MODIFICATION

48 -- High Pressure Actuated Ball Valves

Notice Date
4/17/2002
 
Notice Type
Modification
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, CA, 93524-1180
 
ZIP Code
93524-1180
 
Solicitation Number
F04700-02-T-0030
 
Response Due
4/19/2002
 
Archive Date
5/31/2002
 
Point of Contact
Lesley Ervan, Contract Specialist, Phone 661-277-7706, Fax 661-275-7809, - Nicasio Arabe, Contract Negotiator, Phone 661-277-3321, Fax 661-275-7884,
 
E-Mail Address
lesley.ervan@edwards.af.mil, nicasio.arabe@edwards.af.mil
 
Description
The reason for this amendment is to address a question raised concerning the actuation specifications. The question, response and a change in the specifications is identified below: Question: Regarding the actuation, it appears that a direct acting actuator with an overall length dimension of approximately 49" is essential due to size contraints. This actuator will require an accumulation tank and dump valves, tubing etc. Will Edwards be taking care of the accumulation tank and assorted valve and tubing or would you prefer the contractor to quote the tank and accessories as well as the actuator. For complete testing, the tank is necessary. Response: After reevaluating the size and type of actuator, the following changes to the original specification are made: 1. The overall size of the actuator shall be no longer than 50" and the overall diameter shall be no greater than 25". The actuator shall be oriented lengthwise along the valve body. 2. The vendor may substiture a pneumatic actuator in place of the hydraulic actuator specified provided it meets the same functional and operational requirements, and the spatial requirements identified in item 1 above. The Contracting Officer has up to 1500 psi GN2 available to operate the actuator. 3. If the vendor elects to provide a pneumatic actuator then the vendor shall be responsible to provide a GN2 accumlator as well. The accumulator shall be pressure rated at least 20% greater than the design actuation pressure. It shall be sized such that it can open and close the ball valve three complete cycles without recharging. The accumlator shall be designed, fabricated and stamped in accordance with ASME Section VIII, Division 1. The inlet/outlet connection shall be either an MS 33649 straight thread or FNPT. The connection shall be sized to accommodate the required flow. The accumlator be lined with either baked on phenolic resin, electrodeless nickel plating or epoxy coating. All supporting documentation for the acculator required by the ASME code shall be provided. 4. The vendor may use the accumulator for shop testing of the valve to verify proper actuation and operation. After testing the accumlator shall be cleaned to level 300 of MIL-STD-1246C, and the openings shall be plugged or otherwise protected for shipment. 5. All interconnecting tubing between the accumulator and valve actuator required for shop testing only shall be furnished by the vendor. The Contracting Officer shall supply all interconnecting tubing, valves, filters, etc. for permanent field installation of the valve and accumulator. No other changes indicated.
 
Place of Performance
Address: AFFTC/AFRL, AREA 1-120 & 1-125, Test Stands 1D & 2A, EDWARDS AFB CA
Zip Code: 93524
Country: USA
 
Record
SN00061366-W 20020419/020417213251 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.