70 -- Generator

Notice Date
11/20/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Defense Information Systems Agency, Acquisition Directorate, DITCO-Scott, 2300 East Drive Bldg 3600, Scott AFB, IL, 62225-5406
 
ZIP Code
62225-5406
 
Solicitation Number
ADP0027
 
Archive Date
12/20/2002
 
Point of Contact
Linda Eley , Contract Specialist, Phone 618-229-9736, Fax 618-229-9440, - Linda Eley , Contract Specialist, Phone 618-229-9736, Fax 618-229-9440,
 
E-Mail Address
eleyl@scott.disa.mil, eleyl@scott.disa.mil
 
Description
Please provide a quote for the following specifications: Generator Set (Quantity 1) 50DGHE Genset-Cummins 3.3L Diesel Engine, 60Hz, 50kW 1 A331-2 Duty Rating-Standby Power 1 L090-2 LISTING-UL 2200 1 L060-2 Certification-EPA, Tier 1, Non Road 1 F182-2 Housing-Weather w/muffler 1 R002-2 Voltage-277/480, 3 Phase Wye 1 B268-2 Alternator-60Hz, 12 Lead, Broad Range, 105c Temperature Rise 1 H559-2 Set Control-Detector 12, With Ac Meters 1 Detector 12 Control System o Automatic remote starting o Control components designed to withstand the vibration levels typical in generator sets o Controls generator set starting and shutdown Standard Detector 12 Light (NFPA 110) Control Description o 12 light engine monitor (NFPA110 level) o Common alarm contact o Coolant temperature gauge o Cycle cranking control o DC Voltmeter o Field circuit breaker o Individual 1/2 A relay signals o Lamp test switch o Oil pressure gauge o Remote starting, 12 V, 2 wire o Reset switch o Run-Off-Auto switch o Running time meter Standard Features o 5% voltage adjust rheostat o AC ammeter (dual scale) o AC voltmeter (dual scale) o Dual scale frequency/tachometer o Engine gauges o High coolant temp shutdown (red light) o Low coolant temperature (yellow light) o Low fuel (yellow light) o Low oil pressure shutdown (red light) o Overcrank shutdown (red light) o Overspeed shutdown (red light) Item Description (QUANTITY 1) o Pre-alarm high coolant temp (yellow light) o Pre-alarm low oil pressure (yellow light) o Run indicator (green light) o Two customer selected faults (red light) o Voltmeter/Ammeter phase selector B184-2 Exciter/Regulator-PMG, 3 Phase Sensor 1 This option uses an integral PMG to supply power to the voltage regulator. A PMG system generally has better motor starting performance, lower voltage dip upon load application, and better immunity from problems with harmonics in the main alternator output induced by non-linear loads. This option is recommended for use in applications that have large transient loads, sensitive electronic loads (especially UPS applications), harmonic content, or that require sustained short-circuit current (sustained 3-phase short circuit current at approximately 3 times rated for 10 seconds). A366-2 Engine Governor-Electronic, Isochronous Only 1 Electronic governing is available for applications requiring constant (isochronous) frequency regulation such as Uninterruptible Power Supply systems, non-linear loads, or sensitive electronic loads. H543-2 Warning-Low Battery Voltage 1 KL39-2 Control Package-Start/Stop Delay, Emergecny Shutdown, Audible Alarm 1 H536-2 Display Language-English 1 KM65-2 Circuit Breaker Mounting-Single Breaker, Left Of Control 1 C168-2 Fuel Tank-Dual Wall Subbase, 24 Hour Capacity (140 gallon) or 12 Hour (70 gallon) 1 Sub Base Fuel Tank Features: o UL 142 Listed o Double Wall Leak Containment Design o Emergency pressure relief vent cap o Atmospheric vent cap o Raised fuel fill o Fuel level gauge o Low Fuel level switch-Factory set at 50% level o Leak detection switch o Removable end panel/channel C157-2 Switch-Low Fuel Level, Subbase 1 C169-2 Switch-Annunciator, Liquid In Rupture Basin 1 F179-2 Skidbase-Housing Ready 1 E074-2 Engine Cooling-Radiator, 50c Ambient 1 H036-2 Coolant Heater-120 Volt Ac, Single Phase 1 L028-2 Warranty-1 Year Base 1 A322-2 Packing-Skid, Poly Bag 1 F065-2 Rack-Battery 1 SPEC-A Product Revision - A 1 H389-2 Shutdown-Low Coolant Level 1 E089-2 Extension-Engine Coolant Drain 1 F180-2 Window-Enclosure,Control Viewing 1 H268-2 Extension-Oil Drain 1 Submittals Installation Documents 6 Initial Fill Coolant & Lubricant 1 Start-Up System Check & Inspection 1 Battery - SAE 31 12 Volt, Lead Acid 1 Manual Maintenance, Operations, Installation & Parts 4 Walk Through 4 Hours of System Instruction for Site Personnel 1 Delivery FOB Job Site 1 Mileage Travel Time to and from Job Site 1 Electrical Installation Terminate Load Wires of New Genset & ATS 1 Removal of existing genset Disconnect old ONAN genset and remove from location 1 Transfer Switch (QUANTITY 1) OTPC125 Transfer Switch-Onan, PowerCommand, 125 Amp 1 A028-7 Poles-3 1 A035-7 Application-Utility To Genset 1 A046-7 Listing-UL 1008/CSA Certification 1 A044-7 Frequency-60 Hertz 1 A042-7 System-3 Phase,3 Wire Or 4 Wire 1 R026-7 Voltage-480 Vac 1 B001-7 Cabinet-Type 1 1 C024-7 Switch Control-Level 2 1 Software Adjustable Time Delays: Engine Start: 0 - 120 sec Transfer Normal to Emergency: 0 - 120 sec Retransfer Emergency to Normal: 0 - 30 min Engine Stop: 0 - 30 min Programmed Transition: 0 - 60 sec Over/Undervoltage Sensing - 3-phase normal and emergency Pickup: 85% to 98% of nominal voltage Dropout: 75% to 98% of pickup setting Dropout Time Delay: 0.1 to 1.0 sec Overvoltage Sensing - 3-phase normal and emergency Dropout: 105% to 135% of nominal voltage Pickup: 95% to 99% of dropout setting Dropout Time Delay: 0.5 to 120 sec Frequency Sensing Pickup: ? 5 % to ? 20% of nominal frequency Dropout: ? 1% beyond pickup Dropout Time Delay: 0.1 to 15.0 sec Voltage Imbalance Sensing Dropout: 2% to 10% Pickup: 90% of dropout Time Delay: 2.0 to 20.0 sec Phase Rotation Sensing Time Delay: 100 msec Loss of Single Phase Detection Time Delay: 100 msec Standard Open Transition Transfer Mode Programmed Transition Transfer Mode Programmable Genset Exerciser - Eight events/schedules Basic Indicator Panel Source Available/Connected LED Indicators Test/Exercise/Bypass Buttons Digital Display Date/Time-Stamped Event Recording M018-7 Display-Digital 1 The digital display provides a convenient method for monitoring load power conditions, adjusting transfer switch parameters, monitoring PowerCommand Network status, or reviewing transfer switch events. Password protection limits access to adjustments to authorized personnel K001-7 Battery Charger-2 Amp,12/24 Vdc 1 SPEC-A Product Revision - A 1 Grand Total installed & started up SHIP TO ADDRESS: Fort Sill Commissary Building 1719 1719 Macomb Road Fort Sill OK 73503-7400 If you have any questions please email at eleyl@scott.disa.mil or call Linda Eley at 618-229-9736
 
Place of Performance
Address: SHIP TO ADDRESS:, , Fort Sill Commissary, Building 1719, 1719 Macomb Road, Fort Sill OK 73503-7400, ,
Country: UNITED STATES
 
Record
SN00207841-W 20021122/021120213017 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.