Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 15, 2003 FBO #0532
SOURCES SOUGHT

29 -- 120 VAC panelboards and 24 VDC panelboards

Notice Date
5/13/2003
 
Notice Type
Sources Sought
 
Contracting Office
DHS - Direct Reports, United States Coast Guard (USCG), Commanding Officer, USCG Engineering Logistics Center, 2401 Hawkins Point Road Building 31, Mail Stop 26, Baltimore, MD, 21226-5000
 
ZIP Code
21226-5000
 
Solicitation Number
DTCG40-03-Q-40229
 
Response Due
5/20/2003
 
Point of Contact
Sandra Miller, Contract Specialist, Phone 410-762-6452, Fax 410-636-7458, - David Monk, Contracting Officer, Phone 410-762-6456, Fax 410-762-6056,
 
E-Mail Address
skmiller@elcbalt.uscg.mil, dmonk@elcbalt.uscg.mil
 
Small Business Set-Aside
Total Small Business
 
Description
17.Potential sources sought: The U. S. Coast Guard Engineering Logistics Center is seeking qualified sources that can provide International Marine Products (IMP) panel boards or equal. CLIN 0001. The salinet chracteristcis are 120 VAC, 60 Hertz, 6 circuit on the bottom of panel and 1 circuit in top of panel and seven 2 pole circuit breakers, 200 amp bus, with main lugs, hinged door with glass front NEMA 12 enclosure, surface mounted. Enclosure: NEMA 12 rating. 12" Wide x 16" Tall x 4.35" Deep including door. Constructed of 16-gauge steel with ANSI polyester powder coating, black in color inside and out over a phosphatized surface. Hinged steel frame door with a glass front that maintains the NEMA 12-ingress protection rating. The viewable area through the glass shall be large enough to allow all the circuit breakers and their labels be seen. Door shall be hinged on the left side when looking at the panel board. The hinge pins shall be easily removed so the door can be taken off. The door shall have a wing knob latch on the right side. Mounting ears shall be provided on the back of the enclosure for bulkhead mounting. Trim/Cribbage piece shall be made of 16-gauge steel with ANSI polyester powder coating, black in color over a phosphatized surface. It shall have an external flange 1? wide and an internal flange not more than ?? deep which slips over the outside of the enclosure. It shall be secured in place with fasteners through its face into the joiner work. With the Trim/Cribbage piece install flush with the enclosure door, it shall allow the door to open at least 150 degrees. The interior layout of the enclosure shall have the transformer breaker located at the top of the enclosure and the distribution circuits located below. The transformer breaker shall be physically separated (via a barrier) from the distribution circuits. Bus: Copper 200 Amp @ 248 VAC with main lugs. Circuit Breakers: Standard thermal-magnetic circuit breakers. All breakers shall be double-pole. UL 1077 Listed. IEC B98 Type Approval. Transformer circuit breaker interrupting capacity of 70kA @ 120/240 VAC Distribution circuit breakers interrupting capacity range of 14kA @ 120/240 VAC to 5kA @ 480 VAC, DC rating of 55V per pole, ambient temperature range of -25? C to +45?C. Shock resistant rating of 30g half sine shock load @ 6ms, and a vibration resistance rating of ? 6g. Selectable trip curves. The number of breakers, breaker trip ratings and number of polls required shall be as shown on the faceplate legend attached. Internal Construction: Lugged line side bus bar connected. DIN rail mounted components. All connections and bus work shall be insulated. Custom high-strength polycarbonate faceplate that doubles as a captive device for circuit breakers under high shock conditions. Faceplate shall be black with engraved circuit descriptions in white. Circuit arrangement shall be as shown on the faceplate legend attached. International Marine Products, Inc., Panel board Model Number: PS-AC-8-41 or Equal will meet these requirements. CLIN 0002: The salient characteristics are: 24 VDC, 24 circuits, 22 single pole breakers and 1 double pole main disconnect breaker, 250 amp bus, with main lugs, hinged door with glass front NEMA 12 enclosure, surface mounted. Enclosure: NEMA 12 16" Wide x 20" Tall x 4.35" Deep including door. Constructed of 16-gauge steel with ANSI polyester powder coating, black in color inside and out over a phosphatized surface. Hinged steel frame door with a glass front that maintains the NEMA 12-ingress protection rating. The viewable area through the glass shall be large enough to allow all the circuit breakers, their labels and meters be seen. Door shall be hinged on the right side when looking at the panel board. The hinge pins shall be easily removed so the door can be taken off. The door shall have a wing knob latch on the left side. Mounting ears shall be provided on the back of the enclosure for bulkhead mounting. Trim/Cribbage piece shall be made of 16-gauge steel with ANSI polyester powder coating, black in color over a phosphatized surface. It shall have an external flange 1? wide and an internal flange not more than ?? deep which slips over the outside of the enclosure. It shall be secured in place with fasteners through its face into the joiner work. With the Trim/Cribbage piece install flush with the enclosure door, it shall allow the door to open at least 150 degrees. Meters: Two meters shall be provided. One for Voltage 0-30 Vdc (FS) and one for amperage 0-100 ADC (FS). Bus: Copper 250 Amp @ 415 VDC. Circuit Breakers: Standard thermal-magnetic circuit breakers. UL 1077 Listed. IEC B98 Type Approval. Interrupting capacity range of 14kA @ 120/240 VAC to 5kA @ 480 VAC, DC rating of 55V per pole, ambient temperature range of -25? C to +45?C. Shock resistant rating of 30g half sine shock load @ 6ms, and a vibration resistance rating of ? 6g. Selectable trip curves. The number of breakers, breaker trip ratings and number of polls required shall be as shown on the faceplate legend attached. Internal construction: The main breaker shall break both line side feeders. Line side bus bar connected circuit breakers. DIN rail mounted components. All connections and bus work shall be insulated. The connection at the negative side of the terminal blocks shall be sized large enough to accept a # 2 awg cable. The Voltmeter and Ammeter shall be located at the top of the panel. Quick disconnect electrical fittings shall be installed with the faceplate mounted meters so the faceplate can be completely detached from the enclosure easily. The connections shall be indexed so that the cables for the appropriate meter will only connect to that meter. Custom high-strength polycarbonate faceplate that doubles as a captive device for circuit breakers under high shock conditions. Faceplate shall be black with engraved circuit descriptions in white. Circuit arrangement shall be as shown on the faceplate legend attached. International Marine Products, Inc., Panel board Model Number: PS-DC-32-41 or Equal will meet these requirements. It is the Government's belief that only International Marine Products or their authorized dealers can provide these supplies/services. However, other potential sources with the expertise and required capabilities to submit such supplies can submit such data discussing the same in duplicate within 7 days from the date of this announcement to skmiller@elcbalt.uscg.mil or fax to 410 636-7458, Attn: Mrs. Sandy Miller. The following information must be provided to evaluate the acceptability of the offered services: (1) data that the panel boards have been satisfactorily offered to the public or the Government in the past. These panel board will be installed on the U. S. Coast Guard 41? UTB?s. This data must include sufficient information to allow the Coast Guard to evaluate the quotes IAW the above requirements. No cost or pricing is required. THIS IS NOT A SOLICITATION. THIS IS A REQUEST FOR INFORMATION ONLY. This synopsis is issued pursuant to FAR 5.207(e)(3). The NAICS Code for this requirement is 335313; and the supplies are considered to be commercial.
 
Record
SN00322815-W 20030515/030513213136 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers