DTD TYPE NUMBER A20A4W6 PRLI 000100 10 EA QTY VARIANCE: PLUS % MINUS % INSP/ACCEPT POINT: PREP FOR DELIVERY: PKGING DATA - MIL-STD-2073-1D, 15 DEC 1999 QUP = 001: PRES MTHD = 10: CLNG/DRY = X: PRESV MAT = XX: WRAP MAT = XX: CUSH/DUNN MAT = XX: CUSH/DUNN THKNESS = X: UNIT CONT = XX: OPI = O: PACK CODE = U: INTRMDTE CONT = XX: INTRMDTE-CONT-QTY = AAA: MARKING SHALL BE IN ACCORDANCE WITH MIL-STD-129. SPECIAL MAR KING CODE: ZZ - SPECIAL REQUIREMENTS. PALLETIZATION SHALL BE IN ACCORDANCE WITH D001450000 REV DATED 92278 SUPPLEMENTAL INSTRUCTIONS PACKAGE IAW MIL-F-18953. SEE CLAUSE 52.211-9G22, SECTION F, CODE F8, FOR D001450000 PALLETIZATION REQUIREMENTS. WHENEVER POSSIBLE AND PERMITTED BY THE TERMS OF THE CONTRACT, AVOID THE USE OF PLASTICS AS WRAPPING, CUSHIONING, OR DUNNAGE MATERIALS. For all shipments of packaged materiel to the government, which includes either depot (DLA-direct) or DVD (customer- direct) shipments, both DoD linear and 2-D bar code markings are required on military shipping labels in accordance with MIL-STD-129, revision P, dated December 15, 2002. 2-D bar coding shall be in accordance with ISO/IEC 15438, ISO/IEC 15434 (ANSI MH10.8.3) and DoD 4500.9-R. MSL linear (code 3 of 9 or code 39) bar coding shall be in accordance with ISO/IEC 16388. MSL label stock quality shall meet MIL-PRF-61002. MSL bar code print quality shall meet ANSI MH10.8-2000 or ANSI X3.182-1990 (R2000) for applicable 2-D and/or linear bar codes. All DVD shipments shall meet additional linear bar coding requirements in DLAD 52.211-9008. When the contract/order omits any data element required to be bar-coded, the field shall be zero-filled. These requirements do not apply to delivery orders when the basic contract has not been modified to require MIL-STD-129P. If there are inconsistencies between the schedule and MIL-STD-129P, the schedule takes precedence. DELIVER FOB: BY: PARCEL POST ADDRESS: SW3218 DEF DIST DEPOT SAN DIEGO 2680 WODEN STREET SAN DIEGO CA 92136-5491 FREIGHT SHIPPING ADDRESS: SW3218 DEF DIST DEPOT SAN DIEGO 2680 WODEN STREET RECEIVING BLDG 3304 SAN DIEGO CA 92136-5491 NON-MILSTRIP RDD 4344 PROJ END OF PR
 
Place of Performance
Address: DEFENSE SUPPLY CENTER PHILADELPHIA, 700 ROBBINS AVE, PHILADELPHIA, PA 19111
Zip Code: 19111
Country: USA
 
Record
SN00645106-W 20040819/040817211651 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.