MODIFICATION

S -- Construct, Own and Operate a New Transmission Line, Tap, and Substation to Serve Pueblo Chemical Depot Disposal Facility

Notice Date
1/8/2002
 
Notice Type
Modification
 
Contracting Office
US Army Corps of Engineer - Omaha District, 106 S. 15th Street, Omaha, NE 68102-1618
 
ZIP Code
68102-1618
 
Solicitation Number
DACA45-02-R-0010
 
Response Due
1/22/2002
 
Archive Date
2/21/2002
 
Point of Contact
Melvin Vogt, 402-221-4298
 
E-Mail Address
Email your questions to US Army Corps of Engineer - Omaha District
(Mel.E.Vogt@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
NA DESCRIPTION OF WORK: The U.S. Army Corps of Engineers, Omaha District intends to contract by Sole Source procurement the construction, operation and ownership of a new transmission line and tap and a substation, to serve the Pueblo Chemical Depot Disposal Facility (PUCD). The subject transmission line, tap and substation will be owned, operated and maintained by West Plains Energy (WPE), a Division of Utilicorp United. Service is currently provided to PUCD by contract with WPE. The project site is locate d in Northeast corner of the PUCD adjacent to the future site of the chemical demilitarization facility at the Southwest corner. This project is to be constructed prior to the future weapons demilitarization facility advertisement as a part of the chemic al demilitarization support project. The Contractor shall provide all labor, materials, and equipment necessary to install a 115kV transmission line, tap, and substation originating from an existing WPE transmission line running North-South along the east ern edge of the PUCD. The transmission line is 115 kV, wood pole H-frame construction (9 structures) plus a single steel pole tap structure. The length of the line is approximately 7,440 feet from the first to the last structure, over a relatively flat te rrain. The transmission line begins at the first structure located north of the substation. Sufficient cable shall be left at the first structure to permit WPE (Utilicorp United) to extend the line south to the substation dead end structure. The transmi ssion line shall extend eastward to the last structure before tapping the existing 115 kV Department of Transportation Line owned by WPE. The tap pole shall be located and installed with the approval of WPE. Connection between the tap pole and the existi ng 115 kV line shall be by WPE. The tap is approximately mid-span between two structures of the existing line. WPE shall provide the power, Remote Terminal Unit (RTU), and antenna for the tap pole for operation of the two 115 kV motor operated switches, mounted on the tap pole. The motor operators and the switches are to be provided as a part of this contract. The contractor shall install the RTU and antenna. The contractor shall coordinate location of the power feed to the pole with WPE, and shall com ply with WPE requirements. The 115kV transmission line shall extend to a new substation, installed, owned and operated by the constructor that steps voltage down to 13.2kV required to power the Pueblo Chemical Depot Disposal Facility. The substation shall include; a)115kV structures; b) high voltage bussing; c) 115kV circuit switchers; d) 115kV circuit breakers; e) two 12.0/16.OMVA OA/FA cooled 115kV primary to 13.2/7.62kV secondary power transformers; f) 15kV metal enclosed switch gear; g) conduit, ground ing; h) fence; i) grading and access road; and j) other items necessary to own, operate and maintain the substation. The awarded contractor shall coordinate with the Pueblo Chemical Depot (PUCD) facilities engineering office and the Corps of Engineers, resident Office prior to commencement of any construction. Contractor access to G Block area is restricted and personnel access will require escorts and safety training. The current NAICS code applicable to this solicitation is 234920. The applicable sm all business size standard is $27.5 million dollars gross receipts over a three years. View the information of this announcement at http://ebs/nwo/usace/army/mil/ebs/Contract.htm. Point of contact for contractual matters is Mel Vogt at Mel.E.Vogt@usace.a rmy.mil or phone (402) 221-4298, and for technical issues Mr. Alan Ruff at Alan.L.Ruff@nwo02.usace.army.mil or phone (402) 221-3806.
 
Web Link
Army Single Face to Industry
(http://acquisition.army.mil)
 
Place of Performance
Address: US Army Corps of Engineer - Omaha District 106 S. 15th Street, Omaha NE
Zip Code: 68102-1618
Country: US
 
Record
SN20020110/00012572-020109090516 (fbodaily.com)
 
Source
FedBizOpps.gov Link to This Notice
(will not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  © 1994-2020, Loren Data Corp.