SOLICITATION NOTICE

61 -- EMERGENCY GENERATORS

Notice Date
8/9/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC NORFOLK HAMPTON ROADS, ACQUISITION DEPT, CODE 200 1968 GILBERT STREET, SUITE 600, NORFOLK, VA, 23511-3392
 
ZIP Code
23511-3392
 
Solicitation Number
N00189-02-T-0967
 
Response Due
8/26/2002
 
Point of Contact
Linda Mathews, Purchasing Agent, Phone 757-443-1329, Fax 757-443-1389,
 
E-Mail Address
linda_a_mathews@nor.fisc.navy.mil
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format prescribed in Subpart 12.6 of the FAR, as supplemented with additional information included in this notice. This announcement constitutes the request for quote for the required items. Request for Quotes are hereby requested under RFQ N00189-02-T-0967, a subsequent solicitation document will not be issued. Acquisition Department at FISC Norfolk intends to purchase on a full and open competitive all or none basis the following items: Clin 0001: Emergency Generator 25 KW. General Specifications: Standard FFP - 33 GL fuel tank, standard auto/remote start module, hour meter, voltage & hertz led indicators, muffler, vibration isolators installed, battery/battery rack and cables, manuals for engine and generator. Engine Specifications: Daewoo DB 24, Type: 4 cycle water cooled, 1800 RPM, Rated Output: 34 PSI, Cylinder Bore Stroke: 86 x 104 mm, Displacement: 2.389 liters, Compression Ratio: 20 to 1, Fuel Consumption: 7.5 liters/hour, Fuel Injection Pump: Bosch Type "A", Governor: Mechanical 5%, Cooling: Blower type steel blades, Lube Cap: 5 liters, Cooling Water Cap: 5.2 liters, Charging Alternator: 12 V / 61 A, Starting Motor: 12 V / 2.2 KW. Generator Specifications: Stanford Newage, normally built in 1 phase 240 / 120 V 60 HZ, 3 phase generators at no extra charge, flexible disc coupling, self-exciting and self-regulating, drip proof alternator, BS5000 norms with class "H" insulation, Voltage regulation: 1.5%. Length: 72 inches, Width: 32 inches, Height: 54 inches, Weight: 1300 lbs. Clin 0002: Emergency Generator 150D. General Specifications: Daewoo FFP - powered generator set with newage generators, standard 90 GL fuel tank, standard auto/remote start module, full instrumentation, full engine safety shutdowns, muffler vibration isolators installed, battery/battery rack and cables, 120 VAC water jacker heater, full set of manuals for engine and generator. Engine Specifications: Daewoo Engine D1146T, Type: 4 cycle water cooled, turbo charged, 1800 RPM, Rated Output: 187 PSI, Cylinder Bore Stroke: 6-111 x 139 mm, Displacement: 8,071 liters, Compression Ratio: 17.5 to 1, Fuel Consumption: <>26.9 liters/hour, Fuel Injection Pump: Zexel type steel blades (6), Lube Cap: 15.5 liters, Cooling Water Cap: 14.4 liters, Charging Alternator: 24V / 45A, Starting Motor: 24V / 45 KW. Generator Specifications: Newage generator, Phase: 208/120V 60 HZ, flexible disc coupling, self-exciting and self-regulating, drip proof alternator, Class "H" insulation, Voltage regulation: 1.5%. Length: 80 inches, Width: 32 inches, Height: 54 inches, Weight: 2250 lbs. Clin 0003: Emergency Generator D 60 KW. General Specifications: Daewoo FFP - powered generator set with newage generators, standard 60 GL fuel tank, standard auto/remote start module, full instrumentation, full engine safety shutdowns, muffler vibration isolators installed, battery/battery rack and cables, full set of manuals for engine and generator. Engine Specifications: Daewoo DB 58, Type: 4 cycle water cooled, naturally aspirated, 1800 RPM, Rated Output: 95 PSI, Cylinder Bore Stroke: 6-102 x 118 mm, Displacement: 5.785 liters, Compression Ratio: 17.5 to 1, Fuel Consumption: <>18.8 liters/hour, Fuel Injection Pump: Zexel Type "A", Governor: Mechanical 5%, Cooling: Blower type steel blades, Lube Cap: 19 liters, Cooling Water Cap: 12 liters, Charging Alternator: 24V/45A, Starting Motor: 24V/4.5 KW. Generator Specifications: Newage generator, normally built 1 phase 240/120V 60 HZ or 3 phase multi-volt configuration, flexible disc coupling, self-exciting and self-regulating, drip proof alternator, Class "H" insulation, Voltage regulation: 1.5%. Length: 72 inches, Width: 32 inches, Height: 54 inches, Weight: 1300 lbs. FOB Point: Destination to Norfolk, VA. The following FAR provisions and clauses apply to this solicitation and are incorporated by reference: FAR 52.212-1 Instructions to Offerors-Commercial Items (OCT 2000), FAR 52.212-3 Offeror Representations and Certifications-Commercial Items (MAY 2001) ALTERNATE I (OCT 2000), FAR 52.212-4 Contract Terms and Conditions-Commercial Items (MAY 2001), FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes or Executive Orders (MAY 2001) within this clause, the following clauses apply; 52.222-21 Prohibition of Segregated Facilities (FEB 1999), 52.222-26 Equal Opportunity (E.O. 11246), 52.222-35 Affirmative Action for Disabled Veterans and Vietnam Era (38 U.S.C. 4212), 52.222-36 Affirmative Action for Workers with Disabilities (29 U.S.C. 793), 52.222-37 Employment Reports on Disabled Veterans and Veterans of the Vietnam Era (38 U.S.C. 4212), 52.222-19 Child Labor--Cooperation with Authorities and Remedies (E.O. 13126), 52.225-13 Restriction on Certain Foreign Purchases (E.O. 12722, 12724, 13059, 13067, 13121, and 13129), 52.232-33 Payment by Electronic Funds Transfer --Central Contractor Registration (31 U.S.C. 3332),FAR 52.215-5 Facsimile Proposals (OCT 1997). The RFQ document, (N00189-02-T-0569), provisions and clauses, which have been incorporated, are those in effect through FAC 97-27. The following Defense FAR Supplement (DFAR) provisions and clauses apply to this solicitation and are incorporated by reference, with the exception of DFAR 252.204-7004 which will be in full text, DFAR 252.212-7001 Contract Terms And Conditions Required To Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (DEC 2000) within this clause the following clauses applies; DFAR 252.225-7001 Buy American Act and Balance of Payments Program (41 U.S.C. 10a-10d, E.O. 10582), DFAR 252.225-7000 Buy American Act--Balance Of Payments Program Certificate (SEP 1999),DFAR 252-204-7004 Required Central Contractor Registration (MAR 2000); (a) Definitions. As used in this clause ? (1) ?Central Contractor Registration (CCR) database? means the primary DOD repository for contractor information required for the conduct of business with DOD. (2) ?Data Universal Numbering System (DUNS) number? means the 9-digit number assigned by Dun and Bradstreet Information Services to identify unique business entities. (3) ?Data Universal Numbering System +4 (Duns+4) number? means the Duns number assigned by Dun and Bradstreet plus a 4-digit suffix that may be assigned by a parent (controlling) business concern. This 4 digit suffix may be assigned at the discretion of the parent business concern for such purposes as identifying subunits or affiliates of the parent business concern. (4) ?Registered in the CCR database? means that all mandatory information, including the DUNS number or the Duns +4 number, if applicable, and the corresponding Commercial and Government Entity (CAGE) code, is in the CCR database; the DUNS number and the CAGE code have been validated; and all edits have been successfully completed. (b) (1) By submission of an offer, the offeror acknowledges the requirement that a prospective awardee must be registered in the CCR database prior to award, during performance, and through final payment of any contract resulting from this solicitation, except for awards to foreign vendors for work to be performed outside the United States. (5) The offeror shall provide its DUNS or, if applicable, its DUNS +4 number with its offer, which will be used by the Contracting Officer to verify that the offeror is registered in the CCR database. (6) Lack of registration in the CCR database will make an offeror ineligible for award. (7) DOD has established a goal of registering an applicant in the CCR database within 48 hours after receipt of a complete and accurate application via the Internet. However, registration of an applicant submitting an application through a method other than the Internet may take up to 30 days. Therefore, offerors that are not registered should consider applying for registration immediately upon receipt of this solicitation. (c) The contractor is responsible for the accuracy and completeness of the data within the CCR, and for any liability resulting from the Government?s reliance on inaccurate or incomplete data. To remain registered in the CCR database after the initial registration, the contractor is required to confirm on an annual basis that its information in the CCR database is accurate and complete. (d) Offerors and contractors may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423, or via the Internet at http: //www.ccr.dlsc.dla.mil, At a minimum, responsible sources should provide this office: a price proposal on letterhead or a SF1449 for the requested item, with unit price, extended price, prompt payment terms, remittance address, Tax I.D. #, Duns #, Cage code, and a completed copy of FAR 52.212-3. Responses to this solicitation are due by 26 August 2002 4:30 PM EST. Offers can be faxed to (757-443-1376) or mailed to; Acquisition Department, Fleet & Industrial Supply Center, 1968 Gilbert St., Suite 600, Attn: T. Tobias Code 202C, Norfolk, VA 23511-3392. Reference RFQ N00189-02-T-0967, on your proposal. Questions may be directed to T. Tobias at (757) 443-1425. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (09-AUG-2002). IT ACTUALLY FIRST APPEARED ON THE FEDBIZOPPS SYSTEM ON 30-SEP-2002. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.eps.gov/spg/USN/NAVSUP/N00189/N00189-02-T-0967/listing.html)
 
Place of Performance
Address: VREP CONTRACTORS NAVAL AIR STATION BLDG. LP-117 8349 AIR CARGO RD. NORFOLK, VA
Zip Code: 23511-4496
Country: USA
 
Record
SN00179003-F 20021002/020930215917 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.