Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 09, 2004 FBO #0865
SOLICITATION NOTICE

63 -- GENERATOR C02 SYSTEM UPGRADE REPLACE EXISTING C02 BOTTLES, CONTROL PANELS, VALVES, AND CONTROLS CURRENTLY PROTECTING TWO GENERATORS AT ANDERON RANCH DAM. EXISTING PIPING, DETECTION, AND REMOTE RELEASES TO STAY.

Notice Date
4/7/2004
 
Notice Type
Solicitation Notice
 
Contracting Office
BUREAU OF RECLAMATION SNAKE RIVER AREA OFFICE WEST 230 COLLINS RD, BLDG 1A BOISE ID 83702
 
ZIP Code
83702
 
Solicitation Number
04SQ110050
 
Response Due
4/23/2004
 
Archive Date
4/7/2005
 
Point of Contact
MARIE DAY PURCHASING AGENT 2083832228 MDAY@PN.USBR.GOV;
 
E-Mail Address
Email your questions to Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
Total Small Business
 
Description
This announcement constitutes a combined Synopsis Solicitation prepared in accordance with the format FAR 12.6 for Generator C02 System Upgrade for the Bureau of Reclamation Snake River Area at Anderson Ranch Dam. This RFQ No. 04SQ110050 incorporates provisions and clauses in effect through FAC 2001-21. PROPOSALS SHALL INCLUDE THE COMPLETED FAR CLAUSE 52.212-03 OFFEROR REPRESENTATIONS AND CERTIFICATIONS - COMMERCIAL ITEMS - WITH THEIR QUOTATTION. Vendors may access the referenced FAR clauses at the following website: WWW.ARNET.GOV/FAR. All responses are due by COB 4/23/04. The Government anticipates award of a firm fixed price contract resulting from this solicitation on or about April 26, 2004 that is most advantageous to the Government. This is a total small business set aside, the NAICS code is 561621 (Security Systems Services) and the size standard is $10.5 million. The FPDS Code is 1230 - (Fire Control Systems - Complete) VENDORS ARE ENCOURAGED TO SUBMIT QUOTES ELECTRONICALLY TO THE FOLLOWING E-MAIL ADDRESS: MDAY@PN.USBR.GOV. They may also be faxed to the attention of Marie Day at 208-383-2237 or mailed to Bureau of Reclamation, 230 Collins Road, Boise, ID 83702. TECHNICAL QUESTIONS regarding this solicitation can be directed to FRED DIMICK at 208-587-4051. SECTION A - DESCRIPTION/SPECIFICATIONS SUBSECTION A.1 - GENERAL REQUIREMENTS A.1.1 Generator CO2 System Upgrade - Anderson Ranch Dam Replace existing CO2 cylinders, control panel, valves, and controls that are currently protecting two generators. Existing system has one set of 3 - 50lb. cylinders designed for initial automatic discharge and 2 -50 lb. cylinders designed for secondary manual discharge. Selector valve determines which generator requires CO2. Existing piping, detection and remote releases to stay. Available power for control panel is 125VDC. The following items will be required " Necessary CO2 Cylinders and 1 set of spare CO2 Cylinders. " Cylinder bracketing with weigh bar. " Discharge heads with discharge hoses, designed for single cylinder and multiple cylinder release. " DC control head, manual reset, no solenoid release valve. " Manual lever operated release heads. " Discharge indicator " Discharge nozzles " Check valves " Directional/stop valves " Lockout valves " DC input control panel. The control panel shall have 2 normally-open output contacts that will close with C02 discharge. The contacts shall be rated for 125 VDC. " Drawing/schematic showing set up design " Labor to commission system Note: All system components shall be from a single manufacturer. Available power for control panel is 125VDC only. DELIVERY SHALL BE ON OR BEFORE 5/28/2004 TO: BUREAU OF RECLAMATION, ANDERSON RANCH DAM, 20465 NE. SOUTH FORK RD, MOUNTAIN HOME, ID 83647 - ATTN: FRED DIMICK Following are the applicable provisions and contract clauses incorporated by reference. FAR 52.212-3 Offeror Representations and Certifications-Commercial Items; FAR 52.212-4. Contract Terms and Conditions-Commercial Items; FAR 52.212-5 paragraph (b) is tailored to incorporate the following clauses: FAR 52.219-6 Notice of Total Small Business Set Aside; FAR 52.222-3 Convict Labor; FAR 52.222-19 Child Labor - Cooperation with Authorities and Remedies; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-35 Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era and Other Eligible Veteran; FAR 52.232-33 Payment by Electronic Funds Transfer; FAR 52.204-6 Data Universal Numbering System (DUNS) Number ; paragraph (c) and FAR 52.204-07 Central Contractor Registration. To take advantage of business opportunities with BOR and DOI vendors must register their firm on the Central Contractor Registration System (CCR) @ http://www.ccr.gov.
 
Web Link
Please click here to view more details.
(http://ideasec.nbc.gov/ecprod/owa/ec$cbd.sypfirstcount?P_SERVER_ID3=BR142511&P_OBJ_ID1=11526)
 
Place of Performance
Address: ANDERSON RANCH DAM 20465 NE. SOUTH FORK ROAD MOUNTAIN HOME, IDAHO 83647
Zip Code: 837024520
Country: USA
 
Record
SN00561869-W 20040409/040407212554 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.