58 -- Explosive Destruction System (EDS) Phase II Vapor Containment System (VCS)consisting of a steel arch structure, a Negative Air Filter (NAF) Unit, associated ductwork and electrical controls.

Notice Date
9/10/2002
 
Notice Type
Solicitation Notice
 
Contracting Office
US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch, ATTN: AMSSB-ACC-A, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
 
ZIP Code
21005-3013
 
Solicitation Number
W91B94-2240-0018
 
Point of Contact
Jo Ann Hayes, 410-278-0771
 
E-Mail Address
Email your questions to US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch
(jo.hayes@sbccom.apgea.army.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
NA This is a combined synopsis/soliciation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. The U.S. Army Robert Morris Acquisition Center intends to solicit Air Cleaning Technologies, Inc., 10615 Judicial Drive, Fairfax, VA 22030 to acquire the supplies and equipment necessary to procure an Explosive Destruction System (EDS) Phase II Vapor Containment System (VCS). The EDS VCS shall consist of a Steel Arch Struc ture, a Negative Air er (NAF) Unit, associated ductwork, and electrical controls. The steel structure shall be nominally 30 feet wide by 60 feet long with a height of 17 feet at the center. The NAF Unit shall include an inlet damper, transition, pre-filte r section, HEPA filter Section #1, MINICAM (Chemical Agent Monitor) sample port section #1, carbon filter section #1, MINICAM sample port section #2, carbon filter section #2, MINICAM sample port section #3, HEPA filter section #2, transition, outlet dampe r, and fan set. The entire assembly shall be skid mounted, designed for a low profile, minimum size and minimum weight, and be configured for ease of transportation by a prime mover for field use. The NAF Unit shall be sized for 6000 cfm operation. The unit specified in this document shall not exceed 25 feet in length, 96 inches in height and 81 inches in width. For complete specifications, drawings, and submittal information, please contact the contract specialist listed below. Reference Number W91B94 22400018. This is an urgent requirement. The delivery of this equipment impacts on a contract with DSTL in the UK. Equipment is needed in order to support testing of the EDS Phase II in Porton Down, UK. Air Cleaning Technologies, Inc. is being solicited pursuant to 10 U.S.C. 2304(c)(1) (FAR Part 6.302-1), Only one responsible source and no other supplies or services will satisfy agency requirements. The EDS VCS system requires specialized integration of several components for which Air Cleaning Technolo gies, Inc. has the required experience and expertise necessary to integrate the various components. A search for alternate vendors was sought for these services yielding no viable candidates. This combined synopsis/solicitation will close 18 September 20 02. See note 22.
 
Place of Performance
Address: US Army Robert Morris Acquisition Center, APG Contracting Div., Aberdeen Branch ATTN: AMSSB-ACC-A, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
Zip Code: 21005-3013
Country: US
 
Record
SN00162547-W 20020912/020910213712 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.