Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 09, 2004 FBO #0895
SOLICITATION NOTICE

H -- Gas Free Certification

Notice Date
5/7/2004
 
Notice Type
Solicitation Notice
 
NAICS
541380 — Testing Laboratories
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Mayport Detachment, Fleet Contracting Center Bldg. 191, Naval Station Mayport, Mayport, FL, 32228-0107
 
ZIP Code
32228-0107
 
Solicitation Number
N68836-04-T-0172
 
Response Due
5/17/2004
 
Archive Date
6/1/2004
 
Point of Contact
Carolyn Wilson, Purchasing Agent, Phone 904-270-5699x147, Fax 904-270-6498, - Carolyn Wilson, Purchasing Agent, Phone 904-270-5699x147, Fax 904-270-6498,
 
E-Mail Address
carolyn.wilson1@navy.mil, carolyn.wilson1@navy.mil
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number N68836-04-T-0172 is issued as a request for quote (RFQ)and will be used for tracking purposes only, a written RFQ will not be issued. The solicitation document and incorporated provisions and clauses are those in effect through the latest edition of the Federal Acquisition Circular. This solicitation is issued on an unrestricted basis; the NAICS Code is 541380. SIMA Mayport requires a contract to provide chemist inspections and issuance of a marine chemist certificate aboard vessels at Mayport Naval Station, Mayport Florida 32228, for the base period 01 Jun 2004 through 31 May 2005, and two options years, approximately 60 services per year. Statement of work as follows: Gas Free Engineering (GFE) Services; Scope: Confined Space Entry & Certification; References: 2.1 - 29 CFR Part 1915, Occupational Safety and Health Standards for Shipyard Employment; 2.2 - 29 CFR Part 1910, Occupational Safety and Health Standards, Respiratory Protection. Requirements: 3.1 - Comply with the requirements of 2.1 and 2.2 and this statement of work to determine whether or not an explosive or other dangerous atmosphere exists in tanks, spaces, and associated piping, including adjacent tanks, spaces, and piping aboard the ship and control hot work and entry to those spaces to preclude damage to the ship or injury to personnel during the performance of this job order. 3.1.1 ? Submit one legible copy, in hard or electronic media, of a list of tanks or spaces to be opened or certified to the GFE Supervisor at least 24 hours prior to commencement of work. 3.1.2 ? Provide initial and annual update training for Competent persons by utilizing a National Fire Protection Association (NFPA) Certified Marine Chemist of NFPA training program meeting the requirements of Section 1915.7 of 2.1. The length of the initial training class shall be at least 24 hours. Annual update training shall be at least 8 hours. 3.2 ? Post a copy of the Marine Chemist?s certification, Certified Industrial Hygienist?s test/inspection record, or Competent Person?s test/inspection record at each access to the affected space while work in the space is in progress. A copy of the certificate or test/inspection record shall also be delivered to a location designated by the GFE Supervisor. In the event that the space is found to be NOT SAFE FOR WORKERS/NOT SAFE FOR HOT WORK, the space shall be posted accordingly and the GFE Supervisor shall be notified immediately. The posted copy shall be clearly visible and legible. 3.2.1 ? Initial certification of spaces that require a Certified Marine Chemist?s certificate or Certified Industrial Hygienist?s record of test/inspection in support of work operations shall be effective until conditions change. Thereby voiding the certificate/record of test/inspection. 3.2.2 ? For those certified spaces affected by hot work, a Competent Person shall visually inspect and test each space certified as SAFE FOR HOT WORK as often as necessary and, as a minimum, prior to entry by employees on a daily basis. 3.2.3 ? For those certified spaces affected by hot work, a competent person shall visually inspect and test each space certified as SAFE FOR HOT WORK as often as necessary and, as a minimum, daily prior to commencement of hot work to ensure that condition established by the certificate are maintained. When hot work is conducted continuously, the affected spaces shall be visually inspected, tested, and recorded on a daily basis to maintain SAFE FOR HOT WORK certification. 3.2.4 ? If a competent person finds that the conditions within a certified space fail to meet the applicable requirements for which it was certified, work in the space shall be stopped and may not be resumed until the space has been re-certified by a Marine Chemist. 3.2.5 ? For those spaces where only a competent person tests and inspections are required in accordance with 2.1, a competent person shall visually inspect and test each space as often as necessary and, as a minimum, daily prior to entry or commencement of hot work to ensure that conditions are safe. 3.2.6 ? After the competent person has determined initially that a space is safe for entry and finds subsequently that the conditions within the test space fail to meet the requirements of 2.1, work shall be stopped until the conditions in the test space are corrected, the space is retested, and a new record of tests/inspections is recorded and posted. The following clauses and provisions apply: 52.212-1 Instructions to Offerors-Commercial Items; 52.212-3 Offeror Representations and Certifications-Commercial Items; 52.212-4 Contract Terms and Conditions-Commercial Items; 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, and citing: 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.222-41, 52.222-42; 252.204-7004 Central Contractor Registration; 252.212-7001 Contract Terms and Conditions Required to Implement Statutes Applicable to Defense Acquisition of Commercial Items, and citing: 252.225-7001; Offers are due by close of business 17 May 2004 and may be emailed or faxed to 904/270-6498. Point of Contact is Carolyn Wilson, Ph 904/270-5699 x147
 
Place of Performance
Address: Naval Station Mayport Florida
Zip Code: 32228
Country: US
 
Record
SN00582102-W 20040509/040507212440 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.