Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 16, 2002 FBO #0288
SOLICITATION NOTICE

52 -- Temperature/Humidity Measuring Tools

Notice Date
9/13/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, CA, 93524-1185
 
ZIP Code
93524-1185
 
Solicitation Number
Reference-Number-F1EWWX22210200
 
Point of Contact
Philip Cheng, Contract Negotiator, Phone 661-277-8658, Fax 661-277-0473,
 
E-Mail Address
philip.cheng@edwards.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared IAW the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested and a written solicitation will not be issued. This is a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 97-27 and DFARs Change Notice (DCN) 20001213. Simplified Acquisition Procedures (The award will be less than $100,000) will be followed. Standard Industrial Classification (SIC) code is 3829. Small business size standard is 500. NAICS is 334519. This acquisition is a 100% small business set aside. The Air Force Flight Test Center (AFFTC) is seeking sources for the anticipated purchase of the following items. Four (4) -20 to +120 deg F, 7 day 4" temperature chart reports with digital display, Four (4) 4" chart, -20 to +120 deg F, 7 day charts for SL4120F7, Four (4) Carrying cases, 5", nylon material with loops and hoops to hold charts, Four (4) Temperature, pressure, universal, input, event replacement pens, -6 Red color, Five (5) Remote sensing temperature, humidity, and dew point recorder, -8" chart, Specifications Follow: Humidity Accuracy: ?2% from 0 to 60%, ?3% from 60 to 95%, Humidity Range: 0 to 95% (non-condensing), Humidity Sensor: Monolithic IC Humidity Sensor, Temperature Accuracy: ?1.8?F (?1?C), Temperature Ranges: User selectable; -20 to +120?F, +40 to +110?F, -20 to +50?C, +5 to +40?C, Temperature Sensor: Thermistor Alarms: Audio/Visual with High/Low set points (warning mechanism only, no controller function) Alarm is 90 decibels, Ambient Operating Conditions: 0 to 95% RH (non-condensing), +32 to +122?F (0 to +50?C), Calculated Dew Point Accuracy: The Dew point is calculated and because of the nonlinearity of the equation the error that would result from the possible errors of temperature and relative humidity are approximately as follows: 95% to 30% RH = ? 2?C, ?3.6?F; 30% to 10% RH = ?4?C, ?7.2?F; 10% to 5% RH = ?8?C, ?14.4?F; 5% to 0% RH = ?49?C, ?88.2?F, Calculated Dew Point Range: -22 to +122?F, -30 to +50?C, Average Response Times: 2.5 min at 63% of full scale Note: The THDx internally averages readings together. In battery mode the update rate is slowed to conserve power and since the unit takes 1 new reading per update, the response is also slowed. Battery power is recommended for back-up only., Average Battery Life: 1 day recording mode = 2 months, 7 day = 3 months, 31 day = 4 months, Calibration: User calibration, see calibration kit below, Calibration Kit (optional): 12% (RH only-low end capsule) and 75% (high-end capsule 75% salt solution) 1 year shelf life, MSDS (material safety data sheet) available upon request, Chart Size: 8" diameter Dimensions: 10.5" x 13.2" x 2.8" (26.7cm x 33.5cm x 7.1cm), Display Resolution: 1?F (1?C), 1% RH, Display Type: LCD, Mounting: Free standing or keyhole for wall mount, Pen Life: 12 months depending on use, Power Supply: 120V AC adapter, use 4 "D" batteries for back-up power. Power Cord Length: 2 meters, Probe Dimensions: .91" diameter, 5.9" long (15.0 cm x 2.3 cm dia) 10" cord - RJ11 6 pin connector, Recording Times: User selectable; 1, 7, and 31 day, Warm Up Time: 15 minutes to stabilize Warranty: 1 year, Enclosure Type & Weight: ABSWeight: 5 lbs without batteries (1.5 kg), 7 lbs with batteries (3.2 kg), Approvals: CE, Includes: 1-point NIST Traceable Certificate of Calibration, two Pens, Box of 60 (-20 to +120/7 day) Charts, AC adapter, and Instructions, Five (5) 8" charts, -20 to +120 deg, 7 day (0 to 100 RH) charts for THDX, Five (5) 10' (3.05 m) Probe extension cables for THDX Probe, Five (5) Replacement pens -3 Red, 3 Blue (Temperature and Humidity) for THDX, Six (6) Flat panel LCD Recorder with Internal Temperature and Humidity sensors, Three (3) NIST Traceable Calibration 3-pt, Two (2) 4" Digital Moisture Meter (Digital Readout: N/A, Three Scales: N/A, Wood Scale: 6% to 40% moisture range. Use for flooring and building material such as wood studs, floor joist, subfloors and external siding, Reference Scale: 0 to 100 on a relative basis. Use on non-wood materials such as concrete, plaster, EIFS, roofing and insulation, Gypsum Scale: .2% to 6% moisture range. Use on sheetrock, Specifications: Three Scales: ? Wood Scale - 6% to 40% Moisture Range ? Gypsum Scale - 0.2% to 6% Moisture Range ? Reference Scale - 0 to 100 on a relative basis Digital Readout: LCD Power Supply: 9V Battery Dimensions: 8" x 3" x 1.5" (20 x 7.6 x 3.8 cm) Weight: 9.93 oz (281 g) Features: Stores up to 50 accumulated readings; Set-point alerts you when a pre-selected moisture content is reached., Two (2) Extension probe: 3.25" pins on a 4" extension cable for EIFS Inspection for model D190, Two (2) Non- contact infrared indicator with 8 pt. laser sighting -50:1 field of view, One (1) Non- contact infrared indicator with data logging and 16 pt. laser sighting -60:1 field of view: Specifications, Type: Pistol Grip Field of View: 50:1 Laser Sighting: 8 pt. Circular Temperature Range: -25 to +1400?F (-32 to +760?C) Accuracy: 1% or ?2?F (?1?C), whichever is greater above 73?F (23?C); ?3?F (?2?C), from 0 to +73?F (-18 to +23?C); ?4?F (?2.5?C), from -15 to 0?F (-26 to -18?C); ?5?F (?3?C), from -25 to -15?F (-32 to -26?C) Repeatability: <?0.5% or <?2?F (?1?C) whichever is greater Response Time: <0.5 second (95% of reading) Ambient Operating Range: 32 to 120?F (0 to 50?C) Power: 9V Battery Emissivity: User adjustable Data Logging: 12 points Display Hold: 7 seconds Alarm: Hi/Low Display Resolution: 0.1?F/C ), One (1) Vantage Pro Wireless Weather Station (Required features include: data logging and precise 16-point coaxial laser sighting, Fahrenheit/Celsius Switchable, Quick Response Time (250 mSec, 95% response) and Adjustable Emissivity Large Digital Display Featuring a Bar Graph of the Last 10 Temperature Points Measured. Specifications: Type: Pistol Grip Field of View: 60:1 Laser Sighting: 16 pt. Circular Temperature Range: -25 to +1600?F (-32 to +760?C) Accuracy: .75% or ?2?F, (?1?C), whichever is greaterRepeatability: <?0.5% or <?2?F (?1?C) whichever is greater Response Time: <0.25 second (95% of reading) Ambient Operating Range: 32 to 120?F (0 to 50?C) Power: 2 AA Batteries/AC Adapter Emissivity: Adjustable Data Logging: 100 points Display Hold: 7 seconds Alarm: Hi/Low Display Resolution: 0.1?F/C Includes: Windows based data logging software, download cable, K Thermocouple probe, plug-in power supply, hard-shell carrying case, 2 "AA" batteries, One (1) Moisture sensor for D462 Specifications Display: LCD 3 1/2" x 6"Power: AC-Power Adapter / 3 C Batteries (1 yr. life)Wireless Range: Up to 400? line of site, Typical 100? to 200?Includes: Console/Receiver, integrated sensor suite with transmitter, solar panel, 40? anemometer cable, mounting hardware, AC Adapter and instructions Variable Resolution Range Accuracy Barometric Pressure: 0.01" Hg 26" to 32" Hg +/- 0.05" Hg Evapo- transpiration: Solar Radiation Sensor Required 0.01" Daily to 99.99; Monthly & Yearly to 199.99 +/- 5% Humidity & Dew Point: Inside Humidity 1% 10 to 90% +/- 5% RH Outside Humidity 1% 0 to 100% +/- 3% RH Dew Point 1 deg F -105 to +130F +/- 3 deg F Rainfall: .01" Daily 0 to 99.99"; Mo. & Yr. to 199.99 +/- 4% Rain Rate: .01" Up to 100"/hr. +/- 5% Soil Moisture: Soil Moisture Station Required 1cb 0 to 200 cb Temperature: Inside Temp 0.1 deg F +32 to 140 F +/- 1deg F Outside Temp 0.1 deg F -40 to 140 F +/- 1 deg F Heat Index 1 deg F -40 to 135F +/- 3 deg F Wind: Direction 1 deg 0 to 360 deg +/- 7 deg Compass Rose 22.5 deg 16 compass pts +/- 0.3 comp pt Wind Speed 1 mph 3 to 175 mph +/- 2 mph Wind Chill 1 deg F -120 to 130 F +/-4 deg F One (1) Temperature sensor for D462 One (1) Wireless temperature humidity station for D460 For additional information, please contact the Buyer at Philip.cheng@edwards.af.mil or 661-277-8658. Interested parties who believe they can meet all the requirements for the all of the items described in this synopsis are invited to submit in writing complete information describing their ability to provide the required equipment. FOB Destination is the Government preferred method of shipping. Please submit FOB Destination shipping information with all submittals to the office. Offerors are required to submit with their quote enough information for the Government to evaluate the minimum requirements detailed in this synopsis. CONTRACTORS MUST COMPLY WITH DFARS 252.204-7004, REQUIRED CENTRAL CONTRACTOR REGISTRATION (MAR 2000). INTERESTED CONTRACTORS CAN ACCESS THIS CLAUSE BY INTERNET URL: http://farsite.hill.af.mil. TO REGISTER WITH THE CCR, GO TO URL: https://www.ccr.dlsc.dla.mil/. The following provisions and clauses apply: Provision 52.252-1 Solicitation Provisions Incorporated by Reference. This solicitation incorporates one or more solicitation provisions by reference, with the same force and effect as if they were given in full text. Upon request, the Contracting Officer will make their full text available. Provision 52.212-1, Instructions to Offerors--Commercial; clause 52.212-4, Contract Terms and Conditions--Commercial Items; clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders--Commercial Items (to include: 52.222-26, Equal Opportunity; 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans; 52.222-36, Affirmative Action for Handicapped Workers; 52.222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era); clause 52.232-33 Mandatory information for electronic funds transfer payment. Offerors must include a completed copy of the provision 52.212-3, Offeror Representations and Certifications--Commercial Items with the offer. If the offeror does not have a copy of this provision, a copy can be downloaded from this website: http://farsite.hill.af.mil. The following DFARs clauses apply to this acquisition: Clause 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisition of Commercial Items (Mar 1998); 252.225-7001 Buy American Act and Balance of Payment Program; clause 252.225-7036, North American Free Trade Agreement Implement Act. Offers are due at the Air Force Flight Test Center, Directorate of Contracting, 5 South Wolfe Avenue, Edwards AFB, CA, 93524, not later than Close of Business (COB) 27 Sep 2002 at 4 pm. Faxed transmissions of quotes are acceptable. Fax #: 661-275-7827 or e-mail address: Philip.cheng@edwards.af.mil. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS.GOV ON THE DATE INDICATED IN THE NOTICE ITSELF (13-SEP-2002). IT ACTUALLY FIRST APPEARED ON THE FEDBIZOPPS SYSTEM ON 14-SEP-2002. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Place of Performance
Address: 5 S. Wolfe, Edwards AFB, CA
Zip Code: 93524
Country: USA
 
Record
SN00166990-W 20020916/020914214201 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.