Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 18, 2002 FBO #0320
SOURCES SOUGHT

61 -- Gas-Blocked, 1/2-inch, 50-ohm foam dielectric, smooth outer conductor, coaxial cable

Notice Date
10/16/2002
 
Notice Type
Sources Sought
 
Contracting Office
Department of Energy, Bechtel Nevada Corp (DOE Contractor), Bechtel Nevada, PO Box 98521, Las Vegas, NV, 89193
 
ZIP Code
89193
 
Solicitation Number
200301-EF-03
 
Archive Date
11/7/2003
 
Point of Contact
Emma Fox, Senior Procurement Specialist, Phone 702.295.0507, Fax 702.295-3109, - Dennis Jeffrey, Senior Procurement Specialist, Phone 702-295-2192, Fax 702-295-3109,
 
E-Mail Address
foxeb@nv.doe.gov, jeffredj@nv.doe.gov
 
Description
Bechtel Nevada is seeking sources that can provide the following item to include certification that it meets the following requirements: GAS-BLOCKED 1/2-INCH 50-OHM FOAM DIELECTRIC SMOOTH OUTER CONDUCTOR COAXIAL CABLE GENERAL. DESCRIPTION: A 1/2 -inch, 54-ohm coaxial cable, consisting of a solid bare copper center conductor, foamed polyethylene dielectric, smooth wall aluminum outer conductor, and an outer jacket of white polyolefin. This cable is gas-blocked completely by using selected materials and sealant materials as required to gas-block the cable. DIMENSIONS: Finished Cable O.D.: 0.650-inch, Max. Inner conductor O.D.: 0.179 inch. Outer conductor O.D.: 0.500 inch. APPLICATION: Transmission of fast rise-time electric pulse and withstanding the following range of environmental conditions: Temperature: Flexing (Installation and Operation): -20F to +165F Open-End Gas pressure, without leaking after Bending and Temperature Cycling: 125 psig, Min. REQUIREMENTS: Electrical: Characteristic Impedance: 50.0 ohm, Max. Velocity of Propagation: 77%, Min, Attenuation vs. Frequency in dB/1000 ft: 10 MHz 2.8 Max. 100 M11z 9.1 Max. 1000 MHz 35.0 Max. 2000 MHz 54,0 Max. 3000 MHz 71.0 Max. Pulse Reflection (Time Domain Reflectometer): 1% Max. of incident pulse amplitude. de Resistance per 1000 ft:Inner Conductor: 0.65 ohm, Max. Outer Conductor: 0.75 ohm, Max. de Voltage Withstand and Leakage Current: 15kVdc. Mechanical: Bend Radius: No less than 6.0 inches Tension: 600 lbs. Interested parties provide a narrative of capabilities and/or product data to Emma Fox at fax number (702) 295-9106. Other items to include are business size and point of contact information to include email address. Provide responses no later than October 24, 2002.
 
Record
SN00188787-W 20021018/021016213245 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.