SOLICITATION NOTICE

41 -- 4120 - 75 Ton Air Conditioning and Heating Units

Notice Date
5/22/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC, Norfolk Naval Shipyard Annex, Building 1500 Code 530, 2nd Floor, Portsmouth, VA, 23709-5000
 
ZIP Code
23709-5000
 
Solicitation Number
N00181-02-Q-0494
 
Response Due
7/10/2002
 
Point of Contact
Nancy Hayden, Contract Specialist, Phone 757-396-8346, Fax 757-396-8503,
 
E-Mail Address
haydennm@nnsy.navy.mil
 
Description
The Fleet and Industrial Supply Center, Norfolk Naval Shipyard Annex proposes to contract for 75 Ton Heating and Air Conditioning Units in accordance with detailed specifications set forth in the solicitation. The units shall be enclosed, portable, high pressure capable of operating in an industrial shipyard environment exposed to rain, snow and wind blown dust with outdoor ambient temperatures between 20 degrees Fahrenheit to 95 degrees Fahrenheit with relative humidity ranging between 30 degrees and 100 degrees. The units shall be 46VAC, 3 Phase, rotary screw type compressor, not less than 900,000 BTU/HR cooling capacity. AC capable of conditioning 6,000 CFM; electric heaters capacity at least 421,000 BTU/HR (123KW). The maximum size of the units shall not exceed 17 feet 10 inches long X 10 feet wide X 10 feet 10 inches high. The total weight of the unit shall not exceed 18,000 LBS. The units shall be equipped with lifting pads to accommodate a four-point lift by crane and with box section tine guide openings in the base for safe handling and transport by forklift. The contract will be for a Base Quantity of 2 each with option quantities for an additional 14 units to be exercised in Fiscal Years 02 through 06 subject to availability of funds for delivery to Norfolk Naval Shipyard, Portsmouth, VA 23709-5000. Descriptive Literature will be required with all offers and will be identified in the solicitation. This requirement is being handled utilizing "SIMPLIFIED ACQUISITION PROCEDURES" as set forth in FAR Part 13 and authorized in FAR Part 13.5, Test Program for Certain Commercial Products. Request for solicitation packages will be accepted via mail and e-mail only. All requests shall include, as a minimum, the solicitation number, the complete mailing address, telephone number, fax number and point of contact for requestor. Written requests shall be addressed to Fleet and Industrial Supply Center, Norfolk Naval Shipyard Annex, Bldg. Code 531.4A.Nancy Hayden. E-mail address is: haydennm@nnsy.navy.mil. Fax and/or phone requests are not authorized and will not be accepted. IMPORTANT NOTICE: DFARS 252-204-7004 "REQUIRED CENTRAL CONTRACTOR REGISTRATION IN THE CCR DATABASE WILL MAKE AN OFFER/QUOTER INELIGIBLE FOR AWARD. INFORMATION CAN BE OBTAINED THROUGH INTERNET AT http://ccr.edi.disa.mil. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (22-MAY-2002). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 04-MAR-2004. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/DON/NAVSUP/N00189A/N00181-02-Q-0494/listing.html)
 
Record
SN00537640-F 20040306/040304235034 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice