Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 16, 2004 FBO #0963
SOURCES SOUGHT

93 -- Polymer additive to standard asphalt paving mix which produces an impermeable and extremely dense pavement which eliminates the need for an intermediate waterproofing membrane

Notice Date
7/14/2004
 
Notice Type
Sources Sought
 
NAICS
324121 — Asphalt Paving Mixture and Block Manufacturing
 
Contracting Office
US Army Engineer District, New England, 696 Virginia Road, Concord, MA 01742-2751
 
ZIP Code
01742-2751
 
Solicitation Number
W912WJ-04-X-0001
 
Response Due
7/29/2004
 
Archive Date
9/27/2004
 
Point of Contact
annmarie.beauregard, 978-318-8668
 
E-Mail Address
US Army Engineer District, New England
(annmarie.beauregard@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
PROJECT: DECK REPAIRS AND WATERPROOFING PAVEMENT, SAGAMORE HIGHWAY BRIDGE, BOURNE, MA THIS IS NOT A SOLICITATION. The U.S. Army Corps of Engineers, New England District, is issuing this sources sought announcement to request submissions from companies that manufacture additives for bituminous highway paving mixtures as described. The produ ct process shall be a polymer additive which is added to a standard highway paving mix at the asphalt plant. When placed and compacted, the in-place pavement shall be such that the void space is reduced to the point at which the pavement is considered wat erproof and a waterproofing membrane is not required, and the density is increased to the point at which potholes and rutting are minimized or totally eliminated. Documentation of these properties shall be based on the product/process meeting the criteria of the following tests and requirements. Test for Fatigue Rating: This test shall compare an unmodified AC 20 asphalt mix with a similar asphalt mix with the specific additive as part of the mix binder to assess fatigue resistance. The samples shall be t ested according to AASHTO TP 8, “Standard Test Method for Determining the Fatigue Life of Compacted Hot Mix Asphalt (HMA) Subjected to Repeated Flexural Bending.” The beam fatigue testing shall be conducted at a test temperature of 25 degrees C, a loading frequency of 5 Hertz, and a tensile strain level of 600 microstrains. Samples shall be compacted to 7 plus or minus 1 percent air voids for testing. Fatigue failure is defined as the number of fatigue cycles which correspond to a 50 percent re duction in the initial beam stiffness. Results shall be considered to meet criteria, that is, shall be considered to have sufficient fatigue resistance, when each sample of the modified mix demonstrates a minimum fatigue resistance of 250,000 cycles at 25 degrees C and at least three times that of the unmodified AC 20 binder mix as determined by AASHTO TP 8. Test for Rut Resistance: The object of this test shall be to evaluate the rutting characteristics of the additive modified asphalt mixture under test w heel loadings at elevated temperatures. Two types of hot mix asphalt mixtures shall be used; one a neat AC 20 asphalt binder, and the second using the same AC 20 binder modified with the proposed additive. The aggregate for both asphalt mixes shall be th e same. Three Marshall samples shall be prepared for each HMA per ASTM D1559. The compaction machine and procedures used for fabricating the asphalt beams shall be according to State of Georgia DOT GDT 115 Specifications. The loaded wheel testing shall b e performed according to Georgia DOT GDT 115. Tests shall be performed at 40 degrees C and 60 degrees C. Results shall be considered to meet criteria when the following values are met or exceeded: The rut depth, in inches, for the AC 20 with additive sam ple is a maximum of half the value for the neat AC 20 sample. The following minimum rut depths for the AC 20 with additive sample, tested at 40 degrees C shall not exceed the following values: For 1000 cycles a maximum rut depth of 0.04 inches; for 8000 c ycles a maximum rut depth of 0.05 inches. The following minimum rut depths for the AC 20 with additive sample, tested at 60 degrees C shall not exceed the following values: For 1000 cycles a maximum rut depth of 0.15 inches; for 8000 cycles a maximum rut d epth of 0.20 inches. Test for Resistance to Chloride Ion Penetration: This test shall measure the resistance of a concrete specimen with an asphalt coating containing the special additive binder applied to its surface to the penetration of chloride ion. T esting shall be performed in general accordance with AASHTO T259, Resistance of Concrete to Chloride Ion Penetration. Four concrete test specimens shall be made and cured according to AASHTO T126. Each slab shall be not less than 3 inches thick and twelve inches square. The specimens shall be moist cured for 14 days and placed in a drying room for 7 days according to AASHTO T160. Each specimen shall then be removed from the drying room and be coated with a standard highway asphalt mix with additive contained in the binder. When the specimens have cooled to ambient temperature, they shall be returned to the drying room for 7 days. At that time they shall be removed from the drying room, the dams built around the top edges of the specimens, and returned to the drying room for a final 14 days. The degree of saturation of the specimens at the time of ponding will affect the chl oride ingress, i.e., water saturated concrete will absorb significantly less chlorides than a drier, but similar material. Thus, for proper definition of chloride ingress, the requirements for a total of 28 days drying time must be strictly adhered to. A t the end of the drying period, 42 days, three of the four specimens shall be subjected to continuous ponding with a three per cent sodium chloride solution approximately 0.5 inches deep for ninety days. The fourth specimen shall be the control. Glass pl ates shall be placed over the dams to retard evaporation of the solution and the specimens placed in the drying room for a ninety day period. After 90 days of exposure, the solution shall be removed from the specimen, the specimens shall be allowed to dry , and all salt crystal build up shall be removed from the surfaces. Samples shall then be taken from depths of 0.0625 inches to 0.5 inches, and from 0.5 inches to 1.0 inches per AASHTO T259. The chloride content shall then be determined for each sample in accordance with AASHTO T260. Results shall be considered to satisfy criteria, negligible transmission of chloride ions, when either no sample exceeds 0.03 percent chlorides, or no sample exceeds the percent chloride in the control by greater than 0.01 p ercent. Test for Impermeability: This test shall consist of preparing and testing compacted hot mix samples employing the specific additive in accordance with ASTM D 5084, Hydraulic Conductivity, via Falling Head, Rising Tail, to determine hydraulic con ductivity. Results shall be considered to meet criteria, asphalt pavement samples are essentially impermeable, when the Hydraulic Conductivity of each sample is equal to or less than 10 to the minus eighth power cm per sec. Test for Resilient Modulus: This test shall consist of preparing and testing laboratory-prepared Hot Mix Asphalt samples using the proposed additive as an integral part of the binder to determine resilient modulus of elasticity at varying temperatures. A ll testing shall be in accordance with ASTM D 4123 Indirect Tension Test for Resilient Modulus of Bituminous Mixtures. Results shall be considered to satisfy criteria when the modulus of elasticity of all samples equals or exceed 200,000 pounds per square inch at a test temperature of 25 degrees C. Test Values for Proposed Additive and Asphalt Binder Only: The following tests shall be performed on the proposed additive and asphalt binder, according to the referenced test methods indicated. Nominal required values are listed also. The Performance Gra de Test per AASHTO MP1 shall produce a nominal result of PG 94 34. The Dynamic Shear Ratio Test per AASHTO TP5 shall produce a nominal result of 1.034 kPa at 118 degrees centigrade. The Creep Stiffness Test per AASHTO TP3 shall produce a nominal result of 90 Mpa at minus 24 degrees centigrade. The Elastic Recovery Test per ASTM D6084 shall produce a nominal result of 92 percent at 10 degrees centigrade. The Force Ratio Test per AASHTO T300 shall produce a nominal result of 0.99. The Toughness Test per ASTM D5801 shall produce a nominal result of 210 inch pounds. The Tenacity Test per ASTM D5801 shall produce a nominal result of 140 inch pounds. Results shall be considered to satisfy criteria if all test result values fall within 5 percent of the nominal va lues listed above. Manufacturers shall submit written specifications, catalog cuts, and 3 customer references with greater than three years successful field installation of the product. Firm shall indicate whether it is small, large, disadvantaged, etc. The NAICS Code is 324121. This notice is for informational purposes only and is not a solicitation. POC is Ann Marie Beauregard at 978-318-8668. NOTE: THIS NOTICE WAS NOT POSTED TO WWW.FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (14-JUL-2004); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/USA/COE/DACA33/W912WJ-04-X-0001/listing.html)
 
Place of Performance
Address: US Army Engineer District, New England 696 Virginia Road, Concord MA
Zip Code: 01742-2751
Country: US
 
Record
SN00621164-F 20040716/040714213600 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.