SOLICITATION NOTICE

66 -- Power Supply and X-Ray Tube

Notice Date
2/20/2004
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Energy, Bechtel Nevada Corp (DOE Contractor), Bechtel Nevada, PO Box 98521, Las Vegas, NV, 89193
 
ZIP Code
89193
 
Solicitation Number
Reference-Number-Kucher
 
Response Due
3/1/2004
 
Point of Contact
Ann Elliott, Procurement Specialist, Phone 702-295-2936, Fax 702-295-9115, - Cheryl Furjanic, Senior Procurement Specialist, Phone 702-295-4694, Fax 702-295-2088,
 
E-Mail Address
elliotae@nv.doe.gov, furjancd@nv.doe.gov
 
Description
The following Power Supply and X-Ray tube requirements are obligatory to create a high energy X-Ray facility at Lawrence Livermore Laboratory. The source will have the capability to obtain an X-Ray Output Flux of 10,000,000 photons/cm2 per steradian; it will also have an X-Ray energy range of 8Kev-100Kev (fluoresced x-rays). The source will be used as a “characterization” tool for evaluating x-ray diagnostics used at the LLE OMEGA facility and the NIF during HEDP and ICF experiments. POWER SUPPLY REQUIREMENTS - A. Input Power: 195 to 230 VAC, 3-phase, 60Hz B. Output: Voltage: 0-160 KVDC, negative, continuously variable Current: 0-60 mA Filament: 0 to 10V at 0 to 6A DC C. Regulation: KV Stability: Short term: +- .02% of max. KV within a 10 min. period Long term: +-0.05% of max. KV wihin an 8 hour period Line Regulation: +-0.05% max. for line voltage range of 195V to 230 V Load Regulation: +-0.05% max. of max. KV from no load to full load at any vboltage level exceeding 1KV KV ripple: 0.05% rms max. of max. KV mA Stability: Short term: +-0.05 of max. mA within an 8 hour period D. Accuracy of Measurement KV accuracy: within +-500V of true high voltage output including short and long term drift mA accuracy: within .1mA of true conversion current including short and long term drift E. Dimensions Control/Regulator Section: 22"W x 58"H x 32"D approx. High Voltage: Section 40"D x 50"H x 34"D approx. X-Ray Tube specifications available upon request.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/DOE/BNC/BV/Reference-Number-Kucher/listing.html)
 
Place of Performance
Address: Lawrence Livermore Operations Laboratory
Country: United States
 
Record
SN00527320-F 20040222/040220232619 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.