Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 21, 2003 FBO #0724
SOLICITATION NOTICE

J -- POWER FEED UPGRADE

Notice Date
11/19/2003
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Mayport Detachment, Fleet Contracting Center Bldg. 191, Naval Station Mayport, Mayport, FL, 32228-0107
 
ZIP Code
32228-0107
 
Solicitation Number
N68836-04-T-0086
 
Response Due
12/3/2003
 
Archive Date
12/18/2003
 
Point of Contact
Carolyn Wilson, Purchasing Agent, Phone 904-270-5699x147, Fax 904-270-6498, - Carolyn Wilson, Purchasing Agent, Phone 904-270-5699x147, Fax 904-270-6498,
 
E-Mail Address
carolyn_b_wilson@jax.fisc.navy.mil, carolyn_b_wilson@jax.fisc.navy.mil
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number N68836-04-T-0086 is issued as a request for quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through the lastest edition of the Federal Acquisition Circular. This solicitation is issued as a small business set-a-side; The following clauses and provisions apply: 52.212-1 Instructions to Offerors-Commercial Items;52.212-3 Offeror Representations and Certifications-Commercial Items; 52.212-4 Contract Terms and Conditions-Commercial Items; 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items, and citing: 52.219-6,52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.222-41, 52.222-42; 252.204-7004 Central Contractor Registration; 252.212-7001 Contract Terms and Conditions Required to Implement Statutes Applicable to Defense Acquisition of Commercial Items, and citing: 252.225-7001; Offers are due by close of business 03 Dec 2003 and may be emailed to the address found below or faxed to 9904/270-6498. Point of Contact is Carolyn Wilson, Ph 904/270-5699 ext 147. STATEMENT OF WORK: POWER FEED UPDATE 1. OVERVIEW: THE FUEL SKID REHABILITATION PROJECT WILL INCREASE THE POTENTIAL ELECTRICAL LOAD FROM 600 TO 780 AMPS PER PHASE BY ADDING TWO NEW 75 HP HYDRAULIC PUMPS TO THE EXISTING LOAD. THE EXISTING POWER FEEDER CIRCUIT FROM THE BUILDING 795 SOUTH END MAIN SERVICE DISTRIBUTION PANEL IS PRESENTLY CAPABLE OF HANDLING THE EXISTING LOAD AND WILL HAVE TO BE UPSIZED TO COMPLY WITH THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE. 2. THE EXISTING MOTOR CONTROL CENTER IS CAPABLE OF HANDLING LOADS UP TO 1200 AMPERES PER PHASE, BUT DOES NOT HAVE SUFFICIENT SPACE FOR TWO NEW MOTOR CONTROLLERS, AND WILL REQUIRE A NEW VERTICAL SECTION. THE CONTRACTOR PERFORMING THE FUEL SKID REHAB PROJECT WILL SUPPLY THIS NEW VERTICAL SECTION OF THE MOTOR CONTROLLERS. HOWEVER, THE CONTRACTOR IS NOT REQUIRED BY THE CONTRACT TO UPGRADE THE POWER FEEDER CIRCUIT FROM THE MAIN SERVICE DISTRIBUTION PANEL. 3. ENGINEERING ANALYSIS HAS DETERMINED THAT THERE IS INSUFFICIENT SPACE IN THE EXISTING MAIN SERVICE PANEL DISTRIBUTION SECTIONS FOR A NEW 1000 AMP CIRCUIT BREAKER. A NEW 2000 AMP DISTRIBUTION SECTION AND HOUSEKEEPING PAD WILL BE REQUIRED, ALONG WITH A NEW 1000 AMP CIRCUIT BREAKER, CONDUIT, WIRE, HARDWARE, AND LABOR TO PROVIDE THE INCREASED CAPACITY. 4. IN PARTICULAR, THE CONTRACTOR WILL BE RESPONSIBLE FOR THE FOLLOWING: A. POUR A NEW HOUSEKEEPING PAD B. INSTALL A NEW DISTRIBUTION SECTION C. INSTALL A NEW 1000 AMP BREAKER D. INSTALL NEW CONDUIT FROM THE MAIN PANEL TO THE MOTOR CONTROL CENTER E. RUN NEW WIRES BETWEEN NEW BREAKER AND MOTOR CONTROL CENTER 5. THE TASKS NOTED IN (A) THROUGH (C) IN PARAGRAPH 4 MUST BE COMPLETED BEFORE THE NEW HYDRAULIC SYSTEM IS INSTALLED ON 12 JAN 2004. 6. AN ONSITE SURVEY OF THE AREA CAN BE ARRANGED BY CONTACTING EMILIO DEL ORBE AT 904/542-5951 X142 OR ADRIAN GRAY AT 904/542-5990 X143.
 
Place of Performance
Address: NAVAL AIR DEPOT, BLDG 795, NAVAL AIR STATION, JACKSONVILLE FL
Zip Code: 32212
Country: US
 
Record
SN00472857-W 20031121/031119212514 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.